File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Diagnostic parameters for monitoring peri-implant conditions

TitleDiagnostic parameters for monitoring peri-implant conditions
Authors
KeywordsClinical parameters
Dental implants
Dental radiography
Diagnosis
Long-term evaluation
Peri-implant disease
Issue Date2004
PublisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.com/journals/omi/gp.php?journal_name=OMI&name_abbr=IJOMI
Citation
International Journal Of Oral And Maxillofacial Implants, 2004, v. 19 SUPPL., p. 116-127 How to Cite?
AbstractPurpose: To review the literature on clinical, radiographic, and biochemical parameters used for monitoring peri-implant conditions. Materials and Methods: A MEDLINE search was conducted that included articles published in English until the end of August 2003, Results from human and experimental animal studies are presented. Results: The parameters that may be used to assess the presence of peri-implant health and the severity of peri-implant disease include plaque assessment, mucosal conditions, peri-implant probing depth, width of the peri-implant keratinized mucosa, periimplant sulcus fluid analysis, suppuration, implant mobility and discomfort, resonance frequency analysis, and radiographic evaluation. Discussion: Based on the analysis of the available evidence, it appears reasonable to use a number of clinical and radiographic parameters to discriminate between peri-implant health and disease. Conclusions: Systematic and continuous monitoring of peri-implant tissues during maintenance care is recommended for the early diagnosis of peri-implant disease.
Persistent Identifierhttp://hdl.handle.net/10722/157949
ISSN
2021 Impact Factor: 2.912
2020 SCImago Journal Rankings: 1.109
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorSalvi, GEen_US
dc.contributor.authorLang, NPen_US
dc.date.accessioned2012-08-08T08:57:07Z-
dc.date.available2012-08-08T08:57:07Z-
dc.date.issued2004en_US
dc.identifier.citationInternational Journal Of Oral And Maxillofacial Implants, 2004, v. 19 SUPPL., p. 116-127en_US
dc.identifier.issn0882-2786en_US
dc.identifier.urihttp://hdl.handle.net/10722/157949-
dc.description.abstractPurpose: To review the literature on clinical, radiographic, and biochemical parameters used for monitoring peri-implant conditions. Materials and Methods: A MEDLINE search was conducted that included articles published in English until the end of August 2003, Results from human and experimental animal studies are presented. Results: The parameters that may be used to assess the presence of peri-implant health and the severity of peri-implant disease include plaque assessment, mucosal conditions, peri-implant probing depth, width of the peri-implant keratinized mucosa, periimplant sulcus fluid analysis, suppuration, implant mobility and discomfort, resonance frequency analysis, and radiographic evaluation. Discussion: Based on the analysis of the available evidence, it appears reasonable to use a number of clinical and radiographic parameters to discriminate between peri-implant health and disease. Conclusions: Systematic and continuous monitoring of peri-implant tissues during maintenance care is recommended for the early diagnosis of peri-implant disease.en_US
dc.languageengen_US
dc.publisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.com/journals/omi/gp.php?journal_name=OMI&name_abbr=IJOMIen_US
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implantsen_US
dc.subjectClinical parameters-
dc.subjectDental implants-
dc.subjectDental radiography-
dc.subjectDiagnosis-
dc.subjectLong-term evaluation-
dc.subjectPeri-implant disease-
dc.subject.meshAlveolar Bone Loss - Etiology - Radiographyen_US
dc.subject.meshAnimalsen_US
dc.subject.meshDental Implantation, Endosseous - Adverse Effectsen_US
dc.subject.meshDental Implants - Adverse Effectsen_US
dc.subject.meshDental Plaque Indexen_US
dc.subject.meshDental Prosthesis Retentionen_US
dc.subject.meshDental Restoration Failureen_US
dc.subject.meshHumansen_US
dc.subject.meshMouth Mucosa - Pathologyen_US
dc.subject.meshOsseointegrationen_US
dc.subject.meshPeriodontal Diseases - Diagnosis - Etiologyen_US
dc.subject.meshPeriodontal Indexen_US
dc.subject.meshVibrationen_US
dc.titleDiagnostic parameters for monitoring peri-implant conditionsen_US
dc.typeConference_Paperen_US
dc.identifier.emailLang, NP:nplang@hkucc.hku.hken_US
dc.identifier.authorityLang, NP=rp00031en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.pmid15635952-
dc.identifier.scopuseid_2-s2.0-12244296400en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-12244296400&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume19en_US
dc.identifier.issueSUPPL.en_US
dc.identifier.spage116en_US
dc.identifier.epage127en_US
dc.identifier.isiWOS:000226100500012-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridSalvi, GE=35600695300en_US
dc.identifier.scopusauthoridLang, NP=7201577367en_US
dc.identifier.issnl0882-2786-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats