Conference Paper: Diffusion-weighted balanced SSFP (DW-bSSFP): a new approach to diffusion tensor imaging

TitleDiffusion-weighted balanced SSFP (DW-bSSFP): a new approach to diffusion tensor imaging
Authors
Issue Date2010
Citation
The ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May 2010. How to Cite?
AbstractAlthough DW-EPI offers high acquisition speed, it generally suffers from low spatial resolution and geometric distortion. SSFP is a possible alternative to perform diffusion imaging with higher resolution and with no distortion artifacts that is inherent in EPI. In this study, we modified the balanced SSFP sequence by adding a pair of bipolar diffusion sensitizing gradients. The diffusion effect in bSSFP sequence with a pair of bipolar diffusion gradients was formulated and DW-bSSFP experiment was performed on in vivo rat brain at 7T.
DescriptionPosters - Diffusion MRI: No. 4003
Persistent Identifierhttp://hdl.handle.net/10722/129729

 

DC FieldValueLanguage
dc.contributor.authorCheung, MMHen_US
dc.contributor.authorCheung, JSCen_US
dc.contributor.authorXiao, Len_US
dc.contributor.authorChow, AMKen_US
dc.contributor.authorChan, KWYen_US
dc.contributor.authorWu, EXen_US
dc.date.accessioned2010-12-23T08:41:19Z-
dc.date.available2010-12-23T08:41:19Z-
dc.date.issued2010en_US
dc.identifier.citationThe ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May 2010.en_US
dc.identifier.urihttp://hdl.handle.net/10722/129729-
dc.descriptionPosters - Diffusion MRI: No. 4003-
dc.description.abstractAlthough DW-EPI offers high acquisition speed, it generally suffers from low spatial resolution and geometric distortion. SSFP is a possible alternative to perform diffusion imaging with higher resolution and with no distortion artifacts that is inherent in EPI. In this study, we modified the balanced SSFP sequence by adding a pair of bipolar diffusion sensitizing gradients. The diffusion effect in bSSFP sequence with a pair of bipolar diffusion gradients was formulated and DW-bSSFP experiment was performed on in vivo rat brain at 7T.-
dc.languageengen_US
dc.relation.ispartofISMRM-ESMRMB Joint Annual Meeting-
dc.titleDiffusion-weighted balanced SSFP (DW-bSSFP): a new approach to diffusion tensor imagingen_US
dc.typeConference_Paperen_US