Conference Paper: Power quality investigation of cluster of phase controlled rectifiers of airport grounding lighting system

TitlePower quality investigation of cluster of phase controlled rectifiers of airport grounding lighting system
Authors
Issue Date1999
Citation
Iecon Proceedings (Industrial Electronics Conference), 1999, v. 1, p. 247-252 How to Cite?
AbstractSingle phase thyristor rectifiers are widely used in modern airport as dc power supply for such loads as air-conditioners, communication, computers and airport grounding lighting system(AGL). The disadvantages of this kind of rectifiers are the waveform distortion and the unbalance of loading, both of which have become a concern at many airports. In this paper, the harmonics produced by clusters of phase controlled rectifiers of airport grounding lighting system are studied based on experimental measurement. It is shown these rectifiers are the dominant harmonics source of the airport electrical power system. Harmonic pollution is found to be closely related to the load level of airport grounding lighting system. Voltage waveform distortion at point of common coupling (PCC) is primarily a result of harmonic current generated by the power electronics controlled loads. It is also found total voltage harmonics distortion does not necessarily increase with the increase of current distortion at PCC. The harmonics and unbalance for combined loads are also investigated in this paper. Severe unbalance is observed which is disadvantageous for the power transformer and the auxiliary generator.
Persistent Identifierhttp://hdl.handle.net/10722/158264

 

DC FieldValueLanguage
dc.contributor.authorYe, Zhongmingen_US
dc.contributor.authorLo, Edwarden_US
dc.contributor.authorPong, MHen_US
dc.contributor.authorTang, Pingen_US
dc.date.accessioned2012-08-08T08:58:48Z-
dc.date.available2012-08-08T08:58:48Z-
dc.date.issued1999en_US
dc.identifier.citationIecon Proceedings (Industrial Electronics Conference), 1999, v. 1, p. 247-252en_US
dc.identifier.urihttp://hdl.handle.net/10722/158264-
dc.description.abstractSingle phase thyristor rectifiers are widely used in modern airport as dc power supply for such loads as air-conditioners, communication, computers and airport grounding lighting system(AGL). The disadvantages of this kind of rectifiers are the waveform distortion and the unbalance of loading, both of which have become a concern at many airports. In this paper, the harmonics produced by clusters of phase controlled rectifiers of airport grounding lighting system are studied based on experimental measurement. It is shown these rectifiers are the dominant harmonics source of the airport electrical power system. Harmonic pollution is found to be closely related to the load level of airport grounding lighting system. Voltage waveform distortion at point of common coupling (PCC) is primarily a result of harmonic current generated by the power electronics controlled loads. It is also found total voltage harmonics distortion does not necessarily increase with the increase of current distortion at PCC. The harmonics and unbalance for combined loads are also investigated in this paper. Severe unbalance is observed which is disadvantageous for the power transformer and the auxiliary generator.en_US
dc.languageengen_US
dc.relation.ispartofIECON Proceedings (Industrial Electronics Conference)en_US
dc.titlePower quality investigation of cluster of phase controlled rectifiers of airport grounding lighting systemen_US
dc.typeConference_Paperen_US
dc.identifier.emailPong, MH:mhp@eee.hku.hken_US
dc.identifier.authorityPong, MH=rp00163en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.scopuseid_2-s2.0-0033282997en_US
dc.identifier.volume1en_US
dc.identifier.spage247en_US
dc.identifier.epage252en_US
dc.identifier.scopusauthoridYe, Zhongming=7401956889en_US
dc.identifier.scopusauthoridLo, Edward=7101706013en_US
dc.identifier.scopusauthoridPong, MH=7003449364en_US
dc.identifier.scopusauthoridTang, Ping=36719642400en_US

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats