File Download
There are no files associated with this item.
Supplementary
- Citations:
- Appears in Collections:
Article: The Moberg pickup test: Results of testing with a standard protocol
Title | The Moberg pickup test: Results of testing with a standard protocol |
---|---|
Authors | |
Issue Date | 1999 |
Publisher | Hanley & Belfus, Inc. The Journal's web site is located at http://www.elsevier.com/locate/jht |
Citation | Journal Of Hand Therapy, 1999, v. 12 n. 4, p. 309-312 How to Cite? |
Abstract | The purpose of this study was to propose a standard protocol for administering the Moberg pickup test. One hundred subjects (53 male and 47 female subjects, aged 11 to 77 years) volunteered. A wide variety of occupations were represented. No subjects had a history of upper extremity dysfunction. The materials and the testing procedures were clearly described to the subjects. Both hand dominance and gender difference were found to have significant effects on test performance. Norms were established for dominant/nondominant hands and for male/female subjects. Standard scores were calculated and used for comparison. The inter-rater reliability of the test was also determined. Administered with a standard protocol, the Moberg pickup test is a valuable test of functional sensibility. It is simple and quick to administer, easy to replicate, and inexpensive to acquire. |
Persistent Identifier | http://hdl.handle.net/10722/178216 |
ISSN | 2023 Impact Factor: 2.1 2023 SCImago Journal Rankings: 0.690 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ng, CL | en_US |
dc.contributor.author | Ho, DD | en_US |
dc.contributor.author | Chow, SP | en_US |
dc.date.accessioned | 2012-12-19T09:43:28Z | - |
dc.date.available | 2012-12-19T09:43:28Z | - |
dc.date.issued | 1999 | en_US |
dc.identifier.citation | Journal Of Hand Therapy, 1999, v. 12 n. 4, p. 309-312 | en_US |
dc.identifier.issn | 0894-1130 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/178216 | - |
dc.description.abstract | The purpose of this study was to propose a standard protocol for administering the Moberg pickup test. One hundred subjects (53 male and 47 female subjects, aged 11 to 77 years) volunteered. A wide variety of occupations were represented. No subjects had a history of upper extremity dysfunction. The materials and the testing procedures were clearly described to the subjects. Both hand dominance and gender difference were found to have significant effects on test performance. Norms were established for dominant/nondominant hands and for male/female subjects. Standard scores were calculated and used for comparison. The inter-rater reliability of the test was also determined. Administered with a standard protocol, the Moberg pickup test is a valuable test of functional sensibility. It is simple and quick to administer, easy to replicate, and inexpensive to acquire. | en_US |
dc.language | eng | en_US |
dc.publisher | Hanley & Belfus, Inc. The Journal's web site is located at http://www.elsevier.com/locate/jht | en_US |
dc.relation.ispartof | Journal of Hand Therapy | en_US |
dc.subject.mesh | Activities Of Daily Living | en_US |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Aged, 80 And Over | en_US |
dc.subject.mesh | Child | en_US |
dc.subject.mesh | Clinical Protocols - Standards | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Functional Laterality | en_US |
dc.subject.mesh | Hand Strength - Physiology | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle Aged | en_US |
dc.subject.mesh | Neurologic Examination - Methods - Standards | en_US |
dc.subject.mesh | Observer Variation | en_US |
dc.subject.mesh | Psychomotor Performance - Physiology | en_US |
dc.subject.mesh | Reference Values | en_US |
dc.subject.mesh | Reproducibility Of Results | en_US |
dc.subject.mesh | Sensitivity And Specificity | en_US |
dc.subject.mesh | Sex Characteristics | en_US |
dc.subject.mesh | Time Factors | en_US |
dc.subject.mesh | Touch - Physiology | en_US |
dc.title | The Moberg pickup test: Results of testing with a standard protocol | en_US |
dc.type | Article | en_US |
dc.identifier.email | Chow, SP: spchow@hku.hk | en_US |
dc.identifier.authority | Chow, SP=rp00064 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.pmid | 10622197 | - |
dc.identifier.scopus | eid_2-s2.0-0033372049 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0033372049&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 12 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.spage | 309 | en_US |
dc.identifier.epage | 312 | en_US |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Ng, CL=21646611600 | en_US |
dc.identifier.scopusauthorid | Ho, DD=7402972049 | en_US |
dc.identifier.scopusauthorid | Chow, SP=7201828376 | en_US |
dc.identifier.issnl | 0894-1130 | - |