File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: 92% pump depletion in a CW one-pump fiber OPA
Title | 92% pump depletion in a CW one-pump fiber OPA |
---|---|
Authors | |
Issue Date | 2001 |
Citation | Conference On Lasers And Electro-Optics Europe - Technical Digest, 2001, p. 569-570 How to Cite? |
Abstract | The 92% pump depletion in continuous wave (CW) fibers with a 200mW pump at 1560nm in an 11km long dispersion shifted fiber (DSF) was demonstrated. A high signal power was launched into the fiber to observe a high level of pump depletion. The pump power at the input of the DSF was maintained at 23dBm to provide significant optical parametric amplifiers (OPA) gain control for the signal. It was found that when the input signal power was about 9dBm the maximum pump depletion was 11dB. |
Persistent Identifier | http://hdl.handle.net/10722/158309 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wong, KY | en_US |
dc.contributor.author | Marhic, ME | en_US |
dc.contributor.author | Ho, MC | en_US |
dc.contributor.author | Kazovsky, LG | en_US |
dc.date.accessioned | 2012-08-08T08:59:00Z | - |
dc.date.available | 2012-08-08T08:59:00Z | - |
dc.date.issued | 2001 | en_US |
dc.identifier.citation | Conference On Lasers And Electro-Optics Europe - Technical Digest, 2001, p. 569-570 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/158309 | - |
dc.description.abstract | The 92% pump depletion in continuous wave (CW) fibers with a 200mW pump at 1560nm in an 11km long dispersion shifted fiber (DSF) was demonstrated. A high signal power was launched into the fiber to observe a high level of pump depletion. The pump power at the input of the DSF was maintained at 23dBm to provide significant optical parametric amplifiers (OPA) gain control for the signal. It was found that when the input signal power was about 9dBm the maximum pump depletion was 11dB. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Conference on Lasers and Electro-Optics Europe - Technical Digest | en_US |
dc.title | 92% pump depletion in a CW one-pump fiber OPA | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Wong, KY:kywong@eee.hku.hk | en_US |
dc.identifier.authority | Wong, KY=rp00189 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-0034811499 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0034811499&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.spage | 569 | en_US |
dc.identifier.epage | 570 | en_US |
dc.identifier.scopusauthorid | Wong, KY=36456599700 | en_US |
dc.identifier.scopusauthorid | Marhic, ME=7006249671 | en_US |
dc.identifier.scopusauthorid | Ho, MC=7403080983 | en_US |
dc.identifier.scopusauthorid | Kazovsky, LG=7102269962 | en_US |