Article: Republished error management: Paediatric dosing errors before and after electronic prescribing
Title | Republished error management: Paediatric dosing errors before and after electronic prescribing |
---|---|
Authors | |
Issue Date | 2011 |
Publisher | B M J Publishing Group. The Journal's web site is located at http://www.postgradmedj.com |
Citation | Postgraduate Medical Journal, 2011, v. 87 n. 1030, p. 565-568 How to Cite? |
Abstract | Objective To compare the incidence and severity rating of dose prescribing errors before and after the implementation of a commercially available electronic prescribing system at a tertiary care children's hospital. Methods Dose errors were identified using prescription review to detect errors. Severity rating was determined by five judges using a validated, reliable scoring tool. The mean score for each error was used as an index of severity. Results Dose prescribing errors occurred in 88 of the 3939 (2.2%) items prescribed for outpatients and inpatients, and on discharge prescriptions prior to the implementation of electronic prescribing (EP). After EP, there were 57 dose errors in 4784 (1.2%) items prescribed (1% absolute reduction (p<0.001 χ 2 test; 95% CI of difference in proportions -1.6% to -0.5%)). A decrease in the severity rating of dose errors was also seen: dose errors with potentially minor outcomes 35/3939 (0.89%) pre vs 21/4784 (0.44%) post (95% CI of difference in proportions -0.8% to -0.11%, p=0.009 χ 2 test); moderate outcome 46/3939 (1.17%) pre vs 33/4784 (0.69%) post (95% CI of difference in proportions -0.91% to -0.08, p=0.019, χ 2 test); severe outcome: 7/3939 (0.18%) pre vs 3/4784 (0.06%) post (95% CI of difference in proportions -0.31% to +0.04, p=0.11, χ 2 test). Conclusion Electronic prescribing appears to reduce rates of dosing errors in paediatrics, but larger studies are required to assess the effect on the severity of these errors and in different settings. © 2011 The Fellowship of Postgraduate Medicine. |
Persistent Identifier | http://hdl.handle.net/10722/171426 |
ISSN | 2023 Impact Factor: 3.6 2023 SCImago Journal Rankings: 0.876 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jani, YH | en_US |
dc.contributor.author | Barber, N | en_US |
dc.contributor.author | Wong, ICK | en_US |
dc.date.accessioned | 2012-10-30T06:14:06Z | - |
dc.date.available | 2012-10-30T06:14:06Z | - |
dc.date.issued | 2011 | en_US |
dc.identifier.citation | Postgraduate Medical Journal, 2011, v. 87 n. 1030, p. 565-568 | en_US |
dc.identifier.issn | 0032-5473 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/171426 | - |
dc.description.abstract | Objective To compare the incidence and severity rating of dose prescribing errors before and after the implementation of a commercially available electronic prescribing system at a tertiary care children's hospital. Methods Dose errors were identified using prescription review to detect errors. Severity rating was determined by five judges using a validated, reliable scoring tool. The mean score for each error was used as an index of severity. Results Dose prescribing errors occurred in 88 of the 3939 (2.2%) items prescribed for outpatients and inpatients, and on discharge prescriptions prior to the implementation of electronic prescribing (EP). After EP, there were 57 dose errors in 4784 (1.2%) items prescribed (1% absolute reduction (p<0.001 χ 2 test; 95% CI of difference in proportions -1.6% to -0.5%)). A decrease in the severity rating of dose errors was also seen: dose errors with potentially minor outcomes 35/3939 (0.89%) pre vs 21/4784 (0.44%) post (95% CI of difference in proportions -0.8% to -0.11%, p=0.009 χ 2 test); moderate outcome 46/3939 (1.17%) pre vs 33/4784 (0.69%) post (95% CI of difference in proportions -0.91% to -0.08, p=0.019, χ 2 test); severe outcome: 7/3939 (0.18%) pre vs 3/4784 (0.06%) post (95% CI of difference in proportions -0.31% to +0.04, p=0.11, χ 2 test). Conclusion Electronic prescribing appears to reduce rates of dosing errors in paediatrics, but larger studies are required to assess the effect on the severity of these errors and in different settings. © 2011 The Fellowship of Postgraduate Medicine. | en_US |
dc.language | eng | en_US |
dc.publisher | B M J Publishing Group. The Journal's web site is located at http://www.postgradmedj.com | en_US |
dc.relation.ispartof | Postgraduate Medical Journal | en_US |
dc.title | Republished error management: Paediatric dosing errors before and after electronic prescribing | en_US |
dc.type | Article | en_US |
dc.identifier.email | Wong, ICK:wongick@hku.hk | en_US |
dc.identifier.authority | Wong, ICK=rp01480 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1136/pgmj.2009.033068rep | en_US |
dc.identifier.pmid | 21788235 | - |
dc.identifier.scopus | eid_2-s2.0-79960828100 | en_US |
dc.identifier.hkuros | 207208 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-79960828100&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 87 | en_US |
dc.identifier.issue | 1030 | en_US |
dc.identifier.spage | 565 | en_US |
dc.identifier.epage | 568 | en_US |
dc.identifier.isi | WOS:000293076800011 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Jani, YH=6603352762 | en_US |
dc.identifier.scopusauthorid | Barber, N=7005001200 | en_US |
dc.identifier.scopusauthorid | Wong, ICK=7102513915 | en_US |
dc.identifier.issnl | 0032-5473 | - |