postgraduate thesis: Development of the customized radon detector and studies of the radon background onsite for the Daya Bay reactor neutrino experiment

TitleDevelopment of the customized radon detector and studies of the radon background onsite for the Daya Bay reactor neutrino experiment
Authors
Advisors
Issue Date2013
PublisherThe University of Hong Kong (Pokfulam, Hong Kong)
Citation
Leung, K. [梁嘉怡]. (2013). Development of the customized radon detector and studies of the radon background onsite for the Daya Bay reactor neutrino experiment. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b5053415
AbstractThe goal of the Daya Bay Reactor Neutrino Experiment is to determine the last unknown neutrino mixing angle θ13, in sin22θ13 to sensitivity better than 0.01 at 90% confidential level in three years of running. In order to reach the goal, background from natural radiation should be controlled less than 50 Hz, accordingly radon, which is a naturally-occurring radioactive gas, is one of the factors need to be monitored. A High-sensitivity and High-reliability Hong Kong (H3) radon monitoring system is developed to support the slow control system of the experiment. It achieves the sensitivity requirement and fulfills the data acquisition specification by using an enlarged sample chamber, an improved electronic and a designed software, in addition to the dehumidifier system for long term use. Four final products of the radon detector were well calibrated and tested before application; the sensitivities of counted progenies Po-218 and Po-214 are 3.65 ± 0.37 x10-2 cpm/Bq·m3 (C.F.is 27.4±2.7 Bq/m3/cpm) and 3.94 ±0.40 x10-2 cpm/Bq·m3 (C.F. is 25.4±2.5 Bq/m3/cpm). Its performance is the highest among the same type of commercial available products. This radon monitoring system has been successfully taking data as the background measurement of the experiment for more than half a year, and will continue to provide useful information for the following several years. From the results, the radon levels in the air in Experimental Halls and in the water of water systems were higher than expected, but still at the acceptable levels. Further works have to be done to control them at preferred levels.
DegreeMaster of Philosophy
SubjectRadon measures.
Dept/ProgramPhysics
Persistent Identifierhttp://hdl.handle.net/10722/188296
HKU Library Item IDb5053415

 

DC FieldValueLanguage
dc.contributor.advisorLeung, JKC-
dc.contributor.advisorPun, JCS-
dc.contributor.authorLeung, Kar-yee-
dc.contributor.author梁嘉怡-
dc.date.accessioned2013-08-27T08:03:23Z-
dc.date.available2013-08-27T08:03:23Z-
dc.date.issued2013-
dc.identifier.citationLeung, K. [梁嘉怡]. (2013). Development of the customized radon detector and studies of the radon background onsite for the Daya Bay reactor neutrino experiment. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b5053415-
dc.identifier.urihttp://hdl.handle.net/10722/188296-
dc.description.abstractThe goal of the Daya Bay Reactor Neutrino Experiment is to determine the last unknown neutrino mixing angle θ13, in sin22θ13 to sensitivity better than 0.01 at 90% confidential level in three years of running. In order to reach the goal, background from natural radiation should be controlled less than 50 Hz, accordingly radon, which is a naturally-occurring radioactive gas, is one of the factors need to be monitored. A High-sensitivity and High-reliability Hong Kong (H3) radon monitoring system is developed to support the slow control system of the experiment. It achieves the sensitivity requirement and fulfills the data acquisition specification by using an enlarged sample chamber, an improved electronic and a designed software, in addition to the dehumidifier system for long term use. Four final products of the radon detector were well calibrated and tested before application; the sensitivities of counted progenies Po-218 and Po-214 are 3.65 ± 0.37 x10-2 cpm/Bq·m3 (C.F.is 27.4±2.7 Bq/m3/cpm) and 3.94 ±0.40 x10-2 cpm/Bq·m3 (C.F. is 25.4±2.5 Bq/m3/cpm). Its performance is the highest among the same type of commercial available products. This radon monitoring system has been successfully taking data as the background measurement of the experiment for more than half a year, and will continue to provide useful information for the following several years. From the results, the radon levels in the air in Experimental Halls and in the water of water systems were higher than expected, but still at the acceptable levels. Further works have to be done to control them at preferred levels.-
dc.languageeng-
dc.publisherThe University of Hong Kong (Pokfulam, Hong Kong)-
dc.relation.ispartofHKU Theses Online (HKUTO)-
dc.rightsThe author retains all proprietary rights, (such as patent rights) and the right to use in future works.-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.source.urihttp://hub.hku.hk/bib/B50534154-
dc.subject.lcshRadon measures.-
dc.titleDevelopment of the customized radon detector and studies of the radon background onsite for the Daya Bay reactor neutrino experiment-
dc.typePG_Thesis-
dc.identifier.hkulb5053415-
dc.description.thesisnameMaster of Philosophy-
dc.description.thesislevelMaster-
dc.description.thesisdisciplinePhysics-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.5353/th_b5053415-
dc.date.hkucongregation2013-
dc.identifier.mmsid991035481199703414-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats