Article: Managing anterior capsule contraction by mechanical widening with vitrectorcut capsulotomy

TitleManaging anterior capsule contraction by mechanical widening with vitrectorcut capsulotomy
Authors
Issue Date2002
PublisherElsevier Inc. The Journal's web site is located at http://www.elsevier.com/locate/jcrs
Citation
Journal Of Cataract And Refractive Surgery, 2002, v. 28 n. 2, p. 217-220 How to Cite?
AbstractWe present a technique, vitrectorhexis, in which a vitrector-cut capsulotomy is used to treat anterior capsule contraction syndrome. A vitrector handpiece is used to remove all fibrous capsule tissue and residual lens epithelia] cells from the anterior chamber. Vitrectorhexis may be an alternative to neodymium: YAG laser capsulotomy as it decreases the risk of radial tear extension to the zonules and of secondary IOL decentration. The technique was used in a 77-year-old man with capsulorhexis contraction syndrome and extensive fibrosis after phacoemulsification with silicone piggyback intraocular lens implantation. One day postoperatively, visual acuity improved from 20/60 to 20/30 and the anterior chamber reaction was minimal. At 1 month, best corrected visual acuity was 20/20. The IOL was well centered at 6 months. © 2002 ASCRS and ESCRS.
Persistent Identifierhttp://hdl.handle.net/10722/176380
ISSN
2021 Impact Factor: 3.528
2020 SCImago Journal Rankings: 1.678
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorYeh, PCen_US
dc.contributor.authorGoins, KMen_US
dc.contributor.authorLai, WWen_US
dc.date.accessioned2012-11-26T09:10:55Z-
dc.date.available2012-11-26T09:10:55Z-
dc.date.issued2002en_US
dc.identifier.citationJournal Of Cataract And Refractive Surgery, 2002, v. 28 n. 2, p. 217-220en_US
dc.identifier.issn0886-3350en_US
dc.identifier.urihttp://hdl.handle.net/10722/176380-
dc.description.abstractWe present a technique, vitrectorhexis, in which a vitrector-cut capsulotomy is used to treat anterior capsule contraction syndrome. A vitrector handpiece is used to remove all fibrous capsule tissue and residual lens epithelia] cells from the anterior chamber. Vitrectorhexis may be an alternative to neodymium: YAG laser capsulotomy as it decreases the risk of radial tear extension to the zonules and of secondary IOL decentration. The technique was used in a 77-year-old man with capsulorhexis contraction syndrome and extensive fibrosis after phacoemulsification with silicone piggyback intraocular lens implantation. One day postoperatively, visual acuity improved from 20/60 to 20/30 and the anterior chamber reaction was minimal. At 1 month, best corrected visual acuity was 20/20. The IOL was well centered at 6 months. © 2002 ASCRS and ESCRS.en_US
dc.languageengen_US
dc.publisherElsevier Inc. The Journal's web site is located at http://www.elsevier.com/locate/jcrsen_US
dc.relation.ispartofJournal of Cataract and Refractive Surgeryen_US
dc.subject.meshAgeden_US
dc.subject.meshAnterior Chamberen_US
dc.subject.meshCapsulorhexis - Adverse Effectsen_US
dc.subject.meshContracture - Etiology - Surgeryen_US
dc.subject.meshHumansen_US
dc.subject.meshLens Capsule, Crystalline - Pathology - Surgeryen_US
dc.subject.meshLens Implantation, Intraocularen_US
dc.subject.meshMaleen_US
dc.subject.meshOphthalmologic Surgical Proceduresen_US
dc.subject.meshPhacoemulsificationen_US
dc.subject.meshPostoperative Complications - Surgeryen_US
dc.subject.meshSyndromeen_US
dc.subject.meshVisual Acuityen_US
dc.titleManaging anterior capsule contraction by mechanical widening with vitrectorcut capsulotomyen_US
dc.typeArticleen_US
dc.identifier.emailLai, WW: wicolai@hku.hken_US
dc.identifier.authorityLai, WW=rp00531en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/S0886-3350(01)01031-8en_US
dc.identifier.pmid11821198-
dc.identifier.scopuseid_2-s2.0-0036172078en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0036172078&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume28en_US
dc.identifier.issue2en_US
dc.identifier.spage217en_US
dc.identifier.epage220en_US
dc.identifier.isiWOS:000173662600010-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridYeh, PC=7102670429en_US
dc.identifier.scopusauthoridGoins, KM=6603783756en_US
dc.identifier.scopusauthoridLai, WW=7402231098en_US
dc.identifier.issnl0886-3350-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats