Article: Implant surfaces and design (Working Group 4)
Title | Implant surfaces and design (Working Group 4) |
---|---|
Authors | |
Keywords | Animal model Bone-to-implant contact Decontamination Marginal bone level Oral implants Osseointegration Peri-implantitis Re-osseointegration Surface coatings Surface composition Surface roughness Surface topography |
Issue Date | 2009 |
Publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR |
Citation | Clinical Oral Implants Research, 2009, v. 20 SUPPL. 4, p. 228-231 How to Cite? |
Abstract | Introduction: The remit of this working group (4) was to update existing knowledge on the effects of implant surface topography, composition and design on bone integration and re-osseointegration. Material and methods: Based on five narrative reviews that were performed following a defined search strategy, clinical implications as well as suggestions for further research have been formulated. Results: The results and conclusions of the review processes in the following papers together with the group consensus, clinical implications and directions for future research are presented: 1. Effects of titanium surface topography on bone integration. 2. Effects of implant surface coatings and composition on bone integration (two reviews). 3. Effects of different implant surfaces and designs on marginal bone level alterations. 4. Re-osseointegration onto previously contaminated implant surfaces. © 2009 John Wiley & Sons A/S. |
Persistent Identifier | http://hdl.handle.net/10722/66768 |
ISSN | 2023 Impact Factor: 4.8 2023 SCImago Journal Rankings: 1.865 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lang, NP | en_HK |
dc.contributor.author | Jepsen, S | en_HK |
dc.date.accessioned | 2010-09-06T05:49:11Z | - |
dc.date.available | 2010-09-06T05:49:11Z | - |
dc.date.issued | 2009 | en_HK |
dc.identifier.citation | Clinical Oral Implants Research, 2009, v. 20 SUPPL. 4, p. 228-231 | en_HK |
dc.identifier.issn | 0905-7161 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/66768 | - |
dc.description.abstract | Introduction: The remit of this working group (4) was to update existing knowledge on the effects of implant surface topography, composition and design on bone integration and re-osseointegration. Material and methods: Based on five narrative reviews that were performed following a defined search strategy, clinical implications as well as suggestions for further research have been formulated. Results: The results and conclusions of the review processes in the following papers together with the group consensus, clinical implications and directions for future research are presented: 1. Effects of titanium surface topography on bone integration. 2. Effects of implant surface coatings and composition on bone integration (two reviews). 3. Effects of different implant surfaces and designs on marginal bone level alterations. 4. Re-osseointegration onto previously contaminated implant surfaces. © 2009 John Wiley & Sons A/S. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR | en_HK |
dc.relation.ispartof | Clinical Oral Implants Research | en_HK |
dc.subject | Animal model | - |
dc.subject | Bone-to-implant contact | - |
dc.subject | Decontamination | - |
dc.subject | Marginal bone level | - |
dc.subject | Oral implants | - |
dc.subject | Osseointegration | - |
dc.subject | Peri-implantitis | - |
dc.subject | Re-osseointegration | - |
dc.subject | Surface coatings | - |
dc.subject | Surface composition | - |
dc.subject | Surface roughness | - |
dc.subject | Surface topography | - |
dc.subject.mesh | Alveolar Bone Loss - prevention & control | en_HK |
dc.subject.mesh | Animals | en_HK |
dc.subject.mesh | Consensus | en_HK |
dc.subject.mesh | Decontamination | en_HK |
dc.subject.mesh | Dental Implants | en_HK |
dc.subject.mesh | Dental Prosthesis Design | en_HK |
dc.subject.mesh | Humans | en_HK |
dc.subject.mesh | Osseointegration | en_HK |
dc.subject.mesh | Periodontitis - microbiology | en_HK |
dc.subject.mesh | Surface Properties | en_HK |
dc.title | Implant surfaces and design (Working Group 4) | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0905-7161&volume=20&spage=228&epage=231&date=2009&atitle=Implant+surfaces+and+design+(Working+Group+4) | en_HK |
dc.identifier.email | Lang, NP:nplang@hkucc.hku.hk | en_HK |
dc.identifier.authority | Lang, NP=rp00031 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1111/j.1600-0501.2009.01771.x | en_HK |
dc.identifier.pmid | 19663968 | - |
dc.identifier.scopus | eid_2-s2.0-68549097985 | en_HK |
dc.identifier.hkuros | 165550 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-68549097985&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 20 | en_HK |
dc.identifier.issue | SUPPL. 4 | en_HK |
dc.identifier.spage | 228 | en_HK |
dc.identifier.epage | 231 | en_HK |
dc.identifier.isi | WOS:000268296200021 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Lang, NP=7201577367 | en_HK |
dc.identifier.scopusauthorid | Jepsen, S=7006183412 | en_HK |
dc.identifier.issnl | 0905-7161 | - |