File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Implant surfaces and design (Working Group 4)

TitleImplant surfaces and design (Working Group 4)
Authors
KeywordsAnimal model
Bone-to-implant contact
Decontamination
Marginal bone level
Oral implants
Osseointegration
Peri-implantitis
Re-osseointegration
Surface coatings
Surface composition
Surface roughness
Surface topography
Issue Date2009
PublisherWiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR
Citation
Clinical Oral Implants Research, 2009, v. 20 SUPPL. 4, p. 228-231 How to Cite?
AbstractIntroduction: The remit of this working group (4) was to update existing knowledge on the effects of implant surface topography, composition and design on bone integration and re-osseointegration. Material and methods: Based on five narrative reviews that were performed following a defined search strategy, clinical implications as well as suggestions for further research have been formulated. Results: The results and conclusions of the review processes in the following papers together with the group consensus, clinical implications and directions for future research are presented: 1. Effects of titanium surface topography on bone integration. 2. Effects of implant surface coatings and composition on bone integration (two reviews). 3. Effects of different implant surfaces and designs on marginal bone level alterations. 4. Re-osseointegration onto previously contaminated implant surfaces. © 2009 John Wiley & Sons A/S.
Persistent Identifierhttp://hdl.handle.net/10722/66768
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.865
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLang, NPen_HK
dc.contributor.authorJepsen, Sen_HK
dc.date.accessioned2010-09-06T05:49:11Z-
dc.date.available2010-09-06T05:49:11Z-
dc.date.issued2009en_HK
dc.identifier.citationClinical Oral Implants Research, 2009, v. 20 SUPPL. 4, p. 228-231en_HK
dc.identifier.issn0905-7161en_HK
dc.identifier.urihttp://hdl.handle.net/10722/66768-
dc.description.abstractIntroduction: The remit of this working group (4) was to update existing knowledge on the effects of implant surface topography, composition and design on bone integration and re-osseointegration. Material and methods: Based on five narrative reviews that were performed following a defined search strategy, clinical implications as well as suggestions for further research have been formulated. Results: The results and conclusions of the review processes in the following papers together with the group consensus, clinical implications and directions for future research are presented: 1. Effects of titanium surface topography on bone integration. 2. Effects of implant surface coatings and composition on bone integration (two reviews). 3. Effects of different implant surfaces and designs on marginal bone level alterations. 4. Re-osseointegration onto previously contaminated implant surfaces. © 2009 John Wiley & Sons A/S.en_HK
dc.languageengen_HK
dc.publisherWiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLRen_HK
dc.relation.ispartofClinical Oral Implants Researchen_HK
dc.subjectAnimal model-
dc.subjectBone-to-implant contact-
dc.subjectDecontamination-
dc.subjectMarginal bone level-
dc.subjectOral implants-
dc.subjectOsseointegration-
dc.subjectPeri-implantitis-
dc.subjectRe-osseointegration-
dc.subjectSurface coatings-
dc.subjectSurface composition-
dc.subjectSurface roughness-
dc.subjectSurface topography-
dc.subject.meshAlveolar Bone Loss - prevention & controlen_HK
dc.subject.meshAnimalsen_HK
dc.subject.meshConsensusen_HK
dc.subject.meshDecontaminationen_HK
dc.subject.meshDental Implantsen_HK
dc.subject.meshDental Prosthesis Designen_HK
dc.subject.meshHumansen_HK
dc.subject.meshOsseointegrationen_HK
dc.subject.meshPeriodontitis - microbiologyen_HK
dc.subject.meshSurface Propertiesen_HK
dc.titleImplant surfaces and design (Working Group 4)en_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0905-7161&volume=20&spage=228&epage=231&date=2009&atitle=Implant+surfaces+and+design+(Working+Group+4)en_HK
dc.identifier.emailLang, NP:nplang@hkucc.hku.hken_HK
dc.identifier.authorityLang, NP=rp00031en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/j.1600-0501.2009.01771.xen_HK
dc.identifier.pmid19663968-
dc.identifier.scopuseid_2-s2.0-68549097985en_HK
dc.identifier.hkuros165550en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-68549097985&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume20en_HK
dc.identifier.issueSUPPL. 4en_HK
dc.identifier.spage228en_HK
dc.identifier.epage231en_HK
dc.identifier.isiWOS:000268296200021-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridLang, NP=7201577367en_HK
dc.identifier.scopusauthoridJepsen, S=7006183412en_HK
dc.identifier.issnl0905-7161-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats