File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Frames of reference for biological motion and face perception

TitleFrames of reference for biological motion and face perception
Authors
KeywordsFace perception
Biological motion
Reference frames
Issue Date2010
Citation
Journal of Vision, 2010, v. 10, n. 6 How to Cite?
AbstractWe investigated the roles of egocentric, gravitational, and visual environmental reference frames for face and biological motion perception. We tested observers on face and biological motion tasks while orienting the visual environment and the observer independently with respect to gravity using the York Tumbling Room. The relative contribution of each reference frame was assessed by arranging pairs of frames to be either aligned or opposed to each other while rendering the third uninformative by orienting it sideways relative to the stimulus. The perception of both biological motion and faces were optimal when the stimulus was aligned with egocentric coordinates. However, when the egocentric reference frame was rendered uninformative, the perception of biological motion, but not faces, relied more on stimulus alignment with gravity rather than the visual environment. © ARVO.
Persistent Identifierhttp://hdl.handle.net/10722/242611
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChang, Dorita H F-
dc.contributor.authorHarris, Laurence R.-
dc.contributor.authorTroje, Nikolaus F.-
dc.date.accessioned2017-08-10T10:51:07Z-
dc.date.available2017-08-10T10:51:07Z-
dc.date.issued2010-
dc.identifier.citationJournal of Vision, 2010, v. 10, n. 6-
dc.identifier.urihttp://hdl.handle.net/10722/242611-
dc.description.abstractWe investigated the roles of egocentric, gravitational, and visual environmental reference frames for face and biological motion perception. We tested observers on face and biological motion tasks while orienting the visual environment and the observer independently with respect to gravity using the York Tumbling Room. The relative contribution of each reference frame was assessed by arranging pairs of frames to be either aligned or opposed to each other while rendering the third uninformative by orienting it sideways relative to the stimulus. The perception of both biological motion and faces were optimal when the stimulus was aligned with egocentric coordinates. However, when the egocentric reference frame was rendered uninformative, the perception of biological motion, but not faces, relied more on stimulus alignment with gravity rather than the visual environment. © ARVO.-
dc.languageeng-
dc.relation.ispartofJournal of Vision-
dc.subjectFace perception-
dc.subjectBiological motion-
dc.subjectReference frames-
dc.titleFrames of reference for biological motion and face perception-
dc.typeArticle-
dc.description.naturelink_to_OA_fulltext-
dc.identifier.doi10.1167/10.6.22-
dc.identifier.pmid20884571-
dc.identifier.scopuseid_2-s2.0-79955156206-
dc.identifier.volume10-
dc.identifier.issue6-
dc.identifier.spagenull-
dc.identifier.epagenull-
dc.identifier.eissn1534-7362-
dc.identifier.isiWOS:000280551700022-
dc.identifier.issnl1534-7362-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats