Article: Quantification of Intra-hour Security-constrained Flexibility Region

TitleQuantification of Intra-hour Security-constrained Flexibility Region
Authors
KeywordsContingency analysis
dc power flow
optimal power flow
power system flexibility
robust optimization
Issue Date2017
PublisherInstitute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=5165391
Citation
IEEE Transactions on Sustainable Energy, 2017, v. 8 n. 2, p. 671-684 How to Cite?
AbstractRapid growth of renewable energy sources (RES) in the generation capacity mix poses substantial challenges on the operation of power systems in various time scales. Particularly in the intra-hour time scale, the interplay among variability and uncertainty of RES, unexpected transmission/generation outages, and short dispatch lead time cause difficulties in generation-load balancing. This paper proposes a method to quantify the intra-hour flexibility region. A robust security-constrained multi-period optimal power flow (RSC-OPF) model is first constructed to quantify the frequency, magnitude, and intensity of insufficient flexibility. The randomness of RES is captured by uncertainty sets in this model. The N-k contingency, spinning reserve, and corrective control limit constraints are included. This model is then cast into a two-stage robust optimization (RO) model and solved by the column-and-constraint generation (C&CG) method. The emergency measures with a least number of affected buses are derived and subsequently assessed by the post-optimization sensitivity analysis. Finally, the operational flexibility region is determined by continuous perturbation on the RES penetration level and the forecast error. The IEEE 14-bus system and a realistic Chinese 157-bus system are used to demonstrate the proposed method.
Persistent Identifierhttp://hdl.handle.net/10722/237019
ISSN
2021 Impact Factor: 8.310
2020 SCImago Journal Rankings: 2.771
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorQin, Z-
dc.contributor.authorHou, Y-
dc.contributor.authorLei, S-
dc.contributor.authorLiu, F-
dc.date.accessioned2016-12-20T06:14:58Z-
dc.date.available2016-12-20T06:14:58Z-
dc.date.issued2017-
dc.identifier.citationIEEE Transactions on Sustainable Energy, 2017, v. 8 n. 2, p. 671-684-
dc.identifier.issn1949-3029-
dc.identifier.urihttp://hdl.handle.net/10722/237019-
dc.description.abstractRapid growth of renewable energy sources (RES) in the generation capacity mix poses substantial challenges on the operation of power systems in various time scales. Particularly in the intra-hour time scale, the interplay among variability and uncertainty of RES, unexpected transmission/generation outages, and short dispatch lead time cause difficulties in generation-load balancing. This paper proposes a method to quantify the intra-hour flexibility region. A robust security-constrained multi-period optimal power flow (RSC-OPF) model is first constructed to quantify the frequency, magnitude, and intensity of insufficient flexibility. The randomness of RES is captured by uncertainty sets in this model. The N-k contingency, spinning reserve, and corrective control limit constraints are included. This model is then cast into a two-stage robust optimization (RO) model and solved by the column-and-constraint generation (C&CG) method. The emergency measures with a least number of affected buses are derived and subsequently assessed by the post-optimization sensitivity analysis. Finally, the operational flexibility region is determined by continuous perturbation on the RES penetration level and the forecast error. The IEEE 14-bus system and a realistic Chinese 157-bus system are used to demonstrate the proposed method.-
dc.languageeng-
dc.publisherInstitute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=5165391-
dc.relation.ispartofIEEE Transactions on Sustainable Energy-
dc.rights©2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.-
dc.subjectContingency analysis-
dc.subjectdc power flow-
dc.subjectoptimal power flow-
dc.subjectpower system flexibility-
dc.subjectrobust optimization-
dc.titleQuantification of Intra-hour Security-constrained Flexibility Region-
dc.typeArticle-
dc.identifier.emailQin, Z: zjqin@eee.hku.hk-
dc.identifier.emailHou, Y: yhhou@eee.hku.hk-
dc.identifier.authorityHou, Y=rp00069-
dc.description.naturepostprint-
dc.identifier.doi10.1109/TSTE.2016.2615055-
dc.identifier.scopuseid_2-s2.0-85019175305-
dc.identifier.hkuros270774-
dc.identifier.volume8-
dc.identifier.issue2-
dc.identifier.spage671-
dc.identifier.epage684-
dc.identifier.isiWOS:000398910000022-
dc.publisher.placeUnited States-
dc.identifier.issnl1949-3029-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats