File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Design principles for cantilevered resin-bonded fixed partial dentures

TitleDesign principles for cantilevered resin-bonded fixed partial dentures
Authors
KeywordsAbutment
Cantilevered
Fixed partial dentures
Fixed-fixed design
Resin-bonded
Issue Date2000
PublisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.com
Citation
Quintessence International, 2000, v. 31 n. 9, p. 613-619 How to Cite?
AbstractRecent clinical studies show 2-unit cantilevered resin-bonded fixed partial dentures to be as retentive or more retentive than their fixed-fixed counterparts. The fact that the 2-unit prosthesis is successful adds value to the clinical use of resin-bonded fixed partial dentures because the single-abutment prosthesis is even simpler and more cost effective than fixed-fixed designs. However, there is no evidence-based information relating to design principles for abutment preparation and framework design for the single-abutment, single-retainer prosthesis. The aim of this report is to suggest principles of design for the 2-unit cantilevered fixed partial denture, based on information gained from studies on fixed-fixed designs.
Persistent Identifierhttp://hdl.handle.net/10722/154117
ISSN
2021 Impact Factor: 2.175
2020 SCImago Journal Rankings: 0.646
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorBotelho, Men_US
dc.date.accessioned2012-08-08T08:23:20Z-
dc.date.available2012-08-08T08:23:20Z-
dc.date.issued2000en_US
dc.identifier.citationQuintessence International, 2000, v. 31 n. 9, p. 613-619en_US
dc.identifier.issn0033-6572en_US
dc.identifier.urihttp://hdl.handle.net/10722/154117-
dc.description.abstractRecent clinical studies show 2-unit cantilevered resin-bonded fixed partial dentures to be as retentive or more retentive than their fixed-fixed counterparts. The fact that the 2-unit prosthesis is successful adds value to the clinical use of resin-bonded fixed partial dentures because the single-abutment prosthesis is even simpler and more cost effective than fixed-fixed designs. However, there is no evidence-based information relating to design principles for abutment preparation and framework design for the single-abutment, single-retainer prosthesis. The aim of this report is to suggest principles of design for the 2-unit cantilevered fixed partial denture, based on information gained from studies on fixed-fixed designs.en_US
dc.languageengen_US
dc.publisherQuintessence Publishing Co, Inc. The Journal's web site is located at http://www.quintpub.comen_US
dc.relation.ispartofQuintessence Internationalen_US
dc.subjectAbutment-
dc.subjectCantilevered-
dc.subjectFixed partial dentures-
dc.subjectFixed-fixed design-
dc.subjectResin-bonded-
dc.subject.meshCost-Benefit Analysisen_US
dc.subject.meshDental Abutmentsen_US
dc.subject.meshDental Occlusionen_US
dc.subject.meshDental Prosthesis Designen_US
dc.subject.meshDenture Design - Classification - Economicsen_US
dc.subject.meshDenture Retentionen_US
dc.subject.meshDenture, Partial, Fixed - Classification - Economicsen_US
dc.subject.meshDenture, Partial, Fixed, Resin-Bonded - Classification - Economicsen_US
dc.subject.meshHumansen_US
dc.subject.meshStress, Mechanicalen_US
dc.subject.meshSurface Propertiesen_US
dc.subject.meshTooth Preparation, Prosthodonticen_US
dc.titleDesign principles for cantilevered resin-bonded fixed partial denturesen_US
dc.typeArticleen_US
dc.identifier.emailBotelho, M:botelho@hkucc.hku.hken_US
dc.identifier.authorityBotelho, M=rp00033en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.pmid11203985-
dc.identifier.scopuseid_2-s2.0-0034302632en_US
dc.identifier.hkuros57966-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034302632&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume31en_US
dc.identifier.issue9en_US
dc.identifier.spage613en_US
dc.identifier.epage619en_US
dc.identifier.isiWOS:000165199800004-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridBotelho, M=7005751169en_US
dc.identifier.issnl0033-6572-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats