Abstract | A modified accelerated forced aeration composting process was investigated to improve the rate and extent of organic wastes degradation. Composting tests were performed in two stages of 20 to 30 days duration each, using either a single reactor or a two-reactor system. Temperature at different depths of the composting mass, air velocity and pressure were continuously monitored by the datalogger. Air flow was continuous or intermittent depending on temperature. Oxygen content in the spent air was regularly measured. The product stability was determined by the self-heating test. |
Persistent Identifier | http://hdl.handle.net/10722/111773 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Koenig, Albert | en_HK |
dc.contributor.author | Bari, Quazi H | en_HK |
dc.date.accessioned | 2010-09-26T03:03:21Z | - |
dc.date.available | 2010-09-26T03:03:21Z | - |
dc.date.issued | 1998 | en_HK |
dc.identifier.citation | Proceedings Of The Air & Waste Management Association's Annual Meeting & Exhibition, 1998, p. 14pp | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/111773 | - |
dc.description.abstract | A modified accelerated forced aeration composting process was investigated to improve the rate and extent of organic wastes degradation. Composting tests were performed in two stages of 20 to 30 days duration each, using either a single reactor or a two-reactor system. Temperature at different depths of the composting mass, air velocity and pressure were continuously monitored by the datalogger. Air flow was continuous or intermittent depending on temperature. Oxygen content in the spent air was regularly measured. The product stability was determined by the self-heating test. | en_HK |
dc.language | eng | en_HK |
dc.relation.ispartof | Proceedings of the Air & Waste Management Association's Annual Meeting & Exhibition | en_HK |
dc.title | Effect of air recirculation on single-reactor and two-reactor composting system | en_HK |
dc.type | Conference_Paper | en_HK |
dc.identifier.email | Koenig, Albert:kalbert@hkucc.hku.hk | en_HK |
dc.identifier.authority | Koenig, Albert=rp00125 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.scopus | eid_2-s2.0-18244429075 | en_HK |
dc.identifier.hkuros | 33640 | en_HK |
dc.identifier.spage | 14pp | en_HK |
dc.identifier.epage | 14pp | en_HK |
dc.identifier.scopusauthorid | Koenig, Albert=7103178143 | en_HK |
dc.identifier.scopusauthorid | Bari, Quazi H=6506028117 | en_HK |