Article: A microcomputer package for real-time skin conductance response analysis
Title | A microcomputer package for real-time skin conductance response analysis |
---|---|
Authors | |
Issue Date | 1983 |
Publisher | Psychonomic Society, Inc. The Journal's web site is located at http://www.psychonomic.org/BRMIC/ |
Citation | Behavior Research Methods & Instrumentation, 1983, v. 15 n. 6, p. 591-593 How to Cite? |
Abstract | A suite of programs has been developed to acquire data from a commercially available, highquality skin conductance meter, via a standard IEEE bus, on an Apple II or Apple lie microcomputer. These programs score and analyze stimulus-evoked skin conductance responses in a preset time window, and store the resultant data on disk, if required. Facilities for a manual override of the automatic scoring routine are available. The setup offers a method of scoring data as they are acquired; it uses currently recommended standards for skin conductance analysis and allows a high magnification of responses, without any need for continual monitoring, because of hardware facilities that automatically "back-off" a subject's tonic skin conductance level. © 1983 Psychonomic Society, Inc. |
Persistent Identifier | http://hdl.handle.net/10722/178248 |
ISSN | 2023 Impact Factor: 4.6 2023 SCImago Journal Rankings: 2.396 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Spinks, JA | en_US |
dc.contributor.author | Dow, R | en_US |
dc.contributor.author | Chiu, LW | en_US |
dc.date.accessioned | 2012-12-19T09:43:54Z | - |
dc.date.available | 2012-12-19T09:43:54Z | - |
dc.date.issued | 1983 | en_US |
dc.identifier.citation | Behavior Research Methods & Instrumentation, 1983, v. 15 n. 6, p. 591-593 | en_US |
dc.identifier.issn | 1554-351X | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/178248 | - |
dc.description.abstract | A suite of programs has been developed to acquire data from a commercially available, highquality skin conductance meter, via a standard IEEE bus, on an Apple II or Apple lie microcomputer. These programs score and analyze stimulus-evoked skin conductance responses in a preset time window, and store the resultant data on disk, if required. Facilities for a manual override of the automatic scoring routine are available. The setup offers a method of scoring data as they are acquired; it uses currently recommended standards for skin conductance analysis and allows a high magnification of responses, without any need for continual monitoring, because of hardware facilities that automatically "back-off" a subject's tonic skin conductance level. © 1983 Psychonomic Society, Inc. | en_US |
dc.language | eng | en_US |
dc.publisher | Psychonomic Society, Inc. The Journal's web site is located at http://www.psychonomic.org/BRMIC/ | en_US |
dc.relation.ispartof | Behavior Research Methods & Instrumentation | en_US |
dc.title | A microcomputer package for real-time skin conductance response analysis | en_US |
dc.type | Article | en_US |
dc.identifier.email | Spinks, JA: spinks@hku.hk | en_US |
dc.identifier.authority | Spinks, JA=rp00063 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.3758/BF03203729 | en_US |
dc.identifier.scopus | eid_2-s2.0-84864889693 | en_US |
dc.identifier.volume | 15 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.spage | 591 | en_US |
dc.identifier.epage | 593 | en_US |
dc.identifier.isi | WOS:A1983SC13900009 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Spinks, JA=6701628658 | en_US |
dc.identifier.scopusauthorid | Dow, R=55334016300 | en_US |
dc.identifier.scopusauthorid | Chiu, LW=55333469300 | en_US |
dc.identifier.issnl | 1554-351X | - |