File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/23.289388
- Scopus: eid_2-s2.0-0026142581
- WOS: WOS:A1991FK17300121
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Fast calibration method of 4 × 4 detector module for F-SPET
Title | Fast calibration method of 4 × 4 detector module for F-SPET |
---|---|
Authors | |
Issue Date | 1991 |
Citation | Ieee Transactions On Nuclear Science, 1991, v. 38 n. 2 pt I, p. 770-775 How to Cite? |
Abstract | A novel system and method of light coupling analysis and calibration for the 4 × 4 detector module of the Columbia University spherical PET (positron emission tomography unit) is discussed, and its performance is evaluated. The new features of the system include a simulated-scintillation-signal generator which effectively replaces the scintillation signal from the photomultiplier tube and a multiple-channel analog-to-digital converter for simultaneous recording of all signals of interest. A fast and reliable calibration method for the 4 × 4 detector module and front-end circuit has been developed using this calibration system. Since the proposed calibration method is based on the light coupling analysis, it is possible to use an uncollimated source for the position calibration, thereby eliminating the time-consuming procedure usually used in calibration of the position-encoded detector assembly. |
Persistent Identifier | http://hdl.handle.net/10722/154940 |
ISSN | 2023 Impact Factor: 1.9 2023 SCImago Journal Rankings: 0.537 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, YS | en_US |
dc.contributor.author | Lee, KD | en_US |
dc.contributor.author | Wu, EX | en_US |
dc.contributor.author | Hilal, SK | en_US |
dc.contributor.author | Cho, ZH | en_US |
dc.date.accessioned | 2012-08-08T08:31:13Z | - |
dc.date.available | 2012-08-08T08:31:13Z | - |
dc.date.issued | 1991 | en_US |
dc.identifier.citation | Ieee Transactions On Nuclear Science, 1991, v. 38 n. 2 pt I, p. 770-775 | en_US |
dc.identifier.issn | 0018-9499 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/154940 | - |
dc.description.abstract | A novel system and method of light coupling analysis and calibration for the 4 × 4 detector module of the Columbia University spherical PET (positron emission tomography unit) is discussed, and its performance is evaluated. The new features of the system include a simulated-scintillation-signal generator which effectively replaces the scintillation signal from the photomultiplier tube and a multiple-channel analog-to-digital converter for simultaneous recording of all signals of interest. A fast and reliable calibration method for the 4 × 4 detector module and front-end circuit has been developed using this calibration system. Since the proposed calibration method is based on the light coupling analysis, it is possible to use an uncollimated source for the position calibration, thereby eliminating the time-consuming procedure usually used in calibration of the position-encoded detector assembly. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | IEEE Transactions on Nuclear Science | en_US |
dc.title | Fast calibration method of 4 × 4 detector module for F-SPET | en_US |
dc.type | Article | en_US |
dc.identifier.email | Wu, EX:ewu1@hkucc.hku.hk | en_US |
dc.identifier.authority | Wu, EX=rp00193 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1109/23.289388 | en_US |
dc.identifier.scopus | eid_2-s2.0-0026142581 | en_US |
dc.identifier.volume | 38 | en_US |
dc.identifier.issue | 2 pt I | en_US |
dc.identifier.spage | 770 | en_US |
dc.identifier.epage | 775 | en_US |
dc.identifier.isi | WOS:A1991FK17300121 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Kim, YS=7410195659 | en_US |
dc.identifier.scopusauthorid | Lee, KD=7501516856 | en_US |
dc.identifier.scopusauthorid | Wu, EX=7202128034 | en_US |
dc.identifier.scopusauthorid | Hilal, SK=7004804427 | en_US |
dc.identifier.scopusauthorid | Cho, ZH=7006289037 | en_US |
dc.identifier.issnl | 0018-9499 | - |