File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Novel Parameter Of Corneal Biomechanics That Differentiate Normals From Glaucoma

TitleNovel Parameter Of Corneal Biomechanics That Differentiate Normals From Glaucoma
Authors
Keywordscorneal biomechanics
Corvis ST
glaucoma
Issue Date2016
Citation
Journal of Glaucoma, 2016, v. 25 n. 6, p. e603-e609 How to Cite?
AbstractPURPOSE: To identify novel corneal biomechanical parameters differentiating glaucomatous from normal eyes. PATIENTS AND METHODS: Sixty subjects with varying degrees of glaucoma severity and 61 normal controls underwent corneal biomechanical measurements including corneal deformation amplitude, inward and outward applanation length and velocity, and highest concavity time in 1 eye per subject at Queen Mary Hospital, Hong Kong. Measurements were taken with the Corvis ST device, a noncontact tonometer coupled with a high-speed Scheimpflug camera. The intraocular pressure (IOP) and central corneal thickness (CCT) were also measured. RESULTS: Significant findings included differences in outward applanation velocity (glaucoma: -0.37±0.01 m/s; control: -0.32±0.01 m/s; P=0.001), peak distance (glaucoma: 2.37±0.03 mm; control: 2.30±0.02 mm; P=0.005), and highest concavity time (glaucoma: 16.75±0.08 ms; control: 17.05±0.07 ms; P=0.002) between the 2 groups, after correcting for IOP, CCT, and age. Both outward applanation velocity and peak distance were moderately correlated with IOP and CCT. However, highest concavity time was not correlated with either IOP or CCT (R=0.0140 and 0.000055, respectively). Age was not correlated with any of the 3 parameters. CONCLUSIONS: Glaucomatous eyes have a greater mean outward applanation velocity and peak distance, but shorter time to highest concavity than eyes without glaucoma. The difference in time to highest concavity does not correlate with age, IOP, or CCT, suggesting that this parameter may be a marker of increased pressure susceptibility that is independently associated with glaucoma risk.
Persistent Identifierhttp://hdl.handle.net/10722/212545
ISSN
2021 Impact Factor: 2.290
2020 SCImago Journal Rankings: 1.110
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLee, RBS-
dc.contributor.authorChang, RT-
dc.contributor.authorWong, IYH-
dc.contributor.authorLai, JSM-
dc.contributor.authorLee, JWY-
dc.contributor.authorSingh, K-
dc.date.accessioned2015-07-21T02:40:14Z-
dc.date.available2015-07-21T02:40:14Z-
dc.date.issued2016-
dc.identifier.citationJournal of Glaucoma, 2016, v. 25 n. 6, p. e603-e609-
dc.identifier.issn1057-0829-
dc.identifier.urihttp://hdl.handle.net/10722/212545-
dc.description.abstractPURPOSE: To identify novel corneal biomechanical parameters differentiating glaucomatous from normal eyes. PATIENTS AND METHODS: Sixty subjects with varying degrees of glaucoma severity and 61 normal controls underwent corneal biomechanical measurements including corneal deformation amplitude, inward and outward applanation length and velocity, and highest concavity time in 1 eye per subject at Queen Mary Hospital, Hong Kong. Measurements were taken with the Corvis ST device, a noncontact tonometer coupled with a high-speed Scheimpflug camera. The intraocular pressure (IOP) and central corneal thickness (CCT) were also measured. RESULTS: Significant findings included differences in outward applanation velocity (glaucoma: -0.37±0.01 m/s; control: -0.32±0.01 m/s; P=0.001), peak distance (glaucoma: 2.37±0.03 mm; control: 2.30±0.02 mm; P=0.005), and highest concavity time (glaucoma: 16.75±0.08 ms; control: 17.05±0.07 ms; P=0.002) between the 2 groups, after correcting for IOP, CCT, and age. Both outward applanation velocity and peak distance were moderately correlated with IOP and CCT. However, highest concavity time was not correlated with either IOP or CCT (R=0.0140 and 0.000055, respectively). Age was not correlated with any of the 3 parameters. CONCLUSIONS: Glaucomatous eyes have a greater mean outward applanation velocity and peak distance, but shorter time to highest concavity than eyes without glaucoma. The difference in time to highest concavity does not correlate with age, IOP, or CCT, suggesting that this parameter may be a marker of increased pressure susceptibility that is independently associated with glaucoma risk.-
dc.languageeng-
dc.relation.ispartofJournal of Glaucoma-
dc.subjectcorneal biomechanics-
dc.subjectCorvis ST-
dc.subjectglaucoma-
dc.titleNovel Parameter Of Corneal Biomechanics That Differentiate Normals From Glaucoma-
dc.typeArticle-
dc.identifier.emailWong, IYH: wongyhi@hku.hk-
dc.identifier.emailLai, JSM: laism@hku.hk-
dc.identifier.emailLee, JWY: jackylee@hku.hk-
dc.identifier.authorityWong, IYH=rp01467-
dc.identifier.authorityLai, JSM=rp00295-
dc.identifier.authorityLee, JWY=rp01498-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1097/IJG.0000000000000284-
dc.identifier.pmid26035421-
dc.identifier.scopuseid_2-s2.0-84975224800-
dc.identifier.hkuros244331-
dc.identifier.volume25-
dc.identifier.issue6-
dc.identifier.spagee603-
dc.identifier.epagee609-
dc.identifier.isiWOS:000379584800007-
dc.identifier.f1000725529812-
dc.identifier.issnl1057-0829-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats