File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Voltage dependent reactive power limits for voltage stability studies

TitleVoltage dependent reactive power limits for voltage stability studies
Authors
Issue Date1995
PublisherI E E E. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=59
Citation
Ieee Transactions On Power Systems, 1995, v. 10 n. 1, p. 220-228 How to Cite?
AbstractThis paper presents and studies a static model for synchronous generators with voltage dependent reactive power limits due to maximum stator current, maximum and minimum rotor (field) current as well as maximum rotor angle (underexcitation) limiters. The proposed generator model for static voltage stability studies can be included in an ordinary power flow program, and results from studies on a test system with twenty generators are presented. The influence of voltage dependent reactive power limits is compared with fixed (conventional) limits, by use of the minimum singular value of the power flow Jacobian matrix and related submatrices as indicators of the static voltage stability limit.
Persistent Identifierhttp://hdl.handle.net/10722/169642
ISSN
2021 Impact Factor: 7.326
2020 SCImago Journal Rankings: 3.312
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLof, PAen_US
dc.contributor.authorAndersson, Gen_US
dc.contributor.authorHill, DJen_US
dc.date.accessioned2012-10-25T04:53:59Z-
dc.date.available2012-10-25T04:53:59Z-
dc.date.issued1995en_US
dc.identifier.citationIeee Transactions On Power Systems, 1995, v. 10 n. 1, p. 220-228en_US
dc.identifier.issn0885-8950en_US
dc.identifier.urihttp://hdl.handle.net/10722/169642-
dc.description.abstractThis paper presents and studies a static model for synchronous generators with voltage dependent reactive power limits due to maximum stator current, maximum and minimum rotor (field) current as well as maximum rotor angle (underexcitation) limiters. The proposed generator model for static voltage stability studies can be included in an ordinary power flow program, and results from studies on a test system with twenty generators are presented. The influence of voltage dependent reactive power limits is compared with fixed (conventional) limits, by use of the minimum singular value of the power flow Jacobian matrix and related submatrices as indicators of the static voltage stability limit.en_US
dc.languageengen_US
dc.publisherI E E E. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=59en_US
dc.relation.ispartofIEEE Transactions on Power Systemsen_US
dc.titleVoltage dependent reactive power limits for voltage stability studiesen_US
dc.typeArticleen_US
dc.identifier.emailHill, DJ:en_US
dc.identifier.authorityHill, DJ=rp01669en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/59.373945en_US
dc.identifier.scopuseid_2-s2.0-0029252793en_US
dc.identifier.volume10en_US
dc.identifier.issue1en_US
dc.identifier.spage220en_US
dc.identifier.epage228en_US
dc.identifier.isiWOS:A1995QK23600026-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridLof, PA=6506932700en_US
dc.identifier.scopusauthoridAndersson, G=35552392600en_US
dc.identifier.scopusauthoridHill, DJ=35398599500en_US
dc.identifier.issnl0885-8950-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats