File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1002/elps.200800082
- Scopus: eid_2-s2.0-56849089446
- PMID: 18958889
- WOS: WOS:000261049400005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Determination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatography
Title | Determination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatography |
---|---|
Authors | |
Keywords | Carbonyls Denuder-filter sampling Gradient elution Micellar electrokinetic capillary chromatography |
Issue Date | 2008 |
Publisher | Wiley - V C H Verlag GmbH & Co KGaA |
Citation | Electrophoresis, 2008, v. 29 n. 19, p. 3971-3979 How to Cite? |
Abstract | A new continuous-flow gradient-elution micellar electrokinetic capillary chromatography method is developed for the determination of airborne carbonyls after derivatization with 2,4-dinitrophenylhydrazine. A total of 16 carbonyls can be determined with detection limits ranging from 0.94 to 8.50 mg/L, working range from 4.72 to 346 mg/L, and repeatabilities (relative standard deviation, n=5) from 1.23 to 4.6% or 3.93 to 7.6% for migration time and peak area, respectively. Coupling with denuder-filter sampling, a preliminary survey has been conducted to determine gaseous and particulate carbonyls from air sampled at a roadside station. The method is shown to have sufficient sensitivity for 1-h sampling of ambient carbonyls with detection limits ranging from 0.045 to 1.2 mg/m3 and working range from 0.11 to 43.3 mg/m3 at a flow rate of 10 Lpm. The method requires minimal modification of commercially available capillary electrophoresis equipment and can differentiate gaseous and particulate carbonyls to provide essential information and objective data for adopting effective measures to combat the discharge of carbonyl compounds to the atmosphere. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim. |
Persistent Identifier | http://hdl.handle.net/10722/58364 |
ISSN | 2023 Impact Factor: 3.0 2023 SCImago Journal Rankings: 0.541 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sun, H | en_HK |
dc.contributor.author | Chan, KY | en_HK |
dc.contributor.author | Fung, YS | en_HK |
dc.date.accessioned | 2010-05-31T03:29:01Z | - |
dc.date.available | 2010-05-31T03:29:01Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Electrophoresis, 2008, v. 29 n. 19, p. 3971-3979 | en_HK |
dc.identifier.issn | 0173-0835 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/58364 | - |
dc.description.abstract | A new continuous-flow gradient-elution micellar electrokinetic capillary chromatography method is developed for the determination of airborne carbonyls after derivatization with 2,4-dinitrophenylhydrazine. A total of 16 carbonyls can be determined with detection limits ranging from 0.94 to 8.50 mg/L, working range from 4.72 to 346 mg/L, and repeatabilities (relative standard deviation, n=5) from 1.23 to 4.6% or 3.93 to 7.6% for migration time and peak area, respectively. Coupling with denuder-filter sampling, a preliminary survey has been conducted to determine gaseous and particulate carbonyls from air sampled at a roadside station. The method is shown to have sufficient sensitivity for 1-h sampling of ambient carbonyls with detection limits ranging from 0.045 to 1.2 mg/m3 and working range from 0.11 to 43.3 mg/m3 at a flow rate of 10 Lpm. The method requires minimal modification of commercially available capillary electrophoresis equipment and can differentiate gaseous and particulate carbonyls to provide essential information and objective data for adopting effective measures to combat the discharge of carbonyl compounds to the atmosphere. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Wiley - V C H Verlag GmbH & Co KGaA | en_HK |
dc.relation.ispartof | Electrophoresis | en_HK |
dc.subject | Carbonyls | en_HK |
dc.subject | Denuder-filter sampling | en_HK |
dc.subject | Gradient elution | en_HK |
dc.subject | Micellar electrokinetic capillary chromatography | en_HK |
dc.title | Determination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatography | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0173-0835&volume=29&spage=3971&epage=3979&date=2008&atitle=Determination+of+Gaseous+and+Particulate+Carbonyls+in+AIr+by+Gradient-elution+Micellar+Electrokinetic+Capillary+Chromatography+ | en_HK |
dc.identifier.email | Fung, YS:ysfung@hku.hk | en_HK |
dc.identifier.authority | Fung, YS=rp00697 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1002/elps.200800082 | en_HK |
dc.identifier.pmid | 18958889 | - |
dc.identifier.scopus | eid_2-s2.0-56849089446 | en_HK |
dc.identifier.hkuros | 156284 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-56849089446&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 29 | en_HK |
dc.identifier.issue | 19 | en_HK |
dc.identifier.spage | 3971 | en_HK |
dc.identifier.epage | 3979 | en_HK |
dc.identifier.isi | WOS:000261049400005 | - |
dc.publisher.place | Germany | en_HK |
dc.identifier.scopusauthorid | Sun, H=7404827538 | en_HK |
dc.identifier.scopusauthorid | Chan, KY=25721683600 | en_HK |
dc.identifier.scopusauthorid | Fung, YS=13309754700 | en_HK |
dc.identifier.issnl | 0173-0835 | - |