Article: Simple interface for capillary electrophoresis-inductively coupled plasma atomic emission spectrometry
Title | Simple interface for capillary electrophoresis-inductively coupled plasma atomic emission spectrometry |
---|---|
Authors | |
Keywords | Detection, electrophoresis Inorganic anions Instrumentation Interfaces, CE-ICP Metal cations Metal complexes |
Issue Date | 2000 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/chroma |
Citation | Journal Of Chromatography A, 2000, v. 891 n. 1, p. 139-148 How to Cite? |
Abstract | A simple interface has been developed to couple capillary electrophoresis (CE) to inductively coupled plasma atomic emission spectrometry (ICP-AES) for metal speciation. A concentric glass nebulizer with elongated tip is used as the CE-ICP interface. The CE capillary is the central tube of the nebulizer. A platinum wire is wrapped across the exit end of the CE capillary to provide electrical connection to the CE power supply. No sheath flow of buffer solution is needed. A simple cooling system has also been developed. A peristaltic pump circulates water through a plastic tube that encloses the section of the CE capillary between the CE instrument and the ICP spectrometer. Characteristics of the CE-ICP interface, e.g., elution time, nebulization and transport efficiency and peak broadening, versus carrier gas flow-rate have been studied. Comparisons to a previous design with the Pt electrode inserted into the end of the CE capillary are made where appropriate. The reproducibility (RSD) in ICP emission intensity of the system is <4%. Detection limits of Cr and Cu are ~5 ng/ml. (C) 2000 Elsevier Science B.V. |
Persistent Identifier | http://hdl.handle.net/10722/68785 |
ISSN | 2023 Impact Factor: 3.8 2023 SCImago Journal Rankings: 0.717 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Deng, B | en_HK |
dc.contributor.author | Chan, WT | en_HK |
dc.date.accessioned | 2010-09-06T06:07:42Z | - |
dc.date.available | 2010-09-06T06:07:42Z | - |
dc.date.issued | 2000 | en_HK |
dc.identifier.citation | Journal Of Chromatography A, 2000, v. 891 n. 1, p. 139-148 | en_HK |
dc.identifier.issn | 0021-9673 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/68785 | - |
dc.description.abstract | A simple interface has been developed to couple capillary electrophoresis (CE) to inductively coupled plasma atomic emission spectrometry (ICP-AES) for metal speciation. A concentric glass nebulizer with elongated tip is used as the CE-ICP interface. The CE capillary is the central tube of the nebulizer. A platinum wire is wrapped across the exit end of the CE capillary to provide electrical connection to the CE power supply. No sheath flow of buffer solution is needed. A simple cooling system has also been developed. A peristaltic pump circulates water through a plastic tube that encloses the section of the CE capillary between the CE instrument and the ICP spectrometer. Characteristics of the CE-ICP interface, e.g., elution time, nebulization and transport efficiency and peak broadening, versus carrier gas flow-rate have been studied. Comparisons to a previous design with the Pt electrode inserted into the end of the CE capillary are made where appropriate. The reproducibility (RSD) in ICP emission intensity of the system is <4%. Detection limits of Cr and Cu are ~5 ng/ml. (C) 2000 Elsevier Science B.V. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/chroma | en_HK |
dc.relation.ispartof | Journal of Chromatography A | en_HK |
dc.rights | Journal of Chromatography A. Copyright © Elsevier BV. | en_HK |
dc.subject | Detection, electrophoresis | en_HK |
dc.subject | Inorganic anions | en_HK |
dc.subject | Instrumentation | en_HK |
dc.subject | Interfaces, CE-ICP | en_HK |
dc.subject | Metal cations | en_HK |
dc.subject | Metal complexes | en_HK |
dc.title | Simple interface for capillary electrophoresis-inductively coupled plasma atomic emission spectrometry | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0021-9673&volume=891&spage=139&epage=148&date=2000&atitle=Simple+interface+for+capillary+electrophoresis-inductively+coupled+plasma+atomic+emission+spectrometry | en_HK |
dc.identifier.email | Chan, WT:wtchan@hku.hk | en_HK |
dc.identifier.authority | Chan, WT=rp00668 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S0021-9673(00)00622-1 | en_HK |
dc.identifier.pmid | 10999633 | - |
dc.identifier.scopus | eid_2-s2.0-0034283705 | en_HK |
dc.identifier.hkuros | 56689 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0034283705&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 891 | en_HK |
dc.identifier.issue | 1 | en_HK |
dc.identifier.spage | 139 | en_HK |
dc.identifier.epage | 148 | en_HK |
dc.identifier.isi | WOS:000089112500012 | - |
dc.publisher.place | Netherlands | en_HK |
dc.identifier.scopusauthorid | Deng, B=14044884000 | en_HK |
dc.identifier.scopusauthorid | Chan, WT=7403918827 | en_HK |
dc.identifier.issnl | 0021-9673 | - |