TitleA real-time monitor using wavelet analysis of the Doppler heart sound for the detection of venous air embolism
Authors
KeywordsElectronics
Issue Date1997
PublisherIEEE.
Citation
IEEE International Symposium on Circuits and Systems Proceedings, Hong Kong, China, 9-12 June 1997, v. 1, p. 189-192 How to Cite?
AbstractA fast detection algorithm for venous air embolism (VAE) was developed and implemented as a real-time monitor for detecting embolic heart sound and estimating embolic air volume. Its performance was evaluated under bolus injection of sub-clinical (0.0l to 0.80 ml) and continuous infusion of clinically significant (0.80 to 9.60 ml) air volumes in anaesthetized dogs. The clinically significant air emboli could be estimated based on the calibration curve obtained during sub-clinical VAE for a subject. The monitor also kept track of the cumulative embolic air volumes and alerted the anaesthetists once a predefined clinically significant embolic air volume was reached. As both humans and dogs share similar physiological conditions, our monitor for dogs are expected to be applicable to humans.
Persistent Identifierhttp://hdl.handle.net/10722/46011
ISSN

 

DC FieldValueLanguage
dc.contributor.authorChan, BCBen_HK
dc.contributor.authorChan, FHYen_HK
dc.contributor.authorLui, PWen_HK
dc.contributor.authorPoon, PWFen_HK
dc.contributor.authorLam, FKen_HK
dc.contributor.authorWang, Hen_HK
dc.date.accessioned2007-10-30T06:40:35Z-
dc.date.available2007-10-30T06:40:35Z-
dc.date.issued1997en_HK
dc.identifier.citationIEEE International Symposium on Circuits and Systems Proceedings, Hong Kong, China, 9-12 June 1997, v. 1, p. 189-192en_HK
dc.identifier.issn0271-4302en_HK
dc.identifier.urihttp://hdl.handle.net/10722/46011-
dc.description.abstractA fast detection algorithm for venous air embolism (VAE) was developed and implemented as a real-time monitor for detecting embolic heart sound and estimating embolic air volume. Its performance was evaluated under bolus injection of sub-clinical (0.0l to 0.80 ml) and continuous infusion of clinically significant (0.80 to 9.60 ml) air volumes in anaesthetized dogs. The clinically significant air emboli could be estimated based on the calibration curve obtained during sub-clinical VAE for a subject. The monitor also kept track of the cumulative embolic air volumes and alerted the anaesthetists once a predefined clinically significant embolic air volume was reached. As both humans and dogs share similar physiological conditions, our monitor for dogs are expected to be applicable to humans.en_HK
dc.format.extent459073 bytes-
dc.format.extent13817 bytes-
dc.format.extent8841 bytes-
dc.format.mimetypeapplication/pdf-
dc.format.mimetypetext/plain-
dc.format.mimetypetext/plain-
dc.languageengen_HK
dc.publisherIEEE.en_HK
dc.rights©1997 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.-
dc.subjectElectronicsen_HK
dc.titleA real-time monitor using wavelet analysis of the Doppler heart sound for the detection of venous air embolismen_HK
dc.typeConference_Paperen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0271-4302&volume=1&spage=189&epage=192&date=1997&atitle=A+real-time+monitor+using+wavelet+analysis+of+the+Doppler+heart+sound+for+the+detection+of+venous+air+embolismen_HK
dc.description.naturepublished_or_final_versionen_HK
dc.identifier.doi10.1109/ISCAS.1997.608662en_HK
dc.identifier.hkuros27190-
dc.identifier.issnl0271-4302-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats