Article: Vessel extraction under non-uniform illumination: A level set approach
Title | Vessel extraction under non-uniform illumination: A level set approach |
---|---|
Authors | |
Keywords | Active contours Level set method Local contrast enhancement Medical image analysis Nonuniform illumination Vessel extraction |
Issue Date | 2008 |
Publisher | IEEE. |
Citation | Ieee Transactions On Biomedical Engineering, 2008, v. 55 n. 1, p. 358-360 How to Cite? |
Abstract | Vessel extraction is one of the critical tasks in clinical practice. This communication presents a new approach for vessel extraction using a level-set-based active contour by defining a novel local term that takes local image contrast into account. The proposed model not only preserves the performance of the existing models on blurry images, but also overcomes their inability to handle nonuniform illumination. The efficacy of the approach is demonstrated with experiments involving both synthetic images and clinical angiograms. © 2006 IEEE. |
Persistent Identifier | http://hdl.handle.net/10722/57473 |
ISSN | 2023 Impact Factor: 4.4 2023 SCImago Journal Rankings: 1.239 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sum, KW | en_HK |
dc.contributor.author | Cheung, PYS | en_HK |
dc.date.accessioned | 2010-04-12T01:37:33Z | - |
dc.date.available | 2010-04-12T01:37:33Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Ieee Transactions On Biomedical Engineering, 2008, v. 55 n. 1, p. 358-360 | en_HK |
dc.identifier.issn | 0018-9294 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/57473 | - |
dc.description.abstract | Vessel extraction is one of the critical tasks in clinical practice. This communication presents a new approach for vessel extraction using a level-set-based active contour by defining a novel local term that takes local image contrast into account. The proposed model not only preserves the performance of the existing models on blurry images, but also overcomes their inability to handle nonuniform illumination. The efficacy of the approach is demonstrated with experiments involving both synthetic images and clinical angiograms. © 2006 IEEE. | en_HK |
dc.language | eng | en_HK |
dc.publisher | IEEE. | en_HK |
dc.relation.ispartof | IEEE Transactions on Biomedical Engineering | en_HK |
dc.rights | ©2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | - |
dc.subject | Active contours | en_HK |
dc.subject | Level set method | en_HK |
dc.subject | Local contrast enhancement | en_HK |
dc.subject | Medical image analysis | en_HK |
dc.subject | Nonuniform illumination | en_HK |
dc.subject | Vessel extraction | en_HK |
dc.subject.mesh | Algorithms | en_HK |
dc.subject.mesh | Angiography - methods | en_HK |
dc.subject.mesh | Imaging, Three-Dimensional - methods | en_HK |
dc.subject.mesh | Information Storage and Retrieval - methods | en_HK |
dc.subject.mesh | Lighting - methods | en_HK |
dc.title | Vessel extraction under non-uniform illumination: A level set approach | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0018-9294&volume=55&issue=1&spage=358&epage=360&date=2008&atitle=Vessel+extraction+under+non-uniform+illumination:+a+level+set+approach | en_HK |
dc.identifier.email | Cheung, PYS:paul.cheung@hku.hk | en_HK |
dc.identifier.authority | Cheung, PYS=rp00077 | en_HK |
dc.description.nature | published_or_final_version | en_HK |
dc.identifier.doi | 10.1109/TBME.2007.896587 | en_HK |
dc.identifier.pmid | 18232383 | - |
dc.identifier.scopus | eid_2-s2.0-37349048294 | en_HK |
dc.identifier.hkuros | 152464 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-37349048294&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 55 | en_HK |
dc.identifier.issue | 1 | en_HK |
dc.identifier.spage | 358 | en_HK |
dc.identifier.epage | 360 | en_HK |
dc.identifier.isi | WOS:000251908300043 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Sum, KW=16040209400 | en_HK |
dc.identifier.scopusauthorid | Cheung, PYS=7202595335 | en_HK |
dc.identifier.issnl | 0018-9294 | - |