File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: Shift of the effective centroid of channel columns
Title | Shift of the effective centroid of channel columns |
---|---|
Authors | |
Issue Date | 1998 |
Citation | International Specialty Conference On Cold-Formed Steel Structures: Recent Research And Developments In Cold-Formed Steel Design And Construction, 1998, p. 265-287 How to Cite? |
Abstract | An approach to predict the direction and magnitude of the shift of the effective centroid of the cold formed steel structures was discussed. The shift of the effective centroid as predicted by the current design rules was shown to be accurate for plain channels but inaccurate for lipped channel with slender flanges. It was observed that the current design strength curve for lipped channel with slender flanges increased with increasing effective length. It was emphasized that in the design of pin-ended channel columns, it is necessary to account for the shift of the effective centroid caused by local buckling. |
Persistent Identifier | http://hdl.handle.net/10722/152136 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Young, B | en_US |
dc.contributor.author | Rasmussen, KJR | en_US |
dc.date.accessioned | 2012-06-26T06:35:29Z | - |
dc.date.available | 2012-06-26T06:35:29Z | - |
dc.date.issued | 1998 | en_US |
dc.identifier.citation | International Specialty Conference On Cold-Formed Steel Structures: Recent Research And Developments In Cold-Formed Steel Design And Construction, 1998, p. 265-287 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/152136 | - |
dc.description.abstract | An approach to predict the direction and magnitude of the shift of the effective centroid of the cold formed steel structures was discussed. The shift of the effective centroid as predicted by the current design rules was shown to be accurate for plain channels but inaccurate for lipped channel with slender flanges. It was observed that the current design strength curve for lipped channel with slender flanges increased with increasing effective length. It was emphasized that in the design of pin-ended channel columns, it is necessary to account for the shift of the effective centroid caused by local buckling. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | International Specialty Conference on Cold-Formed Steel Structures: Recent Research and Developments in Cold-Formed Steel Design and Construction | en_US |
dc.title | Shift of the effective centroid of channel columns | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Young, B:young@hku.hk | en_US |
dc.identifier.authority | Young, B=rp00208 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-3042606249 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-3042606249&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.spage | 265 | en_US |
dc.identifier.epage | 287 | en_US |
dc.identifier.scopusauthorid | Young, B=7402192398 | en_US |
dc.identifier.scopusauthorid | Rasmussen, KJR=7402496265 | en_US |