Article: Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty

TitleUnusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty
Authors
KeywordsComplications
Intramedullary alignment guide
Total knee arthroplasty
Issue Date2001
PublisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/arthroplastyjournal
Citation
Journal Of Arthroplasty, 2001, v. 16 n. 2, p. 247-249 How to Cite?
AbstractThe few reported complications related to the use of a femoral intramedullary alignment guide in total knee arthroplasty include increase in perioperative bleeding and fat embolism. We report 3 patients suffering from an unusual complication, concerning trapping of the tibial locking pin inside the intramedullary canal of the femur secondary to the use of an intramedullary alignment guide. Methods of retrieving the locking pin from the medullary canal are discussed.
Persistent Identifierhttp://hdl.handle.net/10722/170033
ISSN
2021 Impact Factor: 4.435
2020 SCImago Journal Rankings: 2.766
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorYau, WPen_US
dc.contributor.authorNg, TPen_US
dc.contributor.authorChiu, KYen_US
dc.date.accessioned2012-10-30T06:04:52Z-
dc.date.available2012-10-30T06:04:52Z-
dc.date.issued2001en_US
dc.identifier.citationJournal Of Arthroplasty, 2001, v. 16 n. 2, p. 247-249en_US
dc.identifier.issn0883-5403en_US
dc.identifier.urihttp://hdl.handle.net/10722/170033-
dc.description.abstractThe few reported complications related to the use of a femoral intramedullary alignment guide in total knee arthroplasty include increase in perioperative bleeding and fat embolism. We report 3 patients suffering from an unusual complication, concerning trapping of the tibial locking pin inside the intramedullary canal of the femur secondary to the use of an intramedullary alignment guide. Methods of retrieving the locking pin from the medullary canal are discussed.en_US
dc.languageengen_US
dc.publisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/arthroplastyjournalen_US
dc.relation.ispartofJournal of Arthroplastyen_US
dc.subjectComplications-
dc.subjectIntramedullary alignment guide-
dc.subjectTotal knee arthroplasty-
dc.subject.meshAgeden_US
dc.subject.meshArthroplasty, Replacement, Kneeen_US
dc.subject.meshBone Nails - Adverse Effectsen_US
dc.subject.meshFemaleen_US
dc.subject.meshForeign Bodies - Complicationsen_US
dc.subject.meshHumansen_US
dc.subject.meshKnee Prosthesisen_US
dc.subject.meshMaleen_US
dc.subject.meshMiddle Ageden_US
dc.subject.meshOsteoarthritis - Surgeryen_US
dc.subject.meshPostoperative Complications - Etiologyen_US
dc.titleUnusual complication associated with femoral intramedullary alignment guide in total knee arthroplastyen_US
dc.typeArticleen_US
dc.identifier.emailYau, WP:peterwpy@hkucc.hku.hken_US
dc.identifier.emailChiu, KY:pkychiu@hkucc.hku.hken_US
dc.identifier.authorityYau, WP=rp00500en_US
dc.identifier.authorityChiu, KY=rp00379en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1054/arth.2001.19161en_US
dc.identifier.pmid11222904-
dc.identifier.scopuseid_2-s2.0-0035116374en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0035116374&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume16en_US
dc.identifier.issue2en_US
dc.identifier.spage247en_US
dc.identifier.epage249en_US
dc.identifier.isiWOS:000166879600019-
dc.publisher.placeUnited Statesen_US
dc.identifier.scopusauthoridYau, WP=7005822441en_US
dc.identifier.scopusauthoridNg, TP=24438193400en_US
dc.identifier.scopusauthoridChiu, KY=7202988127en_US
dc.identifier.issnl0883-5403-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats