File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1088/0022-3727/33/4/318
- Scopus: eid_2-s2.0-0033873586
- WOS: WOS:000085742300020
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Studies of quartz 110 °C thermoluminescence peak sensitivity change and its relevance to optically stimulated luminescence dating
Title | Studies of quartz 110 °C thermoluminescence peak sensitivity change and its relevance to optically stimulated luminescence dating |
---|---|
Authors | |
Issue Date | 2000 |
Publisher | Institute of Physics Publishing. The Journal's web site is located at http://www.iop.org/Journals/jpd |
Citation | Journal Of Physics D: Applied Physics, 2000, v. 33 n. 4, p. 437-443 How to Cite? |
Abstract | The sensitivity changes of the 110 °C TL peak in response to temperature, time, irradiation dose and UV exposure were studied. The observations are explained by a modified model with proposed existence of multiple levels of holes (R traps). It is found that the degree of the sensitivity change, and hence the OSL efficiency, relates to many factors. The relevance of the 110 °C TL peak to OSL dating is discussed. |
Persistent Identifier | http://hdl.handle.net/10722/151034 |
ISSN | 2023 Impact Factor: 3.1 2023 SCImago Journal Rankings: 0.681 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chen, G | en_US |
dc.contributor.author | Li, SH | en_US |
dc.date.accessioned | 2012-06-26T06:16:19Z | - |
dc.date.available | 2012-06-26T06:16:19Z | - |
dc.date.issued | 2000 | en_US |
dc.identifier.citation | Journal Of Physics D: Applied Physics, 2000, v. 33 n. 4, p. 437-443 | en_US |
dc.identifier.issn | 0022-3727 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/151034 | - |
dc.description.abstract | The sensitivity changes of the 110 °C TL peak in response to temperature, time, irradiation dose and UV exposure were studied. The observations are explained by a modified model with proposed existence of multiple levels of holes (R traps). It is found that the degree of the sensitivity change, and hence the OSL efficiency, relates to many factors. The relevance of the 110 °C TL peak to OSL dating is discussed. | en_US |
dc.language | eng | en_US |
dc.publisher | Institute of Physics Publishing. The Journal's web site is located at http://www.iop.org/Journals/jpd | en_US |
dc.relation.ispartof | Journal of Physics D: Applied Physics | en_US |
dc.title | Studies of quartz 110 °C thermoluminescence peak sensitivity change and its relevance to optically stimulated luminescence dating | en_US |
dc.type | Article | en_US |
dc.identifier.email | Li, SH: shli@hku.hk | en_US |
dc.identifier.authority | Li, SH=rp00740 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1088/0022-3727/33/4/318 | en_US |
dc.identifier.scopus | eid_2-s2.0-0033873586 | en_US |
dc.identifier.hkuros | 63427 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0033873586&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 33 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.spage | 437 | en_US |
dc.identifier.epage | 443 | en_US |
dc.identifier.isi | WOS:000085742300020 | - |
dc.publisher.place | United Kingdom | en_US |
dc.identifier.scopusauthorid | Chen, G=7407505500 | en_US |
dc.identifier.scopusauthorid | Li, SH=24438103700 | en_US |
dc.identifier.issnl | 0022-3727 | - |