File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/IEMBS.1998.747058
- Scopus: eid_2-s2.0-0032268330
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: Fast measurement of SEP for monitoring spinal cord during scoliosis
Title | Fast measurement of SEP for monitoring spinal cord during scoliosis |
---|---|
Authors | |
Keywords | scoliosis SEP monitoring line interference canceling wavelet analysis |
Issue Date | 1998 |
Publisher | IEEE. |
Citation | The 20th IEEE Engineering in Medicine and Biology Society Conference, Hong Kong, China, 29 October-1 November 1998. In Conference Proceedings, 1998, v. 4, p. 2239-2242 How to Cite? |
Abstract | Recently there has been considerable interest in the use of somatosensory evoked potential (SEP) for monitoring the functional integrity of the spinal cord during surgery such as scoliosis. This paper describes a monitoring system and signal processing algorithms, which consist of an artificial neural network filter and a wavelet signal enhancer developed to enhance the signal-to-noise ratio (SNR) of surface recorded SEP. Our system allows fast detection of change in SEP's peak latency, amplitude and signal waveform, which are the main parameters of interest during intra-operative procedures. |
Persistent Identifier | http://hdl.handle.net/10722/46128 |
ISSN | 2023 SCImago Journal Rankings: 0.340 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fung, KSM | en_HK |
dc.contributor.author | Du, MH | en_HK |
dc.contributor.author | Liu, WQ | en_HK |
dc.contributor.author | Chan, FHY | en_HK |
dc.contributor.author | Lam, FK | en_HK |
dc.contributor.author | Luk, DK | en_HK |
dc.contributor.author | Hu, Y | en_HK |
dc.date.accessioned | 2007-10-30T06:43:07Z | - |
dc.date.available | 2007-10-30T06:43:07Z | - |
dc.date.issued | 1998 | en_HK |
dc.identifier.citation | The 20th IEEE Engineering in Medicine and Biology Society Conference, Hong Kong, China, 29 October-1 November 1998. In Conference Proceedings, 1998, v. 4, p. 2239-2242 | en_HK |
dc.identifier.issn | 0589-1019 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/46128 | - |
dc.description.abstract | Recently there has been considerable interest in the use of somatosensory evoked potential (SEP) for monitoring the functional integrity of the spinal cord during surgery such as scoliosis. This paper describes a monitoring system and signal processing algorithms, which consist of an artificial neural network filter and a wavelet signal enhancer developed to enhance the signal-to-noise ratio (SNR) of surface recorded SEP. Our system allows fast detection of change in SEP's peak latency, amplitude and signal waveform, which are the main parameters of interest during intra-operative procedures. | en_HK |
dc.format.extent | 360273 bytes | - |
dc.format.extent | 13817 bytes | - |
dc.format.extent | 8841 bytes | - |
dc.format.mimetype | application/pdf | - |
dc.format.mimetype | text/plain | - |
dc.format.mimetype | text/plain | - |
dc.language | eng | en_HK |
dc.publisher | IEEE. | en_HK |
dc.relation.ispartof | IEEE Engineering in Medicine and Biology Society Conference Proceedings | en_HK |
dc.rights | ©1998 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | - |
dc.subject | scoliosis | en_HK |
dc.subject | SEP monitoring | en_HK |
dc.subject | line interference canceling | en_HK |
dc.subject | wavelet analysis | en_HK |
dc.title | Fast measurement of SEP for monitoring spinal cord during scoliosis | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1557-170X&volume=4&spage=2239&epage=2242&date=1998&atitle=Fast+measurement+of+SEP+for+monitoring+spinal+cord+during+scoliosis | en_HK |
dc.identifier.email | Luk, DK:hcm21000@hku.hk | en_HK |
dc.identifier.email | Hu, Y:yhud@hku.hk | en_HK |
dc.identifier.authority | Luk, DK=rp00333 | en_HK |
dc.identifier.authority | Hu, Y=rp00432 | en_HK |
dc.description.nature | published_or_final_version | en_HK |
dc.identifier.doi | 10.1109/IEMBS.1998.747058 | en_HK |
dc.identifier.scopus | eid_2-s2.0-0032268330 | en_HK |
dc.identifier.hkuros | 45413 | - |
dc.identifier.volume | 4 | en_HK |
dc.identifier.spage | 2239 | en_HK |
dc.identifier.epage | 2242 | en_HK |
dc.publisher.place | United States | en_HK |
dc.description.other | The 20th IEEE Engineering in Medicine and Biology Society Conference Proceedings, Hong Kong, China, 29 October - 1 November 1998, v. 4, p. 2239-2242 | - |
dc.identifier.scopusauthorid | Fung, KSM=55160081400 | en_HK |
dc.identifier.scopusauthorid | Du, MH=7201997901 | en_HK |
dc.identifier.scopusauthorid | Liu, WQ=7407341280 | en_HK |
dc.identifier.scopusauthorid | Chan, FHY=7202586429 | en_HK |
dc.identifier.scopusauthorid | Lam, FK=7102075939 | en_HK |
dc.identifier.scopusauthorid | Luk, DK=7201921573 | en_HK |
dc.identifier.scopusauthorid | Hu, Y=7407116091 | en_HK |
dc.customcontrol.immutable | sml 170512 amended | - |
dc.identifier.issnl | 0589-1019 | - |