File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Determination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatography

TitleDetermination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatography
Authors
KeywordsCarbonyls
Denuder-filter sampling
Gradient elution
Micellar electrokinetic capillary chromatography
Issue Date2008
PublisherWiley - V C H Verlag GmbH & Co KGaA
Citation
Electrophoresis, 2008, v. 29 n. 19, p. 3971-3979 How to Cite?
AbstractA new continuous-flow gradient-elution micellar electrokinetic capillary chromatography method is developed for the determination of airborne carbonyls after derivatization with 2,4-dinitrophenylhydrazine. A total of 16 carbonyls can be determined with detection limits ranging from 0.94 to 8.50 mg/L, working range from 4.72 to 346 mg/L, and repeatabilities (relative standard deviation, n=5) from 1.23 to 4.6% or 3.93 to 7.6% for migration time and peak area, respectively. Coupling with denuder-filter sampling, a preliminary survey has been conducted to determine gaseous and particulate carbonyls from air sampled at a roadside station. The method is shown to have sufficient sensitivity for 1-h sampling of ambient carbonyls with detection limits ranging from 0.045 to 1.2 mg/m3 and working range from 0.11 to 43.3 mg/m3 at a flow rate of 10 Lpm. The method requires minimal modification of commercially available capillary electrophoresis equipment and can differentiate gaseous and particulate carbonyls to provide essential information and objective data for adopting effective measures to combat the discharge of carbonyl compounds to the atmosphere. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Persistent Identifierhttp://hdl.handle.net/10722/58364
ISSN
2023 Impact Factor: 3.0
2023 SCImago Journal Rankings: 0.541
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorSun, Hen_HK
dc.contributor.authorChan, KYen_HK
dc.contributor.authorFung, YSen_HK
dc.date.accessioned2010-05-31T03:29:01Z-
dc.date.available2010-05-31T03:29:01Z-
dc.date.issued2008en_HK
dc.identifier.citationElectrophoresis, 2008, v. 29 n. 19, p. 3971-3979en_HK
dc.identifier.issn0173-0835en_HK
dc.identifier.urihttp://hdl.handle.net/10722/58364-
dc.description.abstractA new continuous-flow gradient-elution micellar electrokinetic capillary chromatography method is developed for the determination of airborne carbonyls after derivatization with 2,4-dinitrophenylhydrazine. A total of 16 carbonyls can be determined with detection limits ranging from 0.94 to 8.50 mg/L, working range from 4.72 to 346 mg/L, and repeatabilities (relative standard deviation, n=5) from 1.23 to 4.6% or 3.93 to 7.6% for migration time and peak area, respectively. Coupling with denuder-filter sampling, a preliminary survey has been conducted to determine gaseous and particulate carbonyls from air sampled at a roadside station. The method is shown to have sufficient sensitivity for 1-h sampling of ambient carbonyls with detection limits ranging from 0.045 to 1.2 mg/m3 and working range from 0.11 to 43.3 mg/m3 at a flow rate of 10 Lpm. The method requires minimal modification of commercially available capillary electrophoresis equipment and can differentiate gaseous and particulate carbonyls to provide essential information and objective data for adopting effective measures to combat the discharge of carbonyl compounds to the atmosphere. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.en_HK
dc.languageengen_HK
dc.publisherWiley - V C H Verlag GmbH & Co KGaAen_HK
dc.relation.ispartofElectrophoresisen_HK
dc.subjectCarbonylsen_HK
dc.subjectDenuder-filter samplingen_HK
dc.subjectGradient elutionen_HK
dc.subjectMicellar electrokinetic capillary chromatographyen_HK
dc.titleDetermination of gaseous and particulate carbonyls in air by gradient-elution micellar electrokinetic capillary chromatographyen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0173-0835&volume=29&spage=3971&epage=3979&date=2008&atitle=Determination+of+Gaseous+and+Particulate+Carbonyls+in+AIr+by+Gradient-elution+Micellar+Electrokinetic+Capillary+Chromatography+en_HK
dc.identifier.emailFung, YS:ysfung@hku.hken_HK
dc.identifier.authorityFung, YS=rp00697en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1002/elps.200800082en_HK
dc.identifier.pmid18958889-
dc.identifier.scopuseid_2-s2.0-56849089446en_HK
dc.identifier.hkuros156284en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-56849089446&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume29en_HK
dc.identifier.issue19en_HK
dc.identifier.spage3971en_HK
dc.identifier.epage3979en_HK
dc.identifier.isiWOS:000261049400005-
dc.publisher.placeGermanyen_HK
dc.identifier.scopusauthoridSun, H=7404827538en_HK
dc.identifier.scopusauthoridChan, KY=25721683600en_HK
dc.identifier.scopusauthoridFung, YS=13309754700en_HK
dc.identifier.issnl0173-0835-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats