Article: Energization-Status Identification of Three-Phase Three-Core Shielded Distribution Power Cables Based on Non-Destructive Magnetic Field Sensing

TitleEnergization-Status Identification of Three-Phase Three-Core Shielded Distribution Power Cables Based on Non-Destructive Magnetic Field Sensing
Authors
Keywordsdistribution power network
energized status
magnetic sensing
Three-phase three-core distribution power cable
Issue Date2017
PublisherIEEE. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=7361
Citation
IEEE Sensors Journal, 2017, v. 17 n. 22, p. 7405-7417 How to Cite?
Persistent Identifierhttp://hdl.handle.net/10722/259270
ISSN
2021 Impact Factor: 4.325
2020 SCImago Journal Rankings: 0.681
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorPong, PWT-
dc.contributor.authorLee, WK-
dc.contributor.authorZhu, K-
dc.date.accessioned2018-09-03T04:04:11Z-
dc.date.available2018-09-03T04:04:11Z-
dc.date.issued2017-
dc.identifier.citationIEEE Sensors Journal, 2017, v. 17 n. 22, p. 7405-7417-
dc.identifier.issn1530-437X-
dc.identifier.urihttp://hdl.handle.net/10722/259270-
dc.languageeng-
dc.publisherIEEE. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=7361-
dc.relation.ispartofIEEE Sensors Journal-
dc.rightsIEEE Sensors Journal. Copyright © IEEE.-
dc.rights©20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. -
dc.subjectdistribution power network-
dc.subjectenergized status-
dc.subjectmagnetic sensing-
dc.subjectThree-phase three-core distribution power cable-
dc.titleEnergization-Status Identification of Three-Phase Three-Core Shielded Distribution Power Cables Based on Non-Destructive Magnetic Field Sensing-
dc.typeArticle-
dc.identifier.emailPong, PWT: ppong@hkucc.hku.hk-
dc.identifier.emailLee, WK: wklee@eee.hku.hk-
dc.identifier.emailZhu, K: drzhuke@hku.hk-
dc.identifier.authorityPong, PWT=rp00217-
dc.identifier.authorityLee, WK=rp00143-
dc.identifier.doi10.1109/JSEN.2017.2756905-
dc.identifier.scopuseid_2-s2.0-85030755919-
dc.identifier.hkuros288673-
dc.identifier.volume17-
dc.identifier.issue22-
dc.identifier.spage7405-
dc.identifier.epage7417-
dc.identifier.isiWOS:000413948300024-
dc.publisher.placeUnited States-
dc.identifier.issnl1530-437X-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats