File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Some electromagnetic aspects of coreless PCB transformers

TitleSome electromagnetic aspects of coreless PCB transformers
Authors
KeywordsElectromagnetic Wave Interference
Frequencies
Magnetic Cores
Magnetic Couplings
Power Electronics
Printed Circuit Boards
Transients
Issue Date1999
PublisherIEEE
Citation
Pesc Record - Ieee Annual Power Electronics Specialists Conference, 1999, v. 2, p. 868-873 How to Cite?
AbstractIn this paper, some EMI aspects of using coreless PCB transformers are addressed. Based on the antenna theory, the radiated power of a coreless PCB transformer is estimated and found to be negligible. The electromagnetic field plot of a power electronic circuit using a gate drive circuit isolated with coreless PCB transformer has been recorded. The major radiated EMI source in the frequency range of 30MHz to 300MHz is found to be the copper tracks of the power circuit, where switching transients occur, rather than the coreless PCB transformer. Coreless PCB transformers essentially operate at relatively low frequency (8MHz in this case) by near-field magnetic coupling. Experimental results have confirmed that the application of coreless PCB transformer in gate drive circuit for power electronic circuit will not impose any serious EMI problem on the power electronic circuit.
Persistent Identifierhttp://hdl.handle.net/10722/136853
ISSN
2019 SCImago Journal Rankings: 0.125

 

DC FieldValueLanguage
dc.contributor.authorHui, SYRen_HK
dc.contributor.authorTang, SCen_HK
dc.contributor.authorChung, Hen_HK
dc.date.accessioned2011-07-29T02:13:09Z-
dc.date.available2011-07-29T02:13:09Z-
dc.date.issued1999en_HK
dc.identifier.citationPesc Record - Ieee Annual Power Electronics Specialists Conference, 1999, v. 2, p. 868-873en_HK
dc.identifier.issn0275-9306en_HK
dc.identifier.urihttp://hdl.handle.net/10722/136853-
dc.description.abstractIn this paper, some EMI aspects of using coreless PCB transformers are addressed. Based on the antenna theory, the radiated power of a coreless PCB transformer is estimated and found to be negligible. The electromagnetic field plot of a power electronic circuit using a gate drive circuit isolated with coreless PCB transformer has been recorded. The major radiated EMI source in the frequency range of 30MHz to 300MHz is found to be the copper tracks of the power circuit, where switching transients occur, rather than the coreless PCB transformer. Coreless PCB transformers essentially operate at relatively low frequency (8MHz in this case) by near-field magnetic coupling. Experimental results have confirmed that the application of coreless PCB transformer in gate drive circuit for power electronic circuit will not impose any serious EMI problem on the power electronic circuit.en_HK
dc.languageengen_US
dc.publisherIEEEen_US
dc.relation.ispartofPESC Record - IEEE Annual Power Electronics Specialists Conferenceen_HK
dc.subjectElectromagnetic Wave Interferenceen_US
dc.subjectFrequenciesen_US
dc.subjectMagnetic Coresen_US
dc.subjectMagnetic Couplingsen_US
dc.subjectPower Electronicsen_US
dc.subjectPrinted Circuit Boardsen_US
dc.subjectTransientsen_US
dc.titleSome electromagnetic aspects of coreless PCB transformersen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailHui, SYR:ronhui@eee.hku.hken_HK
dc.identifier.authorityHui, SYR=rp01510en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/PESC.1999.785613en_HK
dc.identifier.scopuseid_2-s2.0-0033346172en_HK
dc.identifier.volume2en_HK
dc.identifier.spage868en_HK
dc.identifier.epage873en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridHui, SYR=7202831744en_HK
dc.identifier.scopusauthoridTang, SC=24340444700en_HK
dc.identifier.scopusauthoridChung, H=7404007467en_HK
dc.identifier.issnl0275-9306-

Export via OAI-PMH Interface in XML Formats