Article: Technique development of 3D dynamic CS-EPSI for hyperpolarized13C pyruvate MR molecular imaging of human prostate cancer

TitleTechnique development of 3D dynamic CS-EPSI for hyperpolarized<sup>13</sup>C pyruvate MR molecular imaging of human prostate cancer
Authors
Keywordshyperpolarized C-13 pyruvate
human prostate cancer
3D dynamic imaging
Issue Date2018
Citation
Magnetic Resonance in Medicine, 2018, v. 80, n. 5, p. 2062-2072 How to Cite?
Abstract© 2018 International Society for Magnetic Resonance in Medicine Purpose: The purpose of this study was to develop a new 3D dynamic carbon-13 compressed sensing echoplanar spectroscopic imaging (EPSI) MR sequence and test it in phantoms, animal models, and then in prostate cancer patients to image the metabolic conversion of hyperpolarized [1-13C]pyruvate to [1-13C]lactate with whole gland coverage at high spatial and temporal resolution. Methods: A 3D dynamic compressed sensing (CS)-EPSI sequence with spectral–spatial excitation was designed to meet the required spatial coverage, time and spatial resolution, and RF limitations of the 3T MR scanner for its clinical translation for prostate cancer patient imaging. After phantom testing, animal studies were performed in rats and transgenic mice with prostate cancers. For patient studies, a GE SPINlab polarizer (GE Healthcare, Waukesha, WI) was used to produce hyperpolarized sterile GMP [1-13C]pyruvate. 3D dynamic13C CS-EPSI data were acquired starting 5 s after injection throughout the gland with a spatial resolution of 0.5 cm3, 18 time frames, 2-s temporal resolution, and 36 s total acquisition time. Results: Through preclinical testing, the 3D CS-EPSI sequence developed in this project was shown to provide the desired spectral, temporal, and spatial 5D HP13C MR data. In human studies, the 3D dynamic HP CS-EPSI approach provided first-ever simultaneously volumetric and dynamic images of the LDH-catalyzed conversion of [1-13C]pyruvate to [1-13C]lactate in a biopsy-proven prostate cancer patient with full gland coverage. Conclusion: The results demonstrate the feasibility to characterize prostate cancer metabolism in animals, and now patients using this new 3D dynamic HP MR technique to measure kPL, the kinetic rate constant of [1-13C]pyruvate to [1-13C]lactate conversion.
Persistent Identifierhttp://hdl.handle.net/10722/265738
ISSN
2021 Impact Factor: 3.737
2020 SCImago Journal Rankings: 1.696
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChen, Hsin Yu-
dc.contributor.authorLarson, Peder E.Z.-
dc.contributor.authorGordon, Jeremy W.-
dc.contributor.authorBok, Robert A.-
dc.contributor.authorFerrone, Marcus-
dc.contributor.authorvan Criekinge, Mark-
dc.contributor.authorCarvajal, Lucas-
dc.contributor.authorCao, Peng-
dc.contributor.authorPauly, John M.-
dc.contributor.authorKerr, Adam B.-
dc.contributor.authorPark, Ilwoo-
dc.contributor.authorSlater, James B.-
dc.contributor.authorNelson, Sarah J.-
dc.contributor.authorMunster, Pamela N.-
dc.contributor.authorAggarwal, Rahul-
dc.contributor.authorKurhanewicz, John-
dc.contributor.authorVigneron, Daniel B.-
dc.date.accessioned2018-12-03T01:21:33Z-
dc.date.available2018-12-03T01:21:33Z-
dc.date.issued2018-
dc.identifier.citationMagnetic Resonance in Medicine, 2018, v. 80, n. 5, p. 2062-2072-
dc.identifier.issn0740-3194-
dc.identifier.urihttp://hdl.handle.net/10722/265738-
dc.description.abstract© 2018 International Society for Magnetic Resonance in Medicine Purpose: The purpose of this study was to develop a new 3D dynamic carbon-13 compressed sensing echoplanar spectroscopic imaging (EPSI) MR sequence and test it in phantoms, animal models, and then in prostate cancer patients to image the metabolic conversion of hyperpolarized [1-13C]pyruvate to [1-13C]lactate with whole gland coverage at high spatial and temporal resolution. Methods: A 3D dynamic compressed sensing (CS)-EPSI sequence with spectral–spatial excitation was designed to meet the required spatial coverage, time and spatial resolution, and RF limitations of the 3T MR scanner for its clinical translation for prostate cancer patient imaging. After phantom testing, animal studies were performed in rats and transgenic mice with prostate cancers. For patient studies, a GE SPINlab polarizer (GE Healthcare, Waukesha, WI) was used to produce hyperpolarized sterile GMP [1-13C]pyruvate. 3D dynamic13C CS-EPSI data were acquired starting 5 s after injection throughout the gland with a spatial resolution of 0.5 cm3, 18 time frames, 2-s temporal resolution, and 36 s total acquisition time. Results: Through preclinical testing, the 3D CS-EPSI sequence developed in this project was shown to provide the desired spectral, temporal, and spatial 5D HP13C MR data. In human studies, the 3D dynamic HP CS-EPSI approach provided first-ever simultaneously volumetric and dynamic images of the LDH-catalyzed conversion of [1-13C]pyruvate to [1-13C]lactate in a biopsy-proven prostate cancer patient with full gland coverage. Conclusion: The results demonstrate the feasibility to characterize prostate cancer metabolism in animals, and now patients using this new 3D dynamic HP MR technique to measure kPL, the kinetic rate constant of [1-13C]pyruvate to [1-13C]lactate conversion.-
dc.languageeng-
dc.relation.ispartofMagnetic Resonance in Medicine-
dc.subjecthyperpolarized C-13 pyruvate-
dc.subjecthuman prostate cancer-
dc.subject3D dynamic imaging-
dc.titleTechnique development of 3D dynamic CS-EPSI for hyperpolarized<sup>13</sup>C pyruvate MR molecular imaging of human prostate cancer-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1002/mrm.27179-
dc.identifier.scopuseid_2-s2.0-85044431860-
dc.identifier.volume80-
dc.identifier.issue5-
dc.identifier.spage2062-
dc.identifier.epage2072-
dc.identifier.eissn1522-2594-
dc.identifier.isiWOS:000448872700027-
dc.identifier.issnl0740-3194-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats