File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: High-resolution section recovery using a configurable pupil in a scanning holographic microscopy

TitleHigh-resolution section recovery using a configurable pupil in a scanning holographic microscopy
Authors
Issue Date2014
PublisherThe Optical Society of America.
Citation
The 2014 Signal Recovery and Synthesis Meeting, Seattle, WA., 13–17 July 2014. In OSA Technical Digest, 2014, paper SM4F.2 How to Cite?
AbstractWe present a sectioning method in optical scanning holography with enhanced depth resolution using a configurable pupil, which is based on spatial light modulator. A depth resolution of 0.7 μm can be achieved by this method. © 2014 OSA
DescriptionImaging and Applied Optics 2014
Session - Holographic Imaging (SM4F): paper SM4F.2
Persistent Identifierhttp://hdl.handle.net/10722/211426
ISBN

 

DC FieldValueLanguage
dc.contributor.authorOu, H-
dc.contributor.authorWong, KKY-
dc.contributor.authorLam, EY-
dc.date.accessioned2015-07-13T06:50:28Z-
dc.date.available2015-07-13T06:50:28Z-
dc.date.issued2014-
dc.identifier.citationThe 2014 Signal Recovery and Synthesis Meeting, Seattle, WA., 13–17 July 2014. In OSA Technical Digest, 2014, paper SM4F.2-
dc.identifier.isbn978-1-55752-308-2-
dc.identifier.urihttp://hdl.handle.net/10722/211426-
dc.descriptionImaging and Applied Optics 2014-
dc.descriptionSession - Holographic Imaging (SM4F): paper SM4F.2-
dc.description.abstractWe present a sectioning method in optical scanning holography with enhanced depth resolution using a configurable pupil, which is based on spatial light modulator. A depth resolution of 0.7 μm can be achieved by this method. © 2014 OSA-
dc.languageeng-
dc.publisherThe Optical Society of America.-
dc.relation.ispartofOSA Technical Digest-
dc.rights© 2014 Optical Society of America. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modifications of the content of this paper are prohibited.-
dc.titleHigh-resolution section recovery using a configurable pupil in a scanning holographic microscopy-
dc.typeConference_Paper-
dc.identifier.emailWong, KKY: kywong@eee.hku.hk-
dc.identifier.emailLam, EY: elam@eee.hku.hk-
dc.identifier.authorityWong, KKY=rp00189-
dc.identifier.authorityLam, EY=rp00131-
dc.description.naturepostprint-
dc.identifier.doi10.1364/SRS.2014.SM4F.2-
dc.identifier.scopuseid_2-s2.0-85086618235-
dc.identifier.hkuros245278-
dc.publisher.placeUnited States-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats