Article: A safe technique for the insertion of Hickman catheter into the internal jugular vein

TitleA safe technique for the insertion of Hickman catheter into the internal jugular vein
Authors
Issue Date1988
PublisherSage Publications, Inc.. The Journal's web site is located at http://pen.sagepub.com
Citation
Journal Of Parenteral And Enteral Nutrition, 1988, v. 12 n. 2, p. 223-224 How to Cite?
Abstract
A modified technique of inserting a Hickman catheter into the internal jugular vein is described. Instead of using a purse string suture, this technique involves the complete isolation of a short segment of the internal jugular vein and the application of bulldog vascular clamps above and below the site of venotomy. By such modification, the risk of intraoperative bleeding and air embolism is reduced, unilateral advancement of the catheter into the superior vena cava is ensured and the caliber of the vein is not narrowed.
Persistent Identifierhttp://hdl.handle.net/10722/172581
ISSN
2013 Impact Factor: 3.143
2013 SCImago Journal Rankings: 1.141
ISI Accession Number ID

 

Author Affiliations
  1. Queen Mary Hospital Hong Kong
DC FieldValueLanguage
dc.contributor.authorFan, STen_US
dc.date.accessioned2012-10-30T06:23:31Z-
dc.date.available2012-10-30T06:23:31Z-
dc.date.issued1988en_US
dc.identifier.citationJournal Of Parenteral And Enteral Nutrition, 1988, v. 12 n. 2, p. 223-224en_US
dc.identifier.issn0148-6071en_US
dc.identifier.urihttp://hdl.handle.net/10722/172581-
dc.description.abstractA modified technique of inserting a Hickman catheter into the internal jugular vein is described. Instead of using a purse string suture, this technique involves the complete isolation of a short segment of the internal jugular vein and the application of bulldog vascular clamps above and below the site of venotomy. By such modification, the risk of intraoperative bleeding and air embolism is reduced, unilateral advancement of the catheter into the superior vena cava is ensured and the caliber of the vein is not narrowed.en_US
dc.languageengen_US
dc.publisherSage Publications, Inc.. The Journal's web site is located at http://pen.sagepub.comen_US
dc.relation.ispartofJournal of Parenteral and Enteral Nutritionen_US
dc.subject.meshCatheterization - Methodsen_US
dc.subject.meshHumansen_US
dc.subject.meshJugular Veinsen_US
dc.titleA safe technique for the insertion of Hickman catheter into the internal jugular veinen_US
dc.typeArticleen_US
dc.identifier.emailFan, ST: stfan@hku.hken_US
dc.identifier.authorityFan, ST=rp00355en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1177/0148607188012002223-
dc.identifier.pmid3361686en_US
dc.identifier.scopuseid_2-s2.0-0023852234en_US
dc.identifier.volume12en_US
dc.identifier.issue2en_US
dc.identifier.spage223en_US
dc.identifier.epage224en_US
dc.identifier.isiWOS:A1988M600600026-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridFan, ST=7402678224en_US

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats