File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/IEMBS.2005.1616444
- Scopus: eid_2-s2.0-33846907419
- PMID: 17282213
- Find via
Supplementary
-
Bookmarks:
- CiteULike: 1
- Citations:
- Appears in Collections:
Conference Paper: Image registration in myocardial perfusion MRI
Title | Image registration in myocardial perfusion MRI |
---|---|
Authors | |
Keywords | Medical sciences Computer applications |
Issue Date | 2005 |
Publisher | IEEE. |
Citation | The 27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005), Shanghai, China, 1-4 September 2005. In Conference Proceedings, 2005, v. 7, p. 453-454 How to Cite? |
Abstract | In clinical first-pass myocardial perfusion studies, physiological and patient motions are inevitable. Such motions impair the sensitivity and reliability in assessing myocardial perfusion abnormalities. The current study aims to correct the misregistration of myocardium during first-pass perfusion imaging by using a normalized mutual information approach. Multi-slice registrations were performed in 15 sets of clinical data sets. The proposed registration procedure was found to be fairly robust. With such registration, ROI time courses from normal myocardium and infarcted myocardium were improved, offering potential to quantify myocardial perfusion parameters in a more reliable manner. © 2005 IEEE. |
Persistent Identifier | http://hdl.handle.net/10722/45726 |
ISSN | 2023 SCImago Journal Rankings: 0.340 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wong, KK | en_HK |
dc.contributor.author | Wu, EX | en_HK |
dc.contributor.author | Ng, MC | en_HK |
dc.contributor.author | Wu, Y | en_HK |
dc.contributor.author | Tse, HF | en_HK |
dc.contributor.author | Lau, CP | en_HK |
dc.contributor.author | Lo, G | en_HK |
dc.contributor.author | Yang, ES | en_HK |
dc.date.accessioned | 2007-10-30T06:33:49Z | - |
dc.date.available | 2007-10-30T06:33:49Z | - |
dc.date.issued | 2005 | en_HK |
dc.identifier.citation | The 27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005), Shanghai, China, 1-4 September 2005. In Conference Proceedings, 2005, v. 7, p. 453-454 | en_HK |
dc.identifier.issn | 0589-1019 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/45726 | - |
dc.description.abstract | In clinical first-pass myocardial perfusion studies, physiological and patient motions are inevitable. Such motions impair the sensitivity and reliability in assessing myocardial perfusion abnormalities. The current study aims to correct the misregistration of myocardium during first-pass perfusion imaging by using a normalized mutual information approach. Multi-slice registrations were performed in 15 sets of clinical data sets. The proposed registration procedure was found to be fairly robust. With such registration, ROI time courses from normal myocardium and infarcted myocardium were improved, offering potential to quantify myocardial perfusion parameters in a more reliable manner. © 2005 IEEE. | en_HK |
dc.format.extent | 213464 bytes | - |
dc.format.extent | 1775 bytes | - |
dc.format.extent | 2851 bytes | - |
dc.format.mimetype | application/pdf | - |
dc.format.mimetype | text/plain | - |
dc.format.mimetype | text/plain | - |
dc.language | eng | en_HK |
dc.publisher | IEEE. | en_HK |
dc.relation.ispartof | Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings | en_HK |
dc.rights | ©2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. | - |
dc.subject | Medical sciences | en_HK |
dc.subject | Computer applications | en_HK |
dc.title | Image registration in myocardial perfusion MRI | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1557-170X&volume=&spage=453&epage=454&date=2005&atitle=Image+Registration+in+Myocardial+Perfusion+MRI | en_HK |
dc.identifier.email | Wu, EX: ewu1@hkucc.hku.hk | en_HK |
dc.identifier.email | Tse, HF: hftse@hkucc.hku.hk | en_HK |
dc.identifier.email | Yang, ES:esyang@eee.hku.hk | en_HK |
dc.identifier.authority | Wu, EX=rp00193 | en_HK |
dc.identifier.authority | Tse, HF=rp00428 | en_HK |
dc.identifier.authority | Yang, ES=rp00199 | en_HK |
dc.description.nature | published_or_final_version | en_HK |
dc.identifier.doi | 10.1109/IEMBS.2005.1616444 | en_HK |
dc.identifier.pmid | 17282213 | - |
dc.identifier.scopus | eid_2-s2.0-33846907419 | en_HK |
dc.identifier.hkuros | 119805 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-33846907419&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 7 | en_HK |
dc.identifier.spage | 453 | en_HK |
dc.identifier.epage | 454 | en_HK |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Wong, KK=7404759210 | en_HK |
dc.identifier.scopusauthorid | Wu, EX=7202128034 | en_HK |
dc.identifier.scopusauthorid | Ng, MC=7202076279 | en_HK |
dc.identifier.scopusauthorid | Wu, Y=8940205500 | en_HK |
dc.identifier.scopusauthorid | Tse, HF=7006070805 | en_HK |
dc.identifier.scopusauthorid | Lau, CP=7401968501 | en_HK |
dc.identifier.scopusauthorid | Lo, G=7101880732 | en_HK |
dc.identifier.scopusauthorid | Yang, ES=7202021229 | en_HK |
dc.identifier.citeulike | 7106830 | - |
dc.customcontrol.immutable | sml 160114 - merged | - |
dc.identifier.issnl | 0589-1019 | - |