File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Coreless PCB transformers with multiple secondary windings for complementary gate drive circuits

TitleCoreless PCB transformers with multiple secondary windings for complementary gate drive circuits
Authors
KeywordsBridge Circuits
Power Converters
Power Electronics
Printed Circuit Boards
Issue Date1998
PublisherIEEE
Citation
Pesc Record - Ieee Annual Power Electronics Specialists Conference, 1998, v. 2, p. 1965-1971 How to Cite?
AbstractThis paper describes the modeling and implementation of coreless PCB-based transformer with `multiple' secondary outputs. This new PCB-transformer has been successfully applied in complementary gate drive circuits in a novel low-profile power converter with high power density and converter bridge. The PCB-based transformers do not require the manual winding procedure and thus simplifies the manufacturing process of transformer isolated gate drive circuits. The use of the multiple secondary outputs can in principle simplify the complementary gate drive circuits that are often required in many power electronics applications.
Persistent Identifierhttp://hdl.handle.net/10722/136877
ISSN
2019 SCImago Journal Rankings: 0.125

 

DC FieldValueLanguage
dc.contributor.authorTang, SCen_HK
dc.contributor.authorHui, SYRen_HK
dc.contributor.authorChung, Hen_HK
dc.date.accessioned2011-07-29T02:13:17Z-
dc.date.available2011-07-29T02:13:17Z-
dc.date.issued1998en_HK
dc.identifier.citationPesc Record - Ieee Annual Power Electronics Specialists Conference, 1998, v. 2, p. 1965-1971en_HK
dc.identifier.issn0275-9306en_HK
dc.identifier.urihttp://hdl.handle.net/10722/136877-
dc.description.abstractThis paper describes the modeling and implementation of coreless PCB-based transformer with `multiple' secondary outputs. This new PCB-transformer has been successfully applied in complementary gate drive circuits in a novel low-profile power converter with high power density and converter bridge. The PCB-based transformers do not require the manual winding procedure and thus simplifies the manufacturing process of transformer isolated gate drive circuits. The use of the multiple secondary outputs can in principle simplify the complementary gate drive circuits that are often required in many power electronics applications.en_HK
dc.languageengen_US
dc.publisherIEEEen_US
dc.relation.ispartofPESC Record - IEEE Annual Power Electronics Specialists Conferenceen_HK
dc.subjectBridge Circuitsen_US
dc.subjectPower Convertersen_US
dc.subjectPower Electronicsen_US
dc.subjectPrinted Circuit Boardsen_US
dc.titleCoreless PCB transformers with multiple secondary windings for complementary gate drive circuitsen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailHui, SYR:ronhui@eee.hku.hken_HK
dc.identifier.authorityHui, SYR=rp01510en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/PESC.1998.703449en_HK
dc.identifier.scopuseid_2-s2.0-0031624333en_HK
dc.identifier.volume2en_HK
dc.identifier.spage1965en_HK
dc.identifier.epage1971en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTang, SC=24340444700en_HK
dc.identifier.scopusauthoridHui, SYR=7202831744en_HK
dc.identifier.scopusauthoridChung, H=7404007467en_HK
dc.identifier.issnl0275-9306-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats