TitleSwitched-capacitor converters with multiphase interleaving control
Authors
Issue Date2011
Citation
Ieee Energy Conversion Congress And Exposition: Energy Conversion Innovation For A Clean Energy Future, Ecce 2011, Proceedings, 2011, p. 1156-1161 How to Cite?
AbstractThis paper proposes a configuration of switched-capacitor converters with multiphase interleaving control that can perform conventional switched-capacitor voltage conversions with little electromagnetic interference over a wide range of operating condition. This is achieved by having multiple units of switched-capacitor converter connected in parallel and a unit selection control scheme which works along the interleaving control to vary the number of converters in operation. By having the capacitors of inactive units connected to the output and the converters operating with output interleaving operation, the output capacitor that is typically required in switched-capacitor converters for maintaining a small voltage ripple is made redundant in this configuration. © 2011 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/158741
References

 

DC FieldValueLanguage
dc.contributor.authorKiratipongvoot, Sen_US
dc.contributor.authorTan, SCen_US
dc.contributor.authorIoinovici, Aen_US
dc.date.accessioned2012-08-08T09:01:06Z-
dc.date.available2012-08-08T09:01:06Z-
dc.date.issued2011en_US
dc.identifier.citationIeee Energy Conversion Congress And Exposition: Energy Conversion Innovation For A Clean Energy Future, Ecce 2011, Proceedings, 2011, p. 1156-1161en_US
dc.identifier.urihttp://hdl.handle.net/10722/158741-
dc.description.abstractThis paper proposes a configuration of switched-capacitor converters with multiphase interleaving control that can perform conventional switched-capacitor voltage conversions with little electromagnetic interference over a wide range of operating condition. This is achieved by having multiple units of switched-capacitor converter connected in parallel and a unit selection control scheme which works along the interleaving control to vary the number of converters in operation. By having the capacitors of inactive units connected to the output and the converters operating with output interleaving operation, the output capacitor that is typically required in switched-capacitor converters for maintaining a small voltage ripple is made redundant in this configuration. © 2011 IEEE.en_US
dc.languageengen_US
dc.relation.ispartofIEEE Energy Conversion Congress and Exposition: Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedingsen_US
dc.titleSwitched-capacitor converters with multiphase interleaving controlen_US
dc.typeConference_Paperen_US
dc.identifier.emailTan, SC:sctan@hku.hken_US
dc.identifier.authorityTan, SC=rp01606en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/ECCE.2011.6063906en_US
dc.identifier.scopuseid_2-s2.0-81855206222en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-81855206222&selection=ref&src=s&origin=recordpageen_US
dc.identifier.spage1156en_US
dc.identifier.epage1161en_US
dc.identifier.scopusauthoridKiratipongvoot, S=35098739400en_US
dc.identifier.scopusauthoridTan, SC=26642772000en_US
dc.identifier.scopusauthoridIoinovici, A=7003591597en_US

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats