File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1111/j.1600-0501.2007.01336.x
- Scopus: eid_2-s2.0-34547217298
- PMID: 17355357
- WOS: WOS:000247240800002
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation
Title | Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation |
---|---|
Authors | |
Keywords | Implant stability Jawbone Micro-CT Osstell® RFA Titanium implants Wound healing |
Issue Date | 2007 |
Publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR |
Citation | Clinical Oral Implants Research, 2007, v. 18 n. 3, p. 275-280 How to Cite? |
Abstract | Objectives: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann® dental implants with an SLA surface. Material and methods: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). Results: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. Conclusion: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact. © 2007 Blackwell Munksgaard. |
Persistent Identifier | http://hdl.handle.net/10722/154473 |
ISSN | 2023 Impact Factor: 4.8 2023 SCImago Journal Rankings: 1.865 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Huwiler, MA | en_US |
dc.contributor.author | Pjetursson, BE | en_US |
dc.contributor.author | Bosshardt, DD | en_US |
dc.contributor.author | Salvi, GE | en_US |
dc.contributor.author | Lang, NP | en_US |
dc.date.accessioned | 2012-08-08T08:25:31Z | - |
dc.date.available | 2012-08-08T08:25:31Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.citation | Clinical Oral Implants Research, 2007, v. 18 n. 3, p. 275-280 | en_US |
dc.identifier.issn | 0905-7161 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/154473 | - |
dc.description.abstract | Objectives: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann® dental implants with an SLA surface. Material and methods: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). Results: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. Conclusion: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact. © 2007 Blackwell Munksgaard. | en_US |
dc.language | eng | en_US |
dc.publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR | en_US |
dc.relation.ispartof | Clinical Oral Implants Research | en_US |
dc.subject | Implant stability | - |
dc.subject | Jawbone | - |
dc.subject | Micro-CT | - |
dc.subject | Osstell® | - |
dc.subject | RFA | - |
dc.subject | Titanium implants | - |
dc.subject | Wound healing | - |
dc.subject.mesh | Alveolar Process - Pathology | en_US |
dc.subject.mesh | Analysis Of Variance | en_US |
dc.subject.mesh | Bone Density | en_US |
dc.subject.mesh | Dental Implantation, Endosseous - Methods | en_US |
dc.subject.mesh | Dental Implants | en_US |
dc.subject.mesh | Electron Probe Microanalysis - Methods | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Linear Models | en_US |
dc.subject.mesh | Periodontal Index | en_US |
dc.subject.mesh | Wound Healing | en_US |
dc.title | Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation | en_US |
dc.type | Article | en_US |
dc.identifier.email | Lang, NP:nplang@hkucc.hku.hk | en_US |
dc.identifier.authority | Lang, NP=rp00031 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1111/j.1600-0501.2007.01336.x | en_US |
dc.identifier.pmid | 17355357 | - |
dc.identifier.scopus | eid_2-s2.0-34547217298 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-34547217298&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 18 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.spage | 275 | en_US |
dc.identifier.epage | 280 | en_US |
dc.identifier.isi | WOS:000247240800002 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Huwiler, MA=6505925627 | en_US |
dc.identifier.scopusauthorid | Pjetursson, BE=6506841442 | en_US |
dc.identifier.scopusauthorid | Bosshardt, DD=6603806230 | en_US |
dc.identifier.scopusauthorid | Salvi, GE=35600695300 | en_US |
dc.identifier.scopusauthorid | Lang, NP=7201577367 | en_US |
dc.identifier.citeulike | 1313244 | - |
dc.identifier.issnl | 0905-7161 | - |