File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: Effect of air recirculation on single-reactor and two-reactor composting system

TitleEffect of air recirculation on single-reactor and two-reactor composting system
Authors
Issue Date1998
Citation
Proceedings Of The Air & Waste Management Association's Annual Meeting & Exhibition, 1998, p. 14pp How to Cite?
AbstractA modified accelerated forced aeration composting process was investigated to improve the rate and extent of organic wastes degradation. Composting tests were performed in two stages of 20 to 30 days duration each, using either a single reactor or a two-reactor system. Temperature at different depths of the composting mass, air velocity and pressure were continuously monitored by the datalogger. Air flow was continuous or intermittent depending on temperature. Oxygen content in the spent air was regularly measured. The product stability was determined by the self-heating test.
Persistent Identifierhttp://hdl.handle.net/10722/111773

 

DC FieldValueLanguage
dc.contributor.authorKoenig, Alberten_HK
dc.contributor.authorBari, Quazi Hen_HK
dc.date.accessioned2010-09-26T03:03:21Z-
dc.date.available2010-09-26T03:03:21Z-
dc.date.issued1998en_HK
dc.identifier.citationProceedings Of The Air & Waste Management Association's Annual Meeting & Exhibition, 1998, p. 14ppen_HK
dc.identifier.urihttp://hdl.handle.net/10722/111773-
dc.description.abstractA modified accelerated forced aeration composting process was investigated to improve the rate and extent of organic wastes degradation. Composting tests were performed in two stages of 20 to 30 days duration each, using either a single reactor or a two-reactor system. Temperature at different depths of the composting mass, air velocity and pressure were continuously monitored by the datalogger. Air flow was continuous or intermittent depending on temperature. Oxygen content in the spent air was regularly measured. The product stability was determined by the self-heating test.en_HK
dc.languageengen_HK
dc.relation.ispartofProceedings of the Air & Waste Management Association's Annual Meeting & Exhibitionen_HK
dc.titleEffect of air recirculation on single-reactor and two-reactor composting systemen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailKoenig, Albert:kalbert@hkucc.hku.hken_HK
dc.identifier.authorityKoenig, Albert=rp00125en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-18244429075en_HK
dc.identifier.hkuros33640en_HK
dc.identifier.spage14ppen_HK
dc.identifier.epage14ppen_HK
dc.identifier.scopusauthoridKoenig, Albert=7103178143en_HK
dc.identifier.scopusauthoridBari, Quazi H=6506028117en_HK

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats