Conference Paper: Image registration in myocardial perfusion MRI

TitleImage registration in myocardial perfusion MRI
Authors
KeywordsMedical sciences
Computer applications
Issue Date2005
PublisherIEEE.
Citation
The 27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005), Shanghai, China, 1-4 September 2005. In Conference Proceedings, 2005, v. 7, p. 453-454 How to Cite?
AbstractIn clinical first-pass myocardial perfusion studies, physiological and patient motions are inevitable. Such motions impair the sensitivity and reliability in assessing myocardial perfusion abnormalities. The current study aims to correct the misregistration of myocardium during first-pass perfusion imaging by using a normalized mutual information approach. Multi-slice registrations were performed in 15 sets of clinical data sets. The proposed registration procedure was found to be fairly robust. With such registration, ROI time courses from normal myocardium and infarcted myocardium were improved, offering potential to quantify myocardial perfusion parameters in a more reliable manner. © 2005 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/45726
ISSN
2023 SCImago Journal Rankings: 0.340
References

 

DC FieldValueLanguage
dc.contributor.authorWong, KKen_HK
dc.contributor.authorWu, EXen_HK
dc.contributor.authorNg, MCen_HK
dc.contributor.authorWu, Yen_HK
dc.contributor.authorTse, HFen_HK
dc.contributor.authorLau, CPen_HK
dc.contributor.authorLo, Gen_HK
dc.contributor.authorYang, ESen_HK
dc.date.accessioned2007-10-30T06:33:49Z-
dc.date.available2007-10-30T06:33:49Z-
dc.date.issued2005en_HK
dc.identifier.citationThe 27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005), Shanghai, China, 1-4 September 2005. In Conference Proceedings, 2005, v. 7, p. 453-454en_HK
dc.identifier.issn0589-1019en_HK
dc.identifier.urihttp://hdl.handle.net/10722/45726-
dc.description.abstractIn clinical first-pass myocardial perfusion studies, physiological and patient motions are inevitable. Such motions impair the sensitivity and reliability in assessing myocardial perfusion abnormalities. The current study aims to correct the misregistration of myocardium during first-pass perfusion imaging by using a normalized mutual information approach. Multi-slice registrations were performed in 15 sets of clinical data sets. The proposed registration procedure was found to be fairly robust. With such registration, ROI time courses from normal myocardium and infarcted myocardium were improved, offering potential to quantify myocardial perfusion parameters in a more reliable manner. © 2005 IEEE.en_HK
dc.format.extent213464 bytes-
dc.format.extent1775 bytes-
dc.format.extent2851 bytes-
dc.format.mimetypeapplication/pdf-
dc.format.mimetypetext/plain-
dc.format.mimetypetext/plain-
dc.languageengen_HK
dc.publisherIEEE.en_HK
dc.relation.ispartofAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedingsen_HK
dc.rights©2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.-
dc.subjectMedical sciencesen_HK
dc.subjectComputer applicationsen_HK
dc.titleImage registration in myocardial perfusion MRIen_HK
dc.typeConference_Paperen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1557-170X&volume=&spage=453&epage=454&date=2005&atitle=Image+Registration+in+Myocardial+Perfusion+MRIen_HK
dc.identifier.emailWu, EX: ewu1@hkucc.hku.hken_HK
dc.identifier.emailTse, HF: hftse@hkucc.hku.hken_HK
dc.identifier.emailYang, ES:esyang@eee.hku.hken_HK
dc.identifier.authorityWu, EX=rp00193en_HK
dc.identifier.authorityTse, HF=rp00428en_HK
dc.identifier.authorityYang, ES=rp00199en_HK
dc.description.naturepublished_or_final_versionen_HK
dc.identifier.doi10.1109/IEMBS.2005.1616444en_HK
dc.identifier.pmid17282213-
dc.identifier.scopuseid_2-s2.0-33846907419en_HK
dc.identifier.hkuros119805-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33846907419&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume7en_HK
dc.identifier.spage453en_HK
dc.identifier.epage454en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridWong, KK=7404759210en_HK
dc.identifier.scopusauthoridWu, EX=7202128034en_HK
dc.identifier.scopusauthoridNg, MC=7202076279en_HK
dc.identifier.scopusauthoridWu, Y=8940205500en_HK
dc.identifier.scopusauthoridTse, HF=7006070805en_HK
dc.identifier.scopusauthoridLau, CP=7401968501en_HK
dc.identifier.scopusauthoridLo, G=7101880732en_HK
dc.identifier.scopusauthoridYang, ES=7202021229en_HK
dc.identifier.citeulike7106830-
dc.customcontrol.immutablesml 160114 - merged-
dc.identifier.issnl0589-1019-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats