File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.nima.2006.08.084
- Scopus: eid_2-s2.0-33750835652
- WOS: WOS:000242822900033
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A further study of the (CR-LR) difference technique for retrospective radon exposure assessment
Title | A further study of the (CR-LR) difference technique for retrospective radon exposure assessment |
---|---|
Authors | |
Keywords | 210Po Implantation Radon Radon progeny Retrospective dosimetry |
Issue Date | 2006 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nima |
Citation | Nuclear Instruments And Methods In Physics Research, Section A: Accelerators, Spectrometers, Detectors And Associated Equipment, 2006, v. 568 n. 2, p. 792-798 How to Cite? |
Abstract | The (CR-LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted 210Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiments. The dependency of the sensitivity ratio on the removed layer of both detectors was determined and verified experimentally. The simulated sensitivity ratios correlate well with the experimental ones. A major finding of the present work is that the sensitivity ratio between the CR-39 and LR 115 detectors depends only weakly on the ratio between the 238U and 232Th concentrations in the glass samples. This is crucial for the application of the (CR-LR) difference technique for retrospective radon exposure assessments, since measurements of the 238U and 232Th concentrations in the relatively small real-life glass samples will make the retrospective radon exposure assessments impractical. © 2006 Elsevier B.V. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/143784 |
ISSN | 2023 Impact Factor: 1.5 2023 SCImago Journal Rankings: 0.514 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nikezic, D | en_HK |
dc.contributor.author | Yip, CWY | en_HK |
dc.contributor.author | Leung, SYY | en_HK |
dc.contributor.author | Leung, JKC | en_HK |
dc.contributor.author | Yu, KN | en_HK |
dc.date.accessioned | 2011-12-21T08:55:14Z | - |
dc.date.available | 2011-12-21T08:55:14Z | - |
dc.date.issued | 2006 | en_HK |
dc.identifier.citation | Nuclear Instruments And Methods In Physics Research, Section A: Accelerators, Spectrometers, Detectors And Associated Equipment, 2006, v. 568 n. 2, p. 792-798 | en_HK |
dc.identifier.issn | 0168-9002 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/143784 | - |
dc.description.abstract | The (CR-LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted 210Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiments. The dependency of the sensitivity ratio on the removed layer of both detectors was determined and verified experimentally. The simulated sensitivity ratios correlate well with the experimental ones. A major finding of the present work is that the sensitivity ratio between the CR-39 and LR 115 detectors depends only weakly on the ratio between the 238U and 232Th concentrations in the glass samples. This is crucial for the application of the (CR-LR) difference technique for retrospective radon exposure assessments, since measurements of the 238U and 232Th concentrations in the relatively small real-life glass samples will make the retrospective radon exposure assessments impractical. © 2006 Elsevier B.V. All rights reserved. | en_HK |
dc.language | eng | en_US |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nima | en_HK |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_HK |
dc.subject | 210Po | en_HK |
dc.subject | Implantation | en_HK |
dc.subject | Radon | en_HK |
dc.subject | Radon progeny | en_HK |
dc.subject | Retrospective dosimetry | en_HK |
dc.title | A further study of the (CR-LR) difference technique for retrospective radon exposure assessment | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Leung, JKC: jkcleung@hku.hk | en_HK |
dc.identifier.authority | Leung, JKC=rp00732 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.nima.2006.08.084 | en_HK |
dc.identifier.scopus | eid_2-s2.0-33750835652 | en_HK |
dc.identifier.hkuros | 198153 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-33750835652&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 568 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 792 | en_HK |
dc.identifier.epage | 798 | en_HK |
dc.identifier.isi | WOS:000242822900033 | - |
dc.publisher.place | Netherlands | en_HK |
dc.identifier.scopusauthorid | Nikezic, D=35614145500 | en_HK |
dc.identifier.scopusauthorid | Yip, CWY=7101665531 | en_HK |
dc.identifier.scopusauthorid | Leung, SYY=55168680800 | en_HK |
dc.identifier.scopusauthorid | Leung, JKC=24080627200 | en_HK |
dc.identifier.scopusauthorid | Yu, KN=7403385896 | en_HK |
dc.identifier.issnl | 0168-9002 | - |