File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A further study of the (CR-LR) difference technique for retrospective radon exposure assessment

TitleA further study of the (CR-LR) difference technique for retrospective radon exposure assessment
Authors
Keywords210Po
Implantation
Radon
Radon progeny
Retrospective dosimetry
Issue Date2006
PublisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nima
Citation
Nuclear Instruments And Methods In Physics Research, Section A: Accelerators, Spectrometers, Detectors And Associated Equipment, 2006, v. 568 n. 2, p. 792-798 How to Cite?
AbstractThe (CR-LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted 210Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiments. The dependency of the sensitivity ratio on the removed layer of both detectors was determined and verified experimentally. The simulated sensitivity ratios correlate well with the experimental ones. A major finding of the present work is that the sensitivity ratio between the CR-39 and LR 115 detectors depends only weakly on the ratio between the 238U and 232Th concentrations in the glass samples. This is crucial for the application of the (CR-LR) difference technique for retrospective radon exposure assessments, since measurements of the 238U and 232Th concentrations in the relatively small real-life glass samples will make the retrospective radon exposure assessments impractical. © 2006 Elsevier B.V. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/143784
ISSN
2023 Impact Factor: 1.5
2023 SCImago Journal Rankings: 0.514
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorNikezic, Den_HK
dc.contributor.authorYip, CWYen_HK
dc.contributor.authorLeung, SYYen_HK
dc.contributor.authorLeung, JKCen_HK
dc.contributor.authorYu, KNen_HK
dc.date.accessioned2011-12-21T08:55:14Z-
dc.date.available2011-12-21T08:55:14Z-
dc.date.issued2006en_HK
dc.identifier.citationNuclear Instruments And Methods In Physics Research, Section A: Accelerators, Spectrometers, Detectors And Associated Equipment, 2006, v. 568 n. 2, p. 792-798en_HK
dc.identifier.issn0168-9002en_HK
dc.identifier.urihttp://hdl.handle.net/10722/143784-
dc.description.abstractThe (CR-LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted 210Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiments. The dependency of the sensitivity ratio on the removed layer of both detectors was determined and verified experimentally. The simulated sensitivity ratios correlate well with the experimental ones. A major finding of the present work is that the sensitivity ratio between the CR-39 and LR 115 detectors depends only weakly on the ratio between the 238U and 232Th concentrations in the glass samples. This is crucial for the application of the (CR-LR) difference technique for retrospective radon exposure assessments, since measurements of the 238U and 232Th concentrations in the relatively small real-life glass samples will make the retrospective radon exposure assessments impractical. © 2006 Elsevier B.V. All rights reserved.en_HK
dc.languageengen_US
dc.publisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nimaen_HK
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_HK
dc.subject210Poen_HK
dc.subjectImplantationen_HK
dc.subjectRadonen_HK
dc.subjectRadon progenyen_HK
dc.subjectRetrospective dosimetryen_HK
dc.titleA further study of the (CR-LR) difference technique for retrospective radon exposure assessmenten_HK
dc.typeArticleen_HK
dc.identifier.emailLeung, JKC: jkcleung@hku.hken_HK
dc.identifier.authorityLeung, JKC=rp00732en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.nima.2006.08.084en_HK
dc.identifier.scopuseid_2-s2.0-33750835652en_HK
dc.identifier.hkuros198153en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33750835652&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume568en_HK
dc.identifier.issue2en_HK
dc.identifier.spage792en_HK
dc.identifier.epage798en_HK
dc.identifier.isiWOS:000242822900033-
dc.publisher.placeNetherlandsen_HK
dc.identifier.scopusauthoridNikezic, D=35614145500en_HK
dc.identifier.scopusauthoridYip, CWY=7101665531en_HK
dc.identifier.scopusauthoridLeung, SYY=55168680800en_HK
dc.identifier.scopusauthoridLeung, JKC=24080627200en_HK
dc.identifier.scopusauthoridYu, KN=7403385896en_HK
dc.identifier.issnl0168-9002-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats