File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/SENSOR.2007.4300106
- Scopus: eid_2-s2.0-50049113028
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: A three dimensional real-time MEMS based optical biopsy system for in-vivo clinical imaging
Title | A three dimensional real-time MEMS based optical biopsy system for in-vivo clinical imaging |
---|---|
Authors | |
Keywords | 3D imaging Bio-photonics In-vivo imaging Micro-electromechanical systems (MEMS) Minimally invasive imaging Optical coherence tomography (OCT) |
Issue Date | 2007 |
Citation | Transducers And Eurosensors '07 - 4Th International Conference On Solid-State Sensors, Actuators And Microsystems, 2007, p. 203-208 How to Cite? |
Abstract | In this work we present our latest "optical biopsy" system realized via MEMS based optical coherence tomography imaging. We report, for the first time, real-time 3-D optical biopsies of human internal organs employing a miniature MEMS based endoscopic probe in a clinical environment. We also present a variety of MEMS imaging probes, each designed for a particular application area. Leveraging the unique advantages of specific OCT systems with properly optimized MEMS probes we are able to achieve truly optimal results for individual clinical and research applications. Artifact free images with 5μm×5μm×5μm sampling resolution (10μm×10μ m×10μm optical) at speeds of 33μs per voxel are achieved. ©2007 IEEE. |
Persistent Identifier | http://hdl.handle.net/10722/149025 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | McCormick, DT | en_HK |
dc.contributor.author | Jung, W | en_HK |
dc.contributor.author | Ahn, YC | en_HK |
dc.contributor.author | Chen, Z | en_HK |
dc.contributor.author | Tien, NC | en_HK |
dc.date.accessioned | 2012-06-20T06:17:57Z | - |
dc.date.available | 2012-06-20T06:17:57Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Transducers And Eurosensors '07 - 4Th International Conference On Solid-State Sensors, Actuators And Microsystems, 2007, p. 203-208 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/149025 | - |
dc.description.abstract | In this work we present our latest "optical biopsy" system realized via MEMS based optical coherence tomography imaging. We report, for the first time, real-time 3-D optical biopsies of human internal organs employing a miniature MEMS based endoscopic probe in a clinical environment. We also present a variety of MEMS imaging probes, each designed for a particular application area. Leveraging the unique advantages of specific OCT systems with properly optimized MEMS probes we are able to achieve truly optimal results for individual clinical and research applications. Artifact free images with 5μm×5μm×5μm sampling resolution (10μm×10μ m×10μm optical) at speeds of 33μs per voxel are achieved. ©2007 IEEE. | en_HK |
dc.language | eng | en_US |
dc.relation.ispartof | TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems | en_HK |
dc.subject | 3D imaging | en_HK |
dc.subject | Bio-photonics | en_HK |
dc.subject | In-vivo imaging | en_HK |
dc.subject | Micro-electromechanical systems (MEMS) | en_HK |
dc.subject | Minimally invasive imaging | en_HK |
dc.subject | Optical coherence tomography (OCT) | en_HK |
dc.title | A three dimensional real-time MEMS based optical biopsy system for in-vivo clinical imaging | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Tien, NC: nctien@hku.hk | en_HK |
dc.identifier.authority | Tien, NC=rp01604 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1109/SENSOR.2007.4300106 | en_HK |
dc.identifier.scopus | eid_2-s2.0-50049113028 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-50049113028&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.spage | 203 | en_HK |
dc.identifier.epage | 208 | en_HK |
dc.identifier.scopusauthorid | McCormick, DT=7202521902 | en_HK |
dc.identifier.scopusauthorid | Jung, W=7201622408 | en_HK |
dc.identifier.scopusauthorid | Ahn, YC=8917906700 | en_HK |
dc.identifier.scopusauthorid | Chen, Z=7409482950 | en_HK |
dc.identifier.scopusauthorid | Tien, NC=7006532826 | en_HK |