File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: The Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airways

TitleThe Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airways
Authors
KeywordsAirway
Bronchoscope
Endoscopy
Endotracheal intubation
Fiberoptic bronchoscopy
Issue Date2004
PublisherLippincott Williams & Wilkins. The Journal's web site is located at http://www.co-anesthesiology.com
Citation
Current Opinion in Anaesthesiology, 2004, v. 17 n. 6, p. 505-510 How to Cite?
AbstractPURPOSE OF REVIEW: In this article we will summarize the available information on airways that have been suggested to provide a conduit for the bronchoscope in its passage through the upper airway during fibreoptic intubation. RECENT FINDINGS: The Williams Airway Intubator and the Berman Oropharyngeal Airway appear to be more likely to provide a conduit for the bronchoscope than the Ovassapian Fibreoptic Intubating Airway. SUMMARY: Though the Williams Airway Intubator and the Berman Oropharyngeal Airway are superior in this role, all the airways discussed here have major deficiencies in their function. Further research is needed in this field to meet the requirements of endoscopists in situations when it is crucial that equipment reliably fulfils its function.
Persistent Identifierhttp://hdl.handle.net/10722/145537
ISSN
2021 Impact Factor: 2.733
2020 SCImago Journal Rankings: 0.738
References

 

DC FieldValueLanguage
dc.contributor.authorGreenland, KBen_HK
dc.contributor.authorIrwin, MGen_HK
dc.date.accessioned2012-02-28T01:53:17Z-
dc.date.available2012-02-28T01:53:17Z-
dc.date.issued2004en_HK
dc.identifier.citationCurrent Opinion in Anaesthesiology, 2004, v. 17 n. 6, p. 505-510en_HK
dc.identifier.issn0952-7907en_HK
dc.identifier.urihttp://hdl.handle.net/10722/145537-
dc.description.abstractPURPOSE OF REVIEW: In this article we will summarize the available information on airways that have been suggested to provide a conduit for the bronchoscope in its passage through the upper airway during fibreoptic intubation. RECENT FINDINGS: The Williams Airway Intubator and the Berman Oropharyngeal Airway appear to be more likely to provide a conduit for the bronchoscope than the Ovassapian Fibreoptic Intubating Airway. SUMMARY: Though the Williams Airway Intubator and the Berman Oropharyngeal Airway are superior in this role, all the airways discussed here have major deficiencies in their function. Further research is needed in this field to meet the requirements of endoscopists in situations when it is crucial that equipment reliably fulfils its function.en_HK
dc.languageengen_US
dc.publisherLippincott Williams & Wilkins. The Journal's web site is located at http://www.co-anesthesiology.comen_HK
dc.relation.ispartofCurrent Opinion in Anaesthesiologyen_HK
dc.rightsThis is a non-final version of an article published in final form in (provide complete journal citation)en_US
dc.subjectAirwayen_HK
dc.subjectBronchoscopeen_HK
dc.subjectEndoscopyen_HK
dc.subjectEndotracheal intubationen_HK
dc.subjectFiberoptic bronchoscopy-
dc.titleThe Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airwaysen_HK
dc.typeArticleen_HK
dc.identifier.emailGreenland, KB: green@hkucc.hku.hken_HK
dc.identifier.emailIrwin, MG: mgirwin@hkucc.hku.hk-
dc.identifier.authorityIrwin, MG=rp00390en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1097/00001503-200412000-00010en_HK
dc.identifier.pmid17031085-
dc.identifier.scopuseid_2-s2.0-10344247197en_HK
dc.identifier.hkuros97322en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-10344247197&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume17en_HK
dc.identifier.issue6en_HK
dc.identifier.spage505en_HK
dc.identifier.epage510en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.issnl0952-7907-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats