File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: MIS and MS/MS performance of a new triple quadrupole-linear ion trap mass spectrometer for proteomics

TitleMIS and MS/MS performance of a new triple quadrupole-linear ion trap mass spectrometer for proteomics
Authors
Issue Date2002
Citation
Proceedings 50Th Asms Conference On Mass Spectrometry And Allied Topics, 2002, p. 181-182 How to Cite?
AbstractInfusion, LC/MS and data dependent LC/MS/MS experiments were carried out in parallel on the triple quadrupole-linear ion trap mass spectrometer for proteomics. Protein dynamic range was investigated with a digestion mixture of 12 standard proteins. A single peptide derived from β-lactoglobulin was detected in 2 separate LC/MS/MS experiments on the Q trap. It was observed that no peptides were derived from β-lactoglobulin that were sequenced in the parallel LC/MS/MS experiments.
Persistent Identifierhttp://hdl.handle.net/10722/168823

 

DC FieldValueLanguage
dc.contributor.authorKeshishian, Hen_US
dc.contributor.authorAddona, Ten_US
dc.contributor.authorClauser, Ken_US
dc.contributor.authorLeblanc, JCYen_US
dc.contributor.authorChu, IKen_US
dc.contributor.authorCarr, SAen_US
dc.date.accessioned2012-10-08T03:34:40Z-
dc.date.available2012-10-08T03:34:40Z-
dc.date.issued2002en_US
dc.identifier.citationProceedings 50Th Asms Conference On Mass Spectrometry And Allied Topics, 2002, p. 181-182en_US
dc.identifier.urihttp://hdl.handle.net/10722/168823-
dc.description.abstractInfusion, LC/MS and data dependent LC/MS/MS experiments were carried out in parallel on the triple quadrupole-linear ion trap mass spectrometer for proteomics. Protein dynamic range was investigated with a digestion mixture of 12 standard proteins. A single peptide derived from β-lactoglobulin was detected in 2 separate LC/MS/MS experiments on the Q trap. It was observed that no peptides were derived from β-lactoglobulin that were sequenced in the parallel LC/MS/MS experiments.en_US
dc.languageengen_US
dc.relation.ispartofProceedings 50th ASMS Conference on Mass Spectrometry and Allied Topicsen_US
dc.titleMIS and MS/MS performance of a new triple quadrupole-linear ion trap mass spectrometer for proteomicsen_US
dc.typeConference_Paperen_US
dc.identifier.emailChu, IK:ivankchu@hku.hken_US
dc.identifier.authorityChu, IK=rp00683en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.scopuseid_2-s2.0-2442682029en_US
dc.identifier.spage181en_US
dc.identifier.epage182en_US
dc.identifier.scopusauthoridKeshishian, H=7004437926en_US
dc.identifier.scopusauthoridAddona, T=6602857430en_US
dc.identifier.scopusauthoridClauser, K=6602911756en_US
dc.identifier.scopusauthoridLeBlanc, JCY=23039089800en_US
dc.identifier.scopusauthoridChu, IK=7103327484en_US
dc.identifier.scopusauthoridCarr, SA=7202363695en_US

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats