AbstractThere has been little reported on the strength of phosphate-bonded investments, and in particular the role of 'special liquids' in this context is poorly understood. Using a novel test design, sequential testing of an investment diaphragm using a variable casting metal mass, a measure of the effect of 'special liquid' on strength under actual casting conditions has been obtained. The use of special liquid was found to increase substantially the strength of the four products tested. This test may provide more useful data than the conventional compressive strength test, which may give misleading information, especially if performed at room temperature. © 1991.
Persistent Identifierhttp://hdl.handle.net/10722/153748
ISSN
2023 Impact Factor: 4.6
2023 SCImago Journal Rankings: 1.186
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLuk, HWKen_HK
dc.contributor.authorDarvell, BWen_HK
dc.date.accessioned2012-08-08T08:21:22Z-
dc.date.available2012-08-08T08:21:22Z-
dc.date.issued1991en_HK
dc.identifier.citationDental Materials, 1991, v. 7 n. 2, p. 99-102en_HK
dc.identifier.issn0109-5641en_HK
dc.identifier.urihttp://hdl.handle.net/10722/153748-
dc.description.abstractThere has been little reported on the strength of phosphate-bonded investments, and in particular the role of 'special liquids' in this context is poorly understood. Using a novel test design, sequential testing of an investment diaphragm using a variable casting metal mass, a measure of the effect of 'special liquid' on strength under actual casting conditions has been obtained. The use of special liquid was found to increase substantially the strength of the four products tested. This test may provide more useful data than the conventional compressive strength test, which may give misleading information, especially if performed at room temperature. © 1991.en_HK
dc.languageengen_US
dc.publisherElsevier Inc. The Journal's web site is located at http://www.elsevier.com/locate/dentalen_HK
dc.relation.ispartofDental Materialsen_HK
dc.subject.meshDental Bondingen_US
dc.subject.meshDental Casting Investmenten_US
dc.subject.meshDental Casting Techniqueen_US
dc.subject.meshHot Temperatureen_US
dc.subject.meshMaterials Testing - Methodsen_US
dc.subject.meshPhosphatesen_US
dc.subject.meshSolutionsen_US
dc.subject.meshTensile Strengthen_US
dc.titleStrength of phosphate-bonded investments at high temperatureen_HK
dc.typeArticleen_HK
dc.identifier.emailLuk, HWK: wkluka@hkucc.hku.hken_HK
dc.identifier.emailDarvell, BW: b.w.darvell@hku.hken_HK
dc.identifier.authorityLuk, HWK=rp00008en_HK
dc.identifier.authorityDarvell, BW=rp00007en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/0109-5641(91)90053-2-
dc.identifier.pmid1936648en_HK
dc.identifier.scopuseid_2-s2.0-0026149808en_HK
dc.identifier.volume7en_HK
dc.identifier.issue2en_HK
dc.identifier.spage99en_HK
dc.identifier.epage102en_HK
dc.identifier.isiWOS:A1991FF35300005-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridLuk, HWK=7006636056en_HK
dc.identifier.scopusauthoridDarvell, BW=7005953926en_HK
dc.identifier.issnl0109-5641-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats