File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/0022-0728(92)80561-H
- Scopus: eid_2-s2.0-44049112780
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Article: Microfabricated gas-diffusion electrodes
Title | Microfabricated gas-diffusion electrodes |
---|---|
Authors | |
Issue Date | 1992 |
Citation | Journal Of Electroanalytical Chemistry, 1992, v. 334 n. 1-2, p. 65-80 How to Cite? |
Abstract | Gas-diffusion electrodes with uniform openings were prepared by electrodeposition of silver on microfabricated metal mesh. The porous metallic structures were non-wetting and allowed operating pressures up to 2 atm (0.2 MPa). From the polarization data for oxygen reduction on these electrodes, the decrease in contact angle with pressure reported in an earlier study was confirmed. The wedge meniscus model was used to analyse the results, and revealed the effects of various structural and operating parameters. © 1992. |
Persistent Identifier | http://hdl.handle.net/10722/168302 |
ISSN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ki Lai Tang, T | en_US |
dc.contributor.author | Chan, KY | en_US |
dc.date.accessioned | 2012-10-08T03:17:14Z | - |
dc.date.available | 2012-10-08T03:17:14Z | - |
dc.date.issued | 1992 | en_US |
dc.identifier.citation | Journal Of Electroanalytical Chemistry, 1992, v. 334 n. 1-2, p. 65-80 | en_US |
dc.identifier.issn | 0022-0728 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/168302 | - |
dc.description.abstract | Gas-diffusion electrodes with uniform openings were prepared by electrodeposition of silver on microfabricated metal mesh. The porous metallic structures were non-wetting and allowed operating pressures up to 2 atm (0.2 MPa). From the polarization data for oxygen reduction on these electrodes, the decrease in contact angle with pressure reported in an earlier study was confirmed. The wedge meniscus model was used to analyse the results, and revealed the effects of various structural and operating parameters. © 1992. | en_US |
dc.language | eng | en_US |
dc.relation.ispartof | Journal of Electroanalytical Chemistry | en_US |
dc.title | Microfabricated gas-diffusion electrodes | en_US |
dc.type | Article | en_US |
dc.identifier.email | Chan, KY:hrsccky@hku.hk | en_US |
dc.identifier.authority | Chan, KY=rp00662 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1016/0022-0728(92)80561-H | - |
dc.identifier.scopus | eid_2-s2.0-44049112780 | en_US |
dc.identifier.volume | 334 | en_US |
dc.identifier.issue | 1-2 | en_US |
dc.identifier.spage | 65 | en_US |
dc.identifier.epage | 80 | en_US |
dc.identifier.scopusauthorid | Ki Lai Tang, T=24317002900 | en_US |
dc.identifier.scopusauthorid | Chan, KY=7406034142 | en_US |
dc.identifier.issnl | 0022-0728 | - |