Article: A study of the clinical fit of cast cobalt-chromium clasps

TitleA study of the clinical fit of cast cobalt-chromium clasps
Authors
KeywordsCobalt-chromium clasps
Fit
Gauge
Issue Date1988
PublisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdent
Citation
Journal Of Dentistry, 1988, v. 16 n. 3, p. 135-139 How to Cite?
AbstractA clinical study was conducted to assess the fit of cobalt-chromium clasps on newly inserted dentures, and on dentures which had been worn for periods of 6, 12 and 24 months. Special gauges were designed and constructed, and were used to measure the gaps between clasps and teeth in the mouths of patients who had had removable partial dentures fitted at the Prince Philip Dental Hospital, Hong Kong. Many gaps were detected at the time of insertion in relation to clasps previously thought to be of acceptable fit. Statistical analysis of the data was carried out with a view to identifying any effects on the mean gap between clasp and tooth, related to time or design factors. No time-dependent effect was revealed in this study, except when other factors supervened. © 1988.
Persistent Identifierhttp://hdl.handle.net/10722/153655
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.313
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorMurray, MDen_US
dc.contributor.authorDyson, JEen_US
dc.date.accessioned2012-08-08T08:20:52Z-
dc.date.available2012-08-08T08:20:52Z-
dc.date.issued1988en_US
dc.identifier.citationJournal Of Dentistry, 1988, v. 16 n. 3, p. 135-139en_US
dc.identifier.issn0300-5712en_US
dc.identifier.urihttp://hdl.handle.net/10722/153655-
dc.description.abstractA clinical study was conducted to assess the fit of cobalt-chromium clasps on newly inserted dentures, and on dentures which had been worn for periods of 6, 12 and 24 months. Special gauges were designed and constructed, and were used to measure the gaps between clasps and teeth in the mouths of patients who had had removable partial dentures fitted at the Prince Philip Dental Hospital, Hong Kong. Many gaps were detected at the time of insertion in relation to clasps previously thought to be of acceptable fit. Statistical analysis of the data was carried out with a view to identifying any effects on the mean gap between clasp and tooth, related to time or design factors. No time-dependent effect was revealed in this study, except when other factors supervened. © 1988.en_US
dc.languageengen_US
dc.publisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdenten_US
dc.relation.ispartofJournal of Dentistryen_US
dc.subjectCobalt-chromium clasps-
dc.subjectFit-
dc.subjectGauge-
dc.subject.meshChromium Alloysen_US
dc.subject.meshDental Abutmentsen_US
dc.subject.meshDenture Designen_US
dc.subject.meshDenture Retentionen_US
dc.subject.meshDenture, Partial, Removableen_US
dc.subject.meshHumansen_US
dc.subject.meshSurface Propertiesen_US
dc.titleA study of the clinical fit of cast cobalt-chromium claspsen_US
dc.typeArticleen_US
dc.identifier.emailDyson, JE:jdyson@hkucc.hku.hken_US
dc.identifier.authorityDyson, JE=rp00003en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/0300-5712(88)90008-5-
dc.identifier.pmid3045174en_US
dc.identifier.scopuseid_2-s2.0-0024024475en_US
dc.identifier.volume16en_US
dc.identifier.issue3en_US
dc.identifier.spage135en_US
dc.identifier.epage139en_US
dc.identifier.isiWOS:A1988P110800006-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridMurray, MD=7403583901en_US
dc.identifier.scopusauthoridDyson, JE=23089868600en_US
dc.identifier.issnl0300-5712-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats