Article: Mathematical modelling of proton-conducting solid oxide fuel cells and comparison with oxygen-ion-conducting counterpart
Title | Mathematical modelling of proton-conducting solid oxide fuel cells and comparison with oxygen-ion-conducting counterpart |
---|---|
Authors | |
Keywords | Mass transport Overpotential losses Porous media Proton-conducting electrolyte SOFC |
Issue Date | 2007 |
Citation | Fuel Cells, 2007, v. 7 n. 4, p. 269-278 How to Cite? |
Abstract | Proton-conducting solid oxide fuel cells (H-SOFC), using a proton-conducting electrolyte, potentially have higher maximum energy efficiency than conventional oxygen-ion-conducting solid oxide fuel cells (O-SOPC). It is important to theoretically study the current-voltage (J-V) characteristics in detail in order to facilitate advanced development of H-SOFC. In this investigation, a parametric modelling analysis was conducted. An electrochemical H-SOFC model was developed and it was validated as the simulation results agreed well with experimental data published in the literature. Subsequently, the analytical comparison between H-SOFC and O-SOFC was made to evaluate how the use of 1 different electrolytes could affect the SOFC performance. In addition to different ohmic overpotentials at the electrolyte, the concentration overpotentials of an H-SOFC were prominently different from those of an O-SOFC. H-SOFC had very low anode concentration overpotential but suffered seriously from high cathode concentration overpotential. The differences found indicated that H-SOFC possessed fuel cell characteristics different from conventional O-SOFC. Particular H-SOFC electrochemical modelling and parametric microstructural analysis are essential for the enhancement of H-SOFC performance. Further analysis of this investigation showed that the H-SOFC performance could be enhanced by increasing the gas transport in the cathode with high porosity, large pore size and low tortuosity. © 2007 WILEY-VCH Verlag GmbH & Co. KGaA. |
Persistent Identifier | http://hdl.handle.net/10722/156911 |
ISSN | 2023 Impact Factor: 2.6 2023 SCImago Journal Rankings: 0.572 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ni, M | en_HK |
dc.contributor.author | Leung, MKH | en_HK |
dc.contributor.author | Leung, DYC | en_HK |
dc.date.accessioned | 2012-08-08T08:44:31Z | - |
dc.date.available | 2012-08-08T08:44:31Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Fuel Cells, 2007, v. 7 n. 4, p. 269-278 | en_HK |
dc.identifier.issn | 1615-6846 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/156911 | - |
dc.description.abstract | Proton-conducting solid oxide fuel cells (H-SOFC), using a proton-conducting electrolyte, potentially have higher maximum energy efficiency than conventional oxygen-ion-conducting solid oxide fuel cells (O-SOPC). It is important to theoretically study the current-voltage (J-V) characteristics in detail in order to facilitate advanced development of H-SOFC. In this investigation, a parametric modelling analysis was conducted. An electrochemical H-SOFC model was developed and it was validated as the simulation results agreed well with experimental data published in the literature. Subsequently, the analytical comparison between H-SOFC and O-SOFC was made to evaluate how the use of 1 different electrolytes could affect the SOFC performance. In addition to different ohmic overpotentials at the electrolyte, the concentration overpotentials of an H-SOFC were prominently different from those of an O-SOFC. H-SOFC had very low anode concentration overpotential but suffered seriously from high cathode concentration overpotential. The differences found indicated that H-SOFC possessed fuel cell characteristics different from conventional O-SOFC. Particular H-SOFC electrochemical modelling and parametric microstructural analysis are essential for the enhancement of H-SOFC performance. Further analysis of this investigation showed that the H-SOFC performance could be enhanced by increasing the gas transport in the cathode with high porosity, large pore size and low tortuosity. © 2007 WILEY-VCH Verlag GmbH & Co. KGaA. | en_HK |
dc.language | eng | en_US |
dc.relation.ispartof | Fuel Cells | en_HK |
dc.subject | Mass transport | en_HK |
dc.subject | Overpotential losses | en_HK |
dc.subject | Porous media | en_HK |
dc.subject | Proton-conducting electrolyte | en_HK |
dc.subject | SOFC | en_HK |
dc.title | Mathematical modelling of proton-conducting solid oxide fuel cells and comparison with oxygen-ion-conducting counterpart | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Leung, MKH: | en_HK |
dc.identifier.email | Leung, DYC: ycleung@hku.hk | en_HK |
dc.identifier.authority | Leung, MKH=rp00148 | en_HK |
dc.identifier.authority | Leung, DYC=rp00149 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1002/fuce.200600049 | en_HK |
dc.identifier.scopus | eid_2-s2.0-34548013064 | en_HK |
dc.identifier.hkuros | 142199 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-34548013064&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 7 | en_HK |
dc.identifier.issue | 4 | en_HK |
dc.identifier.spage | 269 | en_HK |
dc.identifier.epage | 278 | en_HK |
dc.identifier.isi | WOS:000248849000002 | - |
dc.publisher.place | Germany | en_HK |
dc.identifier.scopusauthorid | Ni, M=9268339800 | en_HK |
dc.identifier.scopusauthorid | Leung, MKH=8862966600 | en_HK |
dc.identifier.scopusauthorid | Leung, DYC=7203002484 | en_HK |
dc.identifier.issnl | 1615-6846 | - |