Article: A Wearable Detector for Simultaneous Finger Joint Motion Measurement

TitleA Wearable Detector for Simultaneous Finger Joint Motion Measurement
Authors
KeywordsFinger joint motion
Hand goniometry
Sensor array
Stretchable glove
Issue Date2018
PublisherInstitute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=4156126
Citation
IEEE Transactions on Biomedical Circuits and Systems, 2018, v. 12 n. 3, p. 644-654 How to Cite?
AbstractThis paper presents a wearable and stretchable detector for simultaneous finger joint motion measurement, providing the feasible technical solutions to solve the problems existing in the current devices. The sensor array installed in the detector consists of 14 custom-made bending sensors and an inertial measurement unit with high accuracy. The glove support for a sensor array, which is made of three silicone materials with different elasticity, not only overcomes the drawbacks of cloth support, but also addresses the compatibility between the stretch substrate and the inelastic sensing components. Besides, two-section electrical connection avoids the problems caused by the external wires in traditional solutions to enhance the durability of glove. The experiment results indicated that the wearable detector offers a good user experience by exerting a small force on fingers. The device also shows a strong durability as it worked properly after tens of thousands of bending. The measurement tests on a single sensor demonstrated that two kinds of sensors are both with high accuracy. Besides, the hand goniometric system has an excellent performance in terms of hand motion detection. The measurement error of the device in subjects with different hand sizes is within a reasonable range. The good properties of the sensory detector allow it to be applied in clinical applications.
Persistent Identifierhttp://hdl.handle.net/10722/254722
ISSN
2021 Impact Factor: 5.234
2020 SCImago Journal Rankings: 1.020
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLi, X-
dc.contributor.authorWen, R-
dc.contributor.authorShen, Z-
dc.contributor.authorWang, Z-
dc.contributor.authorLuk, KDK-
dc.contributor.authorHu, Y-
dc.date.accessioned2018-06-21T01:05:27Z-
dc.date.available2018-06-21T01:05:27Z-
dc.date.issued2018-
dc.identifier.citationIEEE Transactions on Biomedical Circuits and Systems, 2018, v. 12 n. 3, p. 644-654-
dc.identifier.issn1932-4545-
dc.identifier.urihttp://hdl.handle.net/10722/254722-
dc.description.abstractThis paper presents a wearable and stretchable detector for simultaneous finger joint motion measurement, providing the feasible technical solutions to solve the problems existing in the current devices. The sensor array installed in the detector consists of 14 custom-made bending sensors and an inertial measurement unit with high accuracy. The glove support for a sensor array, which is made of three silicone materials with different elasticity, not only overcomes the drawbacks of cloth support, but also addresses the compatibility between the stretch substrate and the inelastic sensing components. Besides, two-section electrical connection avoids the problems caused by the external wires in traditional solutions to enhance the durability of glove. The experiment results indicated that the wearable detector offers a good user experience by exerting a small force on fingers. The device also shows a strong durability as it worked properly after tens of thousands of bending. The measurement tests on a single sensor demonstrated that two kinds of sensors are both with high accuracy. Besides, the hand goniometric system has an excellent performance in terms of hand motion detection. The measurement error of the device in subjects with different hand sizes is within a reasonable range. The good properties of the sensory detector allow it to be applied in clinical applications.-
dc.languageeng-
dc.publisherInstitute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=4156126-
dc.relation.ispartofIEEE Transactions on Biomedical Circuits and Systems-
dc.rightsIEEE Transactions on Biomedical Circuits and Systems. Copyright © Institute of Electrical and Electronics Engineers.-
dc.subjectFinger joint motion-
dc.subjectHand goniometry-
dc.subjectSensor array-
dc.subjectStretchable glove-
dc.titleA Wearable Detector for Simultaneous Finger Joint Motion Measurement-
dc.typeArticle-
dc.identifier.emailWen, R: rwwen@hku.hk-
dc.identifier.emailWang, Z: zwangski@hku.hk-
dc.identifier.emailLuk, KDK: hrmoldk@hku.hk-
dc.identifier.emailHu, Y: yhud@hku.hk-
dc.identifier.authorityWang, Z=rp01915-
dc.identifier.authorityLuk, KDK=rp00333-
dc.identifier.authorityHu, Y=rp00432-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/TBCAS.2018.2810182-
dc.identifier.pmid29877827-
dc.identifier.scopuseid_2-s2.0-85044071718-
dc.identifier.hkuros285381-
dc.identifier.volume12-
dc.identifier.issue3-
dc.identifier.spage644-
dc.identifier.epage654-
dc.identifier.isiWOS:000434466000019-
dc.publisher.placeUnited States-
dc.identifier.issnl1932-4545-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats