Conference Paper: Simultaneous Nyquist ghost and Geometric distortion correction based on reversed readout strategy in EPI
Title | Simultaneous Nyquist ghost and Geometric distortion correction based on reversed readout strategy in EPI |
---|---|
Authors | |
Issue Date | 2014 |
Publisher | ISMRM-ESMRMB 2014. |
Citation | The 2014 joint ISMRM-ESMRMB Annual Meeting, Milano, Italy, 10-16 May 2014. How to Cite? |
Abstract | Echo planar imaging (EPI) has been used in many applications such as fMRI and DWI. However, EPI images are prone to Nyquist ghost and geometric distortion.In this study, we proposed a new scheme based on reversed readout strategy to correct both Nyquist ghost and geometric distortion artifacts on EPI images simultaneously. We have demonstrated the proposed method can effectively remove Nyquist ghost and correct geometric distortion both in phantom and rat brain. This method may be paticularly suited for dynamic EPI protocols such as fMRI and dynamic contrast-enhanced MRI applications. |
Description | Traditional Poster Session - Pulse Sequences & Reconstruction: Artifacts Correction: no. 1640 |
Persistent Identifier | http://hdl.handle.net/10722/204144 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Xie, VB | en_US |
dc.contributor.author | Tsang, AHW | en_US |
dc.contributor.author | Wu, EX | en_US |
dc.date.accessioned | 2014-09-19T20:06:50Z | - |
dc.date.available | 2014-09-19T20:06:50Z | - |
dc.date.issued | 2014 | en_US |
dc.identifier.citation | The 2014 joint ISMRM-ESMRMB Annual Meeting, Milano, Italy, 10-16 May 2014. | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/204144 | - |
dc.description | Traditional Poster Session - Pulse Sequences & Reconstruction: Artifacts Correction: no. 1640 | - |
dc.description.abstract | Echo planar imaging (EPI) has been used in many applications such as fMRI and DWI. However, EPI images are prone to Nyquist ghost and geometric distortion.In this study, we proposed a new scheme based on reversed readout strategy to correct both Nyquist ghost and geometric distortion artifacts on EPI images simultaneously. We have demonstrated the proposed method can effectively remove Nyquist ghost and correct geometric distortion both in phantom and rat brain. This method may be paticularly suited for dynamic EPI protocols such as fMRI and dynamic contrast-enhanced MRI applications. | - |
dc.language | eng | en_US |
dc.publisher | ISMRM-ESMRMB 2014. | - |
dc.relation.ispartof | ISMRM-ESMRMB Annual Meeting 2014 | en_US |
dc.title | Simultaneous Nyquist ghost and Geometric distortion correction based on reversed readout strategy in EPI | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Tsang, AHW: ahwtsang@hku.hk | en_US |
dc.identifier.email | Wu, EX: ewu1@hkucc.hku.hk | - |
dc.identifier.authority | Wu, EX=rp00193 | en_US |
dc.description.nature | link_to_OA_fulltext | - |
dc.identifier.hkuros | 240613 | en_US |