Article: Atrial sensing and pacing with a single pass ventricular lead

TitleAtrial sensing and pacing with a single pass ventricular lead
Authors
Issue Date1998
PublisherChinese Medical Association. The Journal's web site is located at http://www.cmj.org/
Citation
Chinese Medical Journal, 1998, v. 111 n. 12, p. 1118-1123 How to Cite?
AbstractThe use of single lead for atrial synchronous ventricular (VDD) pacing in patients with high grade atrioventricular (AV) block and normal sinus node function is an acceptable alternative to dual chamber (ODD) pacing. Implantation and follow up procedures are simplified, and cost is usually reduced by more than the cost of an additional atrial lead. With the use of either diagonally arranged dipole or closely spaced ring electrodes, reliable atrial sensing can be achieved using differential atrial amplifier and high atrial sensitivity. Also oversensing is infrequently observed using provocation tests and dynamic recordings, clinical undersensing is unusual and minimized by programming to the highest atrial sensitivity. However, as atrial pacing is not possible, loss of AV synchrony and rate response may occur for unrecognized or progressive sinus node disease and lower rate limit. The development of single lead dual chamber pacing system may overcome this limitation. Recent studies have demonstrated that atrial pacing can be effective either with the use of a special pacing lead configuration or via floating atrial electrode with a novel stimulation method. Overlapping biphasic impulse (OLBI) can reduce atrial pacing threshold. Early clinical experience suggested that this new pacing method can provide effective and reliable atrial pacing with a relatively low incidence of diaphragmatic pacing. Thus the problem of atrial sensing is solved with a single pass lead but further long term evaluation is required to assess the efficacy and feasibility of new instrumentation for single lead dual chamber pacing.
Persistent Identifierhttp://hdl.handle.net/10722/101696
ISSN
2023 Impact Factor: 7.5
2023 SCImago Journal Rankings: 0.997
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorTse, HFen_HK
dc.contributor.authorLau, CPen_HK
dc.date.accessioned2010-09-25T20:00:08Z-
dc.date.available2010-09-25T20:00:08Z-
dc.date.issued1998en_HK
dc.identifier.citationChinese Medical Journal, 1998, v. 111 n. 12, p. 1118-1123en_HK
dc.identifier.issn0366-6999en_HK
dc.identifier.urihttp://hdl.handle.net/10722/101696-
dc.description.abstractThe use of single lead for atrial synchronous ventricular (VDD) pacing in patients with high grade atrioventricular (AV) block and normal sinus node function is an acceptable alternative to dual chamber (ODD) pacing. Implantation and follow up procedures are simplified, and cost is usually reduced by more than the cost of an additional atrial lead. With the use of either diagonally arranged dipole or closely spaced ring electrodes, reliable atrial sensing can be achieved using differential atrial amplifier and high atrial sensitivity. Also oversensing is infrequently observed using provocation tests and dynamic recordings, clinical undersensing is unusual and minimized by programming to the highest atrial sensitivity. However, as atrial pacing is not possible, loss of AV synchrony and rate response may occur for unrecognized or progressive sinus node disease and lower rate limit. The development of single lead dual chamber pacing system may overcome this limitation. Recent studies have demonstrated that atrial pacing can be effective either with the use of a special pacing lead configuration or via floating atrial electrode with a novel stimulation method. Overlapping biphasic impulse (OLBI) can reduce atrial pacing threshold. Early clinical experience suggested that this new pacing method can provide effective and reliable atrial pacing with a relatively low incidence of diaphragmatic pacing. Thus the problem of atrial sensing is solved with a single pass lead but further long term evaluation is required to assess the efficacy and feasibility of new instrumentation for single lead dual chamber pacing.en_HK
dc.languageengen_HK
dc.publisherChinese Medical Association. The Journal's web site is located at http://www.cmj.org/en_HK
dc.relation.ispartofChinese Medical Journalen_HK
dc.subject.meshCardiac Pacing, Artificial - methodsen_HK
dc.subject.meshHeart Block - therapyen_HK
dc.subject.meshHumansen_HK
dc.subject.meshPacemaker, Artificialen_HK
dc.titleAtrial sensing and pacing with a single pass ventricular leaden_HK
dc.typeArticleen_HK
dc.identifier.emailTse, HF:hftse@hkucc.hku.hken_HK
dc.identifier.authorityTse, HF=rp00428en_HK
dc.description.naturelink_to_OA_fulltext-
dc.identifier.pmid11263378-
dc.identifier.scopuseid_2-s2.0-0042762737en_HK
dc.identifier.hkuros41437en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0042762737&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume111en_HK
dc.identifier.issue12en_HK
dc.identifier.spage1118en_HK
dc.identifier.epage1123en_HK
dc.identifier.isiWOS:000077982700020-
dc.publisher.placeChinaen_HK
dc.identifier.scopusauthoridTse, HF=7006070805en_HK
dc.identifier.scopusauthoridLau, CP=7401968501en_HK
dc.identifier.issnl0366-6999-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats