TitleSynthesis of input-rectifierless AC/DC converters
Authors
KeywordsAC/DC converter
Circuit topology
Control
Dc/dc converter
Rectifier
Issue Date2004
PublisherIEEE.
Citation
Ieee Transactions On Power Electronics, 2004, v. 19 n. 1, p. 176-182 How to Cite?
AbstractThis paper discusses the basic construction procedure and topological possibilities of creating ac/dc converters out of simple dc/dc converters. It is shown that two separately controlled dc/dc converters are sufficient for producing a regulated dc output and shaping the input current, from an ac voltage source, without the need for input rectifiers. Some design constraints are discussed, emanating from the limitation of the conversion ratios that can be achieved by particular dc/dc converters. Selected topologies are verified experimentally. This kind of rectifierless converters find applications in airborne power supplies where zero-crossing distortions are significant because of the inevitable phase-lead effect of the input rectifier bridge.
Persistent Identifierhttp://hdl.handle.net/10722/42972
ISSN
2021 Impact Factor: 5.967
2020 SCImago Journal Rankings: 2.159
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLiu, CPen_HK
dc.contributor.authorTse, CKen_HK
dc.contributor.authorPoon, NKen_HK
dc.contributor.authorPong, BMHen_HK
dc.contributor.authorLai, YMen_HK
dc.date.accessioned2007-03-23T04:35:46Z-
dc.date.available2007-03-23T04:35:46Z-
dc.date.issued2004en_HK
dc.identifier.citationIeee Transactions On Power Electronics, 2004, v. 19 n. 1, p. 176-182en_HK
dc.identifier.issn0885-8993en_HK
dc.identifier.urihttp://hdl.handle.net/10722/42972-
dc.description.abstractThis paper discusses the basic construction procedure and topological possibilities of creating ac/dc converters out of simple dc/dc converters. It is shown that two separately controlled dc/dc converters are sufficient for producing a regulated dc output and shaping the input current, from an ac voltage source, without the need for input rectifiers. Some design constraints are discussed, emanating from the limitation of the conversion ratios that can be achieved by particular dc/dc converters. Selected topologies are verified experimentally. This kind of rectifierless converters find applications in airborne power supplies where zero-crossing distortions are significant because of the inevitable phase-lead effect of the input rectifier bridge.en_HK
dc.format.extent338368 bytes-
dc.format.extent26624 bytes-
dc.format.mimetypeapplication/pdf-
dc.format.mimetypeapplication/msword-
dc.languageengen_HK
dc.publisherIEEE.en_HK
dc.relation.ispartofIEEE Transactions on Power Electronicsen_HK
dc.rights©2004 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.-
dc.subjectAC/DC converteren_HK
dc.subjectCircuit topologyen_HK
dc.subjectControlen_HK
dc.subjectDc/dc converteren_HK
dc.subjectRectifieren_HK
dc.titleSynthesis of input-rectifierless AC/DC convertersen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0885-8993&volume=19&issue=1&spage=176&epage=182&date=2004&atitle=Synthesis+of+input-rectifierless+AC/DC+convertersen_HK
dc.identifier.emailPong, BMH:mhp@eee.hku.hken_HK
dc.identifier.authorityPong, BMH=rp00163en_HK
dc.description.naturepublished_or_final_versionen_HK
dc.identifier.doi10.1109/TPEL.2003.820577en_HK
dc.identifier.scopuseid_2-s2.0-0742321336en_HK
dc.identifier.hkuros90441-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0742321336&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume19en_HK
dc.identifier.issue1en_HK
dc.identifier.spage176en_HK
dc.identifier.epage182en_HK
dc.identifier.isiWOS:000188260300020-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridLiu, CP=7409795443en_HK
dc.identifier.scopusauthoridTse, CK=7103295097en_HK
dc.identifier.scopusauthoridPoon, NK=7003278153en_HK
dc.identifier.scopusauthoridPong, BMH=7003449364en_HK
dc.identifier.scopusauthoridLai, YM=7401512093en_HK
dc.identifier.issnl0885-8993-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats