File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/S1350-4487(00)00132-3
- Scopus: eid_2-s2.0-0034744547
- WOS: WOS:000166370100007
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Improvement of the equivalent dose determination using aliquots of potassium feldspar
Title | Improvement of the equivalent dose determination using aliquots of potassium feldspar |
---|---|
Authors | |
Issue Date | 2001 |
Publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeas |
Citation | Radiation Measurements, 2001, v. 33 n. 1, p. 65-71 How to Cite? |
Abstract | A procedure of preheat/measurement, dose/preheat/measurement and preheat/measurement is proposed, in which all the measurements for the equivalent dose determination are made on a single aliquot of K-feldspar sample with the additive-dose method. Correction for the loss of IRSL signal due to preheat/measurement cycles is made using correction factors determined both at the beginning and the end of the measurement cycle. It is suggested that the optimal preheat condition for the sample can be determined by comparing the correction factors obtained from the two stages of analysis, as a function of preheat temperature. The most appropriate preheat for our K-feldspar sample is at 235°C for 10 min. © 2001 Elsevier Science Ltd. |
Persistent Identifier | http://hdl.handle.net/10722/151046 |
ISSN | 2023 Impact Factor: 1.6 2023 SCImago Journal Rankings: 0.463 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhang, JF | en_US |
dc.contributor.author | Li, SH | en_US |
dc.contributor.author | Tso, MYW | en_US |
dc.date.accessioned | 2012-06-26T06:16:28Z | - |
dc.date.available | 2012-06-26T06:16:28Z | - |
dc.date.issued | 2001 | en_US |
dc.identifier.citation | Radiation Measurements, 2001, v. 33 n. 1, p. 65-71 | en_US |
dc.identifier.issn | 1350-4487 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/151046 | - |
dc.description.abstract | A procedure of preheat/measurement, dose/preheat/measurement and preheat/measurement is proposed, in which all the measurements for the equivalent dose determination are made on a single aliquot of K-feldspar sample with the additive-dose method. Correction for the loss of IRSL signal due to preheat/measurement cycles is made using correction factors determined both at the beginning and the end of the measurement cycle. It is suggested that the optimal preheat condition for the sample can be determined by comparing the correction factors obtained from the two stages of analysis, as a function of preheat temperature. The most appropriate preheat for our K-feldspar sample is at 235°C for 10 min. © 2001 Elsevier Science Ltd. | en_US |
dc.language | eng | en_US |
dc.publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/radmeas | en_US |
dc.relation.ispartof | Radiation Measurements | en_US |
dc.title | Improvement of the equivalent dose determination using aliquots of potassium feldspar | en_US |
dc.type | Article | en_US |
dc.identifier.email | Li, SH:shli@hku.hk | en_US |
dc.identifier.authority | Li, SH=rp00740 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1016/S1350-4487(00)00132-3 | en_US |
dc.identifier.scopus | eid_2-s2.0-0034744547 | en_US |
dc.identifier.hkuros | 63410 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0034744547&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 33 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.spage | 65 | en_US |
dc.identifier.epage | 71 | en_US |
dc.identifier.isi | WOS:000166370100007 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Zhang, JF=7601338769 | en_US |
dc.identifier.scopusauthorid | Li, SH=24438103700 | en_US |
dc.identifier.scopusauthorid | Tso, MYW=7102052118 | en_US |
dc.identifier.issnl | 1350-4487 | - |