File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1097/00001503-200412000-00010
- Scopus: eid_2-s2.0-10344247197
- PMID: 17031085
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: The Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airways
Title | The Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airways |
---|---|
Authors | |
Keywords | Airway Bronchoscope Endoscopy Endotracheal intubation Fiberoptic bronchoscopy |
Issue Date | 2004 |
Publisher | Lippincott Williams & Wilkins. The Journal's web site is located at http://www.co-anesthesiology.com |
Citation | Current Opinion in Anaesthesiology, 2004, v. 17 n. 6, p. 505-510 How to Cite? |
Abstract | PURPOSE OF REVIEW: In this article we will summarize the available information on airways that have been suggested to provide a conduit for the bronchoscope in its passage through the upper airway during fibreoptic intubation. RECENT FINDINGS: The Williams Airway Intubator and the Berman Oropharyngeal Airway appear to be more likely to provide a conduit for the bronchoscope than the Ovassapian Fibreoptic Intubating Airway. SUMMARY: Though the Williams Airway Intubator and the Berman Oropharyngeal Airway are superior in this role, all the airways discussed here have major deficiencies in their function. Further research is needed in this field to meet the requirements of endoscopists in situations when it is crucial that equipment reliably fulfils its function. |
Persistent Identifier | http://hdl.handle.net/10722/145537 |
ISSN | 2023 Impact Factor: 2.3 2023 SCImago Journal Rankings: 0.650 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Greenland, KB | en_HK |
dc.contributor.author | Irwin, MG | en_HK |
dc.date.accessioned | 2012-02-28T01:53:17Z | - |
dc.date.available | 2012-02-28T01:53:17Z | - |
dc.date.issued | 2004 | en_HK |
dc.identifier.citation | Current Opinion in Anaesthesiology, 2004, v. 17 n. 6, p. 505-510 | en_HK |
dc.identifier.issn | 0952-7907 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/145537 | - |
dc.description.abstract | PURPOSE OF REVIEW: In this article we will summarize the available information on airways that have been suggested to provide a conduit for the bronchoscope in its passage through the upper airway during fibreoptic intubation. RECENT FINDINGS: The Williams Airway Intubator and the Berman Oropharyngeal Airway appear to be more likely to provide a conduit for the bronchoscope than the Ovassapian Fibreoptic Intubating Airway. SUMMARY: Though the Williams Airway Intubator and the Berman Oropharyngeal Airway are superior in this role, all the airways discussed here have major deficiencies in their function. Further research is needed in this field to meet the requirements of endoscopists in situations when it is crucial that equipment reliably fulfils its function. | en_HK |
dc.language | eng | en_US |
dc.publisher | Lippincott Williams & Wilkins. The Journal's web site is located at http://www.co-anesthesiology.com | en_HK |
dc.relation.ispartof | Current Opinion in Anaesthesiology | en_HK |
dc.rights | This is a non-final version of an article published in final form in (provide complete journal citation) | en_US |
dc.subject | Airway | en_HK |
dc.subject | Bronchoscope | en_HK |
dc.subject | Endoscopy | en_HK |
dc.subject | Endotracheal intubation | en_HK |
dc.subject | Fiberoptic bronchoscopy | - |
dc.title | The Williams Airway Intubator, the Ovassapian Airway and the Berman Airway as upper airway conduits for fibreoptic bronchoscopy in patients with difficult airways | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Greenland, KB: green@hkucc.hku.hk | en_HK |
dc.identifier.email | Irwin, MG: mgirwin@hkucc.hku.hk | - |
dc.identifier.authority | Irwin, MG=rp00390 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1097/00001503-200412000-00010 | en_HK |
dc.identifier.pmid | 17031085 | - |
dc.identifier.scopus | eid_2-s2.0-10344247197 | en_HK |
dc.identifier.hkuros | 97322 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-10344247197&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 17 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 505 | en_HK |
dc.identifier.epage | 510 | en_HK |
dc.publisher.place | United States | en_HK |
dc.identifier.issnl | 0952-7907 | - |