File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Transoral robotic resection of recurrent nasopharyngeal carcinoma

TitleTransoral robotic resection of recurrent nasopharyngeal carcinoma
Authors
KeywordsNasopharyngectomy
Recurrent nasopharyngeal cancer
Robotic surgery
Issue Date2010
PublisherJohn Wiley & Sons, Inc. The Journal's web site is located at http://www.laryngoscope.com/
Citation
Laryngoscope, 2010, v. 120 n. 10, p. 2011-2014 How to Cite?
AbstractTransoral robotic nasopharyngectomy was carried out for a patient who developed recurrent nasopharyngeal cancer after radiotherapy. The tumor in the left lateral wall of the nasopharynx was exposed after splitting the soft palate and a curative resection, including the medial crus of the eustachian tube was carried out under the three-dimensional 0° camera. The operative procedure was uncomplicated, blood loss was minimal and the patient recovered smoothly. The camera of the surgical robot provided superb visualization of the operative field and the maneuverability of the robotic arms with the Endowrist design allowed adequate tumor extirpation. The morbidity associated with the procedure was minimal, and this surgical procedure can be applied for resection of small and favorably located residual or recurrent nasopharyngeal cancer or other appropriate pathologies in the region. © 2010 The American Laryngological, Rhinological and Otological Society, Inc.
Persistent Identifierhttp://hdl.handle.net/10722/142529
ISSN
2023 Impact Factor: 2.2
2023 SCImago Journal Rankings: 1.128
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorWei, WIen_HK
dc.contributor.authorHo, WKen_HK
dc.date.accessioned2011-10-28T02:50:31Z-
dc.date.available2011-10-28T02:50:31Z-
dc.date.issued2010en_HK
dc.identifier.citationLaryngoscope, 2010, v. 120 n. 10, p. 2011-2014en_HK
dc.identifier.issn0023-852Xen_HK
dc.identifier.urihttp://hdl.handle.net/10722/142529-
dc.description.abstractTransoral robotic nasopharyngectomy was carried out for a patient who developed recurrent nasopharyngeal cancer after radiotherapy. The tumor in the left lateral wall of the nasopharynx was exposed after splitting the soft palate and a curative resection, including the medial crus of the eustachian tube was carried out under the three-dimensional 0° camera. The operative procedure was uncomplicated, blood loss was minimal and the patient recovered smoothly. The camera of the surgical robot provided superb visualization of the operative field and the maneuverability of the robotic arms with the Endowrist design allowed adequate tumor extirpation. The morbidity associated with the procedure was minimal, and this surgical procedure can be applied for resection of small and favorably located residual or recurrent nasopharyngeal cancer or other appropriate pathologies in the region. © 2010 The American Laryngological, Rhinological and Otological Society, Inc.en_HK
dc.languageengen_US
dc.publisherJohn Wiley & Sons, Inc. The Journal's web site is located at http://www.laryngoscope.com/en_HK
dc.relation.ispartofLaryngoscopeen_HK
dc.rightsThe Laryngoscope. Copyright © John Wiley & Sons, Inc.-
dc.subjectNasopharyngectomyen_HK
dc.subjectRecurrent nasopharyngeal canceren_HK
dc.subjectRobotic surgeryen_HK
dc.subject.meshNasopharyngeal Neoplasms - surgery-
dc.subject.meshOtorhinolaryngologic Surgical Procedures - instrumentation-
dc.subject.meshPalate - surgery-
dc.subject.meshPharyngectomy - methods-
dc.subject.meshRobotics - instrumentation - methods-
dc.titleTransoral robotic resection of recurrent nasopharyngeal carcinomaen_HK
dc.typeArticleen_HK
dc.identifier.emailWei, WI: hrmswwi@hku.hken_HK
dc.identifier.authorityWei, WI=rp00323en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1002/lary.21059en_HK
dc.identifier.pmid20824741-
dc.identifier.scopuseid_2-s2.0-78649895941en_HK
dc.identifier.hkuros184423en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-78649895941&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume120en_HK
dc.identifier.issue10en_HK
dc.identifier.spage2011en_HK
dc.identifier.epage2014en_HK
dc.identifier.isiWOS:000282743100018-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridWei, WI=7403321552en_HK
dc.identifier.scopusauthoridHo, WK=7402968844en_HK
dc.identifier.issnl0023-852X-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats