File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Long-span, fixed-movable, resin-bonded fixed partial dentures: A retrospective, preliminary clinical investigation

TitleLong-span, fixed-movable, resin-bonded fixed partial dentures: A retrospective, preliminary clinical investigation
Authors
Issue Date2005
PublisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.com
Citation
International Journal Of Prosthodontics, 2005, v. 18 n. 5, p. 371-376 How to Cite?
AbstractPurpose: Long-span, resin-bonded fixed partial dentures (FPDs) have been associated with higher debonding rates than short-span prostheses. The use of modified nonrigid connectors that allow movement between the abutments in long-span resin-bonded prostheses may reduce harmful interabutment forces that stress the metal framework and resin-bonded interface. This preliminary investigation aimed to evaluate the longevity of long-span resin-bonded FPDs of 4 or more units with a modified nonrigid connector and increased extension of the retainer framework around the major abutment. Materials and Methods: Thirty-eight patients attended a clinical examination; each had been provided with 1 or more resin-bonded FPD of 4 or more units (43 prostheses). For each patient, the following data were recorded: gender, age, cementation date, and endodontic treatment, if performed. Data regarding the occurrence of any debondings and patient expectations were also recorded. Results: The mean service life for the 43 prostheses was 46.9 months (SD 22.0), with a range of 12 days to 87 months. Three prostheses had debonded, resulting in a clinical retention rate of 92.2%. Conclusion: Long-span resin-bonded FPDs incorporating nonrigid connectors that allow independent movement between the major and minor retainer, combined with increased framework extension on the major abutment, appear successful in the short term. Further research is required to determine their long-term efficacy.
Persistent Identifierhttp://hdl.handle.net/10722/154366
ISSN
2023 Impact Factor: 2.1
2023 SCImago Journal Rankings: 0.746
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorBotelho, MGen_US
dc.contributor.authorDyson, JEen_US
dc.date.accessioned2012-08-08T08:24:54Z-
dc.date.available2012-08-08T08:24:54Z-
dc.date.issued2005en_US
dc.identifier.citationInternational Journal Of Prosthodontics, 2005, v. 18 n. 5, p. 371-376en_US
dc.identifier.issn0893-2174en_US
dc.identifier.urihttp://hdl.handle.net/10722/154366-
dc.description.abstractPurpose: Long-span, resin-bonded fixed partial dentures (FPDs) have been associated with higher debonding rates than short-span prostheses. The use of modified nonrigid connectors that allow movement between the abutments in long-span resin-bonded prostheses may reduce harmful interabutment forces that stress the metal framework and resin-bonded interface. This preliminary investigation aimed to evaluate the longevity of long-span resin-bonded FPDs of 4 or more units with a modified nonrigid connector and increased extension of the retainer framework around the major abutment. Materials and Methods: Thirty-eight patients attended a clinical examination; each had been provided with 1 or more resin-bonded FPD of 4 or more units (43 prostheses). For each patient, the following data were recorded: gender, age, cementation date, and endodontic treatment, if performed. Data regarding the occurrence of any debondings and patient expectations were also recorded. Results: The mean service life for the 43 prostheses was 46.9 months (SD 22.0), with a range of 12 days to 87 months. Three prostheses had debonded, resulting in a clinical retention rate of 92.2%. Conclusion: Long-span resin-bonded FPDs incorporating nonrigid connectors that allow independent movement between the major and minor retainer, combined with increased framework extension on the major abutment, appear successful in the short term. Further research is required to determine their long-term efficacy.en_US
dc.languageengen_US
dc.publisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.comen_US
dc.relation.ispartofInternational Journal of Prosthodonticsen_US
dc.subject.meshAdulten_US
dc.subject.meshAgeden_US
dc.subject.meshAged, 80 And Overen_US
dc.subject.meshDental Abutmentsen_US
dc.subject.meshDental Restoration Failureen_US
dc.subject.meshDental Stress Analysisen_US
dc.subject.meshDenture Designen_US
dc.subject.meshDenture Retention - Instrumentationen_US
dc.subject.meshDenture, Partial, Fixed, Resin-Bondeden_US
dc.subject.meshFemaleen_US
dc.subject.meshHumansen_US
dc.subject.meshMaleen_US
dc.subject.meshMiddle Ageden_US
dc.subject.meshRetrospective Studiesen_US
dc.titleLong-span, fixed-movable, resin-bonded fixed partial dentures: A retrospective, preliminary clinical investigationen_US
dc.typeArticleen_US
dc.identifier.emailBotelho, MG:botelho@hkucc.hku.hken_US
dc.identifier.emailDyson, JE:jdyson@hkucc.hku.hken_US
dc.identifier.authorityBotelho, MG=rp00033en_US
dc.identifier.authorityDyson, JE=rp00003en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.pmid16220800-
dc.identifier.scopuseid_2-s2.0-26444616534en_US
dc.identifier.hkuros110684-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-26444616534&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume18en_US
dc.identifier.issue5en_US
dc.identifier.spage371en_US
dc.identifier.epage376en_US
dc.identifier.isiWOS:000232091200003-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridBotelho, MG=7005751169en_US
dc.identifier.scopusauthoridDyson, JE=23089868600en_US
dc.identifier.issnl0893-2174-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats