File Download
Supplementary
-
Citations:
- Appears in Collections:
Conference Paper: Cross infection in a hospital ward and deposition of particles exhaled from a source patient
Title | Cross infection in a hospital ward and deposition of particles exhaled from a source patient |
---|---|
Authors | |
Issue Date | 2009 |
Citation | The 5th International Workshop on Energy and Environment of Residential Buildings and the 3rd International Conference on Built Environment and Public Health (EERB-BEPH 2009), Guilin, China, 29-31 May 2009, How to Cite? 第五届居住建筑能源与环境国际研讨会 (EERB) & 第三届建筑环境与公共健康国际学术会议 (BEPH), 中国, 桂林, 2009年5月29至31日. How to Cite? |
Abstract | The cross infection in a hospital ward is studied. Deposition of particles exhaled from a source manikin is investigated in a full-scale hospital ward ventilated by downward directed ventilation. Deposition on vertical surfaces close to the source shows distribution of particles directed upwards in the room. Deposition at the four beds shows that particles smaller than 10 μm disperse evenly in the ward, indicating that particles smaller than this size are airborne. The influence of top and bottom extraction openings on dispersion of particles is investigated. Results show that vertical distribution in the room is not affected by the position of the return openings. Deposition of particles at the four beds gives some indication of a less wide spread of particles with the use of ceiling-mounted return openings, and thereby a better protection of patients compared with bottom return openings. |
Persistent Identifier | http://hdl.handle.net/10722/126291 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nielsen, PV | en_HK |
dc.contributor.author | Li, Y | en_HK |
dc.contributor.author | Buus, M | en_HK |
dc.contributor.author | Winther, FV | en_HK |
dc.contributor.author | Qian, H | - |
dc.date.accessioned | 2010-10-31T12:20:21Z | - |
dc.date.available | 2010-10-31T12:20:21Z | - |
dc.date.issued | 2009 | en_HK |
dc.identifier.citation | The 5th International Workshop on Energy and Environment of Residential Buildings and the 3rd International Conference on Built Environment and Public Health (EERB-BEPH 2009), Guilin, China, 29-31 May 2009, | en_HK |
dc.identifier.citation | 第五届居住建筑能源与环境国际研讨会 (EERB) & 第三届建筑环境与公共健康国际学术会议 (BEPH), 中国, 桂林, 2009年5月29至31日. | zh_HK |
dc.identifier.uri | http://hdl.handle.net/10722/126291 | - |
dc.description.abstract | The cross infection in a hospital ward is studied. Deposition of particles exhaled from a source manikin is investigated in a full-scale hospital ward ventilated by downward directed ventilation. Deposition on vertical surfaces close to the source shows distribution of particles directed upwards in the room. Deposition at the four beds shows that particles smaller than 10 μm disperse evenly in the ward, indicating that particles smaller than this size are airborne. The influence of top and bottom extraction openings on dispersion of particles is investigated. Results show that vertical distribution in the room is not affected by the position of the return openings. Deposition of particles at the four beds gives some indication of a less wide spread of particles with the use of ceiling-mounted return openings, and thereby a better protection of patients compared with bottom return openings. | - |
dc.language | eng | en_HK |
dc.relation.ispartof | International Workshop on Energy and Environment of Residential Buildings | - |
dc.relation.ispartof | International Conference on Built Environment and Public Health | - |
dc.relation.ispartof | 居住建筑能源与环境国际研讨会 (EERB) | zh_HK |
dc.relation.ispartof | 建筑环境与公共健康国际学术会议 (BEPH) | zh_HK |
dc.title | Cross infection in a hospital ward and deposition of particles exhaled from a source patient | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Nielsen, PV: pvn@civil.aau.dk | en_HK |
dc.identifier.email | Li, Y: liyg@hku.hk | - |
dc.identifier.email | Qian, H: keenwah@hku.hk | - |
dc.identifier.authority | Li, Y=rp00151 | en_HK |
dc.description.nature | postprint | - |
dc.identifier.hkuros | 180446 | en_HK |
dc.description.other | The 5th International Workshop on Energy and Environment of Residential Buildings and the 3rd International Conference on Built Environment and Public Health (EERB-BEPH 2009), Guilin, China, 29-31 May 2009, | - |
dc.description.other | 第五届居住建筑能源与环境国际研讨会 (EERB) & 第三届建筑环境与公共健康国际学术会议 (BEPH), 中国, 桂林, 2009年5月29至31日. | - |